Cleaning the unit (shutting down)

A clean state is the best method of ensuring operation without
circumstances may any remaining coating material dry and harden in
the unit.
The cleaning agent used for cleaning (only with an igni tion point
Secure the spray gun, refer to the operating manual of the
spray gun.
Clean and remove tip.
For a standard tip, refer to Page 39, Section 12.2.
If a non-standard tip is installed, proceed according to the relevant
operating manual.
1. Remove suction hose from the coating material.
4. Pull the trigger of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container.
The container must be earthed in case of coating
materials which contain solvents.
Attention
Caution! Do not pump or spray into a container with
a small opening (bunghole)!
Refer to the safety regulations.
5. Immerse suction hose with return hose into a container with a
suitable cleaning agent.
6. Turn the pressure control knob into the blue zone - pulsating
pressure for unit cleaning.
(k circulation).
8. Pump a suitable cleaning agent in the circuit for a few
minutes.
10. Pull the trigger of the spray gun.
11. Pump the remaining cleaning agent into an open container
until the unit is empty.
GB
Attention
Attention
p spray).
suitable cleaning agent.
8.2
Clean the lter cartridge regularly.
A soiled or clogged high-pressure lter can cause a poor spray
pattern or a clogged tip.
1. Turn the pressure regulator knob into the black zone until it
5. Pull the lter cartridge (2) from the bearing spring (3).
6. Clean all the parts with the corresponding cleaning agent. If
p spray).
8. Place the bearing ring (5) against the bearing spring (3). Slide
9. Screw in lter housing (1) and tighten it as far as possible with
First of all pull out mains plug from socket.
Danger of short circult through panetrating water!
Never spray down the unit with high-pressure or
high-pressure steam cleaners.
Do not put the high-pressure hose into solvents.
Use only a wet cloth to wipe down the outside of the
hose.

Cleaning the high-pressure lter

stops (no pressure).
(k circulation).
Unplug the power plug from the outlet.
necessary, replace the lter cartridge.
the lter cartridge (2) over the bearing spring.
the strap wrench.
1
2
Cleaning the unit (shutting down)
5
3
4