System health monitoring
The BMC implements system sensor monitoring feature. It could monitor voltage, temperature, and current
of critical components.
System Power Management
The BMC implements chassis power and resets functions for system administrators to control and manage
the system power behavior. These functions can be activated by sending the IPMI 2.0 compatible chassis
commands to the BMC over messaging interfaces. The following list summaries the supported functions.
Chassis power on
Chassis power off
Chassis power cycle
Chassis power reset
Chassis power soft
Server's power status report
Watchdog Timer
The BMC provides an IPMI 2.0 compatible watchdog timer which can prevent the system from system
hanging.
System Event Log (SEL)
A non-volatile storage space is allocated to store system events for system status tracking.
Serial over LAN (SOL)
IPMI 2.0 SOL is implemented to redirect the system serial controller traffic over an IPMI session. System
administrators are able to establish a SOL connection with a standard IPMI client, like IPMITOOL, to
remotely interact with serial text-based interfaces such as OS command-line and serial redirected BIOS
interfaces.
User Management
The BMC supports 9 IDs for IPMI user accounts. The maximum length of the username and password are 16
and 20 respectively, and the possible privilege levels are Callback, User, Operator, and Administrator.
Moreover, the account creator is allowed to enable/disable the user account at any time. If not specified,
the default user accounts are listed follows:
User Name
admin
Password
User Access
admin
Enabled
Password can be changed