5. Operation

Operation of the device depends on the selected operating mode.
5.1

Functional description of the operating modes

5.1.1

"APP control"

Operating mode "APP control"
Start of charg-
Without RFID card:
ing process
„ Automatically after connection to the vehicle
„ Manually via the MENNEKES Charge APP.
With RFID card:
„ Authentication with valid RFID card
„ Manually via the MENNEKES Charge APP by selecting a valid RFID card.
Controlling the
Via the MENNEKES Charge APP:
charging pro-
„ Changing the charging current for the on-going charging process
cess
„ Interrupting the charging process (pause)
„ Continuing the charging process
„ Terminating the charging process.
By using the multifunction button:
„ Terminating the charging process.
The stop function with the multifunction button must be enabled during the setting-up process.
With RFID card:
„ Terminating the charging process with the same card used for starting the charging process.
Setting up the
f Make settings in the MENNEKES Charge APP
operating mode
Changing the
You can use the MENNEKES Charge APP "Configure Wallbox" to change to all operating modes con-
operating mode
figured during the setting-up process. The change of operating mode will apply for the on-going and
subsequent charging processes.
Behaviour after
The behaviour after a power failure is configured during setting-up process.
a power failure
„ Charging process is aborted (default setting when charging with authorization).
„ Charging process continues (default setting to charging without authorization).
In operating mode "APP control", all functions of other operating modes are disabled.
The charging capacity is then not controlled by time, network or an Energy Manager.