Working with the MICRO-circular saw
Sawing with the longitudinal stop
1. Release the clamping screw 1 (Fig. 5), set stop and again
retighten the clamping screw (the max. work piece width
amounts to 70 mm).
Sawing with the angle stop
1. Release the clamping screw 1 (Fig. 6), set the angles
according to the scale and retighten the clamping screw.
Then push the work piece lightly against the stop and
guide the stop along groove 2.
Overload display
Your electrical tool is equipped with an optical display that
signals when the device is too heavily loaded during work.
The LED item 13 (see fig. 1) lights up green once the device
is switched on in normal mode. When the device is over-
loaded (e.g. when the feed rate of the workpiece is too
high or the blade is worn etc.), the colour changes from
green to red. This is a sign that the device is in an operating
condition for which it is not designed. The mechanics and
electrics are very heavily loaded. This operating condition
should, therefore, be avoided. It is then advisable to work
with a lower feed rate, and possibly to replace worn saw
blades or to select a workpiece with reduced depth of
the cut etc.

Maintenance

Important
Pull out the mains plug prior to commencing all
maintenance and repair work.
Replacing the toothed belt
If the toothed belt becomes worn it is possible to change it
yourself. You can order replacement belts from the PROXXON
central service.
1. Remove mains plug.
2. Remove the saw blade.
3. Unscrew screws 2 and 4 (Fig. 7a).
4. Unscrew screws 3 and remove the base plate from the
transmission.
5. Release the threaded pin 7 (Fig. 7b) using 2 mm hexagon
key and pull out the shaft 6.
6. Release the motor screws 9 and remove the motor from
the transmission.
7. Remove the pulley 8 and insert a new toothed belt.
8. Install the pulley 8 with toothed belt in the transmission
casing.
9. Insert the toothed belts on the motor pinions and
reconnect the motor to the transmission
10. The rest of the assembly follows in reverse order.
Disposal
Please do not dispose of the device in domestic waste! The
device contains valuable substances that can be recycled. If
you have any questions about this, please contact your local
waste management enterprise or other corresponding
municipal facilities.

EC Declaration of Conformity

We declare with sole responsibility that this product fulfils the
requirements of the following EC guidelines:
EC Low voltage guideline 73/23/ EEC
DIN EN 61029 / 02.2001
IEC 61F(CO)86
EC Machine guideline 98/037/ EEC
DIN EN 61029 / 02.2001
IEC 61F(CO)86
EC Electromagnetic compatibility guideline
89/336/EEC
DIN EN 55014-1 / 09.2002
DIN EN 55014-2 / 08.2002
DIN EN 61000-3-2 / 12.2001
DIN EN 61000-3-3 / 05.2002
Dipl.-Ing. Jörg Wagner
PROXXON S.A.
Equipment Safety Division
- 7 -