Conrad Electronic FAZ 3000-SE-2 Operating Instructions Manual page 29

Radio controlled activation switch
Table of Contents

Advertisement

If activation is unsuccessful:
• If a window is not closed before leaving the house (that is, when a door/
window sends a 'contact open' signal) the activation switch will refuse to
arm the first time the contact is closed using the key switch/button.
Only by opening and then closing the contact again within 30 seconds can
the alarm base station be forced to 'externally armed' despite the open
magnet contact.
• Similarly, in case of a fault (sensor battery empty, sabotage contact open,
'alarm' appears on the alarm base station's LCD, etc.) the activation switch
will refuse to arm when the contact is first closed using the key switch/
button.
When the contact is closed, the green LED lights up and the red LED blinks;
the system does not change to the 'externally armed' status.
Only by opening and then closing the contact again within 30 seconds can
the alarm base station then be forced to 'externally armed' despite the fault.
Please note:
For safety reasons you should not force the alarm base station
to switch to the 'externally armed' state. Instead you should
determine the cause of the error on the alarm base station (look
at the LCD's display, call up the 'troubles
the sensors) and then remove it!
troubles' menu and check
troubles
troubles
troubles