Baxi GALLERY Series Installer's Manual page 36

Power flue inset gas fire
Hide thumbs Also See for GALLERY Series:
Table of Contents

Advertisement

Carefully withdraw the unit.
3. Detach the fan wiring loom connection.
(See figure 40).
4. The control unit can be pulled forward as
far as the slack in the mains lead will allow.
Do not stress the mains lead.
5. Unscrew the two screws on top of the
control box housing (See figure 41)
6. To remove the control box from its
housing hold it firmly and slowly slide it
clear. Be careful not to stress the wiring
7. When replacing the unit make sure that all
the leads are correctly and firmly connected (See
wiring diagram figure 27), and that no leads are
trapped.
14.8 To remove the mains lead connector.
1. Remove the electrical control components as in
points 1-6 section 14.7.
2. Make note of the wiring locations to the mains
lead connector. Disconnect the earth (green), live
(brown) and neutral (blue) leads from the
mains lead connector. Always hold the wire
terminals, never pull on the wires.
3. Unscrew the two mains lead connector
screws located on the outer housing (See
figure 42).
4. The mains lead connector has two tags that
hold it in place. There is a slot in the top of
the control box housing for access to the top
tag (See figure 43). Press the top and bottom
tags and slide the mains lead connector clear
of the control box housing.
5. Replace in reverse order. Make sure that all the leads are correctly and firmly
connected (See wiring diagram figure 27) and that no leads are trapped.
14.9 To remove the fan.
1. Where fitted remove the terminal guard basket, and then the weather shield and front
cover of the fan box (2 screws).
2. Disconnect the wiring loom connector at the fan motor casing.
3. Withdraw the fan unit from the fan box taking care not to snag or damage the wiring
INSTALLER GUIDE
Page 36
Figure 41.
Figure 42.
Figure 43.

Advertisement

Table of Contents
loading

This manual is also suitable for:

661 heat engine

Table of Contents