Iecex Installation Drawing - 5331D - PR 5331 Series Manual

Table of Contents

Advertisement

LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5331D or 5334B the following must be observed. The module shall only be
Installed by qualified personnel who are familiar with the national and international laws, directives
and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
.
Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2, 20, 21, 22, M1
T4: -40 ≤ Ta ≤ 85ºC
T5: -40 ≤ Ta ≤ 60ºC
T6: -40 ≤ Ta ≤ 45ºC
Terminal: 3,4,5,6
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Revision date:
2013-06-03
14
IECEx Installation drawing
IECEx DEK 13.0035X
Ex ia IIC T4...T6 Ga
Ex ia IIIC Da
Ex ia I Ma
IEC 60079-0 : 2011, IEC 60079-11 : 2011, IEC 60079-26:2006
6
5
4
5331D
3
5334B
Terminal: 1,2
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10 μH
Ci: 1.0 nF
Version Revision
V1R0
5331V116-DE
WWW.PRELECTRONICS.COM
Non Hazardous Area
+
1
-
2
Barrier
5331QI01
0Page:
1/2

Advertisement

Table of Contents
loading

This manual is also suitable for:

5331d5332d5333d5335d5337d5343b

Table of Contents