11. FITTING THE FASCIA AND FIREFRONT
The fitting guide for the fascia is supplied with the fascia. Fit the fascia in accordance to
the fascia fitting guide.
A slotted firefront with a minimum free area as shown in figure 32 must always be
!
used.
Figure 32. Firefront minimum open area requirements (The
firefront may differ from that shown)
12.1 Recheck control settings.
Now that all the ceramic fuel effect and fascia are in position, the control operation
must be fully rechecked (See section 9.2).
12.2 Check for spillage.
A spillage check must be made before leaving the installed appliance with the
customer. Make this check with the appliance fully installed with the ceramic fuel
effects and fascia in position.
Close all doors and windows in the room containing the appliance.
!
Turn on the fan. Light the appliance and turn the control knob to "HIGH".
!
Leave the appliance on for five minutes.
!
INSTALLER GUIDE
12. CHECKS
Page 30