Take care not to damage the wiring loom
as the flue pipe is inserted through the
wall.
10. Connect the wiring loom at the
firebox end, the eight pin connector is
located on the lower right hand side of
the appliance. It is important that
approximately 250mm of slack cable
exists at the base of the firebox. This
slack is necessary to allow removal of
the electrical control unit in future
servicing.
8.2 Securing firebox to wall - cable
retention.
Figure 21.
See section 9.1 'Gas supply
connection'.
1. Assemble retention
cables into firebox.
2. Insert cables into
cable anchor points in
upper rear of firebox and
then tape together
adjoining edges of the
jacket as shown in figure
21.
3. Offer the firebox up to
the wall and feed the
retention cable through
the installed eyebolts.
4. Return the cables
through the holes
Figure 22.
provided at the lower
back of the firebox.
5. Assemble adjusters and tension as in figure 22.