Allocate A Relay Channel For Day Mode Of The Boiler - Velbus VMB1TC Manual

Temperature control module for the velbus system
Hide thumbs Also See for VMB1TC:
Table of Contents

Advertisement

Allocate a relay channel for day mode of the boiler

Some boilers can be set to day or night mode. In night mode, the boiler temperature is set approximately 10 degrees
lower. In our example, the boiler must be switched to day mode as soon as one of the sensor modules is in day or
comfort mode. This is accomplished through relay channel 1 of the first relay module.
1. Set all sensor modules in anti-freeze mode by
pressing the push button on the front panel
repeatedly until all LEDs are off.
2. Set the MODE and TIME1 rotary switches for
channel 1 of the first relay module to '0' (instant
control).
3. Remember the address of this relay module to
reinstate it later on.
4. Set the address of the first relay module to 'C1'. The
'MODE 1' LED flashes to indicate push button
learning mode (PBM).
Out1
Out2
Mode/
Mode/
Mode/
Mode/
ADDR.
ADDR.
Time2
Time2
Time2
Time2
0
0
0
Time1
Time1
Time1
0
0
0
Learn
CH1
CH2
CH3
Fx
:
OFF
x=CH1...4
Ex
: ON
:
:
9x :
Dx
TGL
Bx
TG1
ST1
Cx
:
PBM
Ax
:
TG2
8x
:
ST2
ON
Rx
Tx
Mode1
Out3
Out4
4 Channel relay module
Mode/
Time2
Time1
Mode/Time2
0
0
0:Moment
Start-stop
1:5s
Staircase
2:10s
Non-Retrigger
3:15s
Turn Off Delay
4:30s
Turn On Delay
5:1'
Trig Release
Time1
6:2'
Blink
0
0
7:5'
5'
8:10'
10'
9:15'
15'
A:30'
30'
CH4
B:1h
1h
C:2h
2h
VMB4RY
D:5h
5h
velleman
E:1day
1day
F:Toggle
Toggle
Mode2
Mode3
Mode4
VMB1TC Temperature controller manual – rev 5.0
5. Press and hold the third push button (DAY) of the first
temperature sensor until the relay is energised and
the red LED on the sensor module flashes.
6. Press and hold the third push button (DAY) of the
second temperature sensor until the relay is
energised and the red LED on the sensor module
flashes.
7. Press and hold the third push button (DAY) of the
third temperature sensor until the relay is energised
and the red LED on the sensor module flashes.
8. Set the address of the first relay module back to its
original value.