Addressing

Every module on the Velbus system must have its own unique address. On modules with a rotary switch the address is
set using the 'ADDR' rotary switch (refer to the manual of the relevant module). On other modules e.g. the temperature
controller the address is set via the menu. These addresses may not be altered afterwards.
1. Press and hold the 'Menu' button for ±4 seconds to
open the extended menu.
T
Location
Conf i gur at i on
Mode
Menu
2. If necessary scroll through the extended menu using
the ↑ or ↓ button until the 'Configuration' item
appears
T
Location
Conf i gur at i on
Mode
Menu
3. Select the configuration menu with the → button.
T
Location
Language
Mode
Menu
4. Scroll through the configuration menu using the ↑ or
↓ button until the 'Address' item appears.
T
Location
Addr es s
Mode
Menu
32
VMB1TC Temperature controller manual – rev 5.0
5. Select the Address menu with the
Location
T
Addr es s __
Mode
Menu
6. Enter a unique address ('01'...'FE') using the ↑ or ↓
button.
T
Location
Addr es s 15
Mode
Menu
7. Confirm the address with the → button.
T
Location
Addr es s
Mode
Menu
8. Exit the menu with the T button.
Location
T
M o
0: 06
Mode
button.
Menu

Advertisement

Table of Contents
loading