Conrad Electronic FAZ 3000-SE-2 Operating Instructions Manual

Radio controlled activation switch

Advertisement

Quick Links

http://www.conrad.com
Imprint
These operating instructions are published by Conrad Electronic SE, Klaus-Conrad-
Str. 1, D-92240 Hirschau/Germany.
All rights reserved.
No reproduction (including translation) is permitted in whole or part e.g. photocopying,
microfilming or storage in electronic data processing equipment, without the express
100%
written consent of the publisher.
recycled
paper.
The operating instructions reflect the current technical specifications at the time of
print. We reserve the right to change the technical or physical specifications.
Bleached
without
© Copyright 2007 by Conrad Electronic SE. Printed in Germany.
chlorine.
OPERATING INSTRUCTIONS
FAZ 3000-SE-2
Radio controlled
activation switch
Item no. 75 03 38
This user manual belongs to this product. It contains important information
specific to its operation and handling. Please bear this in mind when
passing on the product to a third party.
Therefore keep this user manual for future reference!
A contents list can be found in the table of contents on page 2.
Version 01/07

Advertisement

Table of Contents
loading

Summary of Contents for Conrad Electronic FAZ 3000-SE-2

  • Page 1 Please bear this in mind when passing on the product to a third party. These operating instructions are published by Conrad Electronic SE, Klaus-Conrad- Str. 1, D-92240 Hirschau/Germany. Therefore keep this user manual for future reference! All rights reserved.
  • Page 2: Table Of Contents

    General information ..............10 b) Preparation ................... 11 c) Mounting and connection ............. 12 d) Registering the ‘FAZ 3000-SE-2’ with the alarm base station ... 14 e) Operating the ‘FAZ 3000-SE-2 ’ (in combination with a bolt switching contact) ......17 10.
  • Page 3: Introduction

    1. Introduction Dear customer, Thank you for purchasing this product. This product meets the requirements of both current national and European guidelines. In order to ensure continued fulfilment of legal requirements and safe operation of this product, we kindly ask you to carefully follow the instructions in this user manual! Please read the user manual completely and observe the safety and operation instructions before using the product!
  • Page 4: Prescribed Use

    2. Prescribed use The radio controlled activation switch ‘FAZ 3000-SE-2’ is only suitable for use with the wireless alarm system ‘FAZ 3000’. Connection points for external switches and buttons are found inside the activation switch (for example, a bolt switching contact), with which the ‘FAZ 3000-Z’...
  • Page 5: Explanation Of Icons

    4. Explanation of icons The icon with a lightning flash in a triangle is used to alert you to potential personal injury hazards such as electric shock. The icon with an exclamation mark in a triangle points to important information in this user manual that must be observed. ...
  • Page 6: B) Batteries And Rechargeable Batteries

    • The product is only approved for installation and operation in dry and closed indoor rooms. Make sure that the product does not get damp or wet. • This product is not a toy and should be kept out of the reach of children. •...
  • Page 7: Functionality

    6. Functionality The radio controlled activation switch ‘FAZ 3000-SE-2’ is used to arm the ‘FAZ 3000-Z’ alarm base station via various switches/buttons.  This allows the alarm control centre to be activated or deactivated simply by closing the entrance door – by means of a bolt switching contact in the door’s strike plate –...
  • Page 8: Opening The Casing Of The 'Faz 3000-Se-2

    7. Opening the casing of the ‘FAZ-SE’ • Open the casing; the two casing halves are secured by two catches (‘A’ in figure 1 below). Using a flat-headed screw driver, carefully press the two catches about a millimetre inwards, until you are able to open the casing: First press one catch inwards and pull the casing approx.
  • Page 9: Connections And Control Elements

    8. Connections and control elements A ‘KL1’ connection for the bolt switching contact or switch/button B ‘KL2’ connection for two external LEDs to indicate ‘armed’ or ‘disarmed’ status C ‘KL3’ connection for external sabotage contact, for example, for the external cas- ing of a key switch (if this connection is used the jumper must be removed!)
  • Page 10: Installation With Bolt Switching Contact

    (‘disarmed’). Bolt switching contacts are available as simple normally open contacts or as change-over switches. Both versions can be used with the ‘FAZ 3000-SE-2’ activation switch, as only the normally open contact command is applied.
  • Page 11: B) Preparation

    b) Preparation • Lead the connection cable from the bolt switching contact to the installation location selected for the activation switch. Lay the cables so that they are not accessible from the outside. Lay the cables in-wall or in a suitable steel tube.
  • Page 12: C) Mounting And Connection

    c) Mounting and connection • If you intend to secure the activation switch with screws, you may need to first drill a hole (6mm) and insert a suitable dowel. When drilling or fastening screws be careful not to acciden- tally damage any power supply lines, gas or water pipes as this could pose a life-threatening danger! By securing the activation switch with screws, you can prevent it from being easily removed from the wall (sabotage protection).
  • Page 13 • The LEDs are connected as shown in figure 5. Make sure that you connect the red and green LEDs correctly, so that they light up like the LEDs that are already built-in. Terminals from KL2: Left connection: GND/earth Middle connection: + for red LED Right connection: + for green LED...
  • Page 14: D) Registering The 'Faz 3000-Se-2' With The Alarm Base Station

    Registering the ‘FAZ 3000-SE-2’ with the alarm base station  To register an activation switch the alarm base station must first be set to receive radio signals. Make sure that you also read the user manual of the ‘FAZ 3000-Z’ alarm base station.
  • Page 15 • Now go to the activation switch that you wish to register with the alarm base station.  After installing the activation switch the casing of the device is still open, the batteries are not yet inserted. • Insert 3 AAA batteries, making sure that the polarity is correct.
  • Page 16 • Return to the alarm base station. The LCD’s rem. sw. display has changed. See the figure on the right. Here, ‘1 1 1 1 1 ’ is the number of the activation switch (a maximum of four are possible). •...
  • Page 17: E) Operating The 'Faz 3000-Se-2' (In Combination With A Bolt Switching Contact)

    Operating the ‘FAZ 3000-SE-2’ (in combination with a bolt switching contact) The ‘FAZ 3000-SE-2’ activation switch has two buttons and two LEDs: • Button ‘int. armed / disarmed’ • Button ‘ext. armed’ • Red LED ‘armed’ • Green LED ‘disarmed’...
  • Page 18 To switch the state of an alarm base station from ‘internally armed’ to ‘disarmed’, briefly press the ‘int. armed / disarmed’ button on the ‘FAZ 3000-SE-2’ activation switch. The red ‘armed’ LED briefly lights up. Afterwards the green ‘int. armed/ disarmed’ LED lights up for approx.
  • Page 19 Similarly, in case of a fault (sensor battery empty, sabotage contact open, ‘alarm’ appears on the alarm base station’s LCD, etc.) the activation switch will refuse to arm when the bolt switching contact is first closed.  This is indicated as soon as the ‘ext. armed’ button is pressed: The green LED lights up for 30 seconds and the red LED blinks.
  • Page 20: Operation Using A Key-Operated Switch/Button

    10. Operation using a key-operated switch/ button a) General information A key switch or key button may be installed outside next to the entrance door and allows the alarm base station to be armed (‘externally armed’) and disarmed from outside. The key switch or button must be equipped with a change-over switch or button (‘1 x turn’).
  • Page 21 • The activation switch should be installed in a dry indoor area (not in a damp cellar or a bathroom, for example). • Choose a secured area so that intruders cannot quickly tamper with the device. The installation location should neither be immediately visible from outside the house nor from within the house.
  • Page 22: C) Mounting And Connection

    c) Mounting and connection • If you intend to secure the activation switch with screws, you may need to first drill a hole (6mm) and insert a suitable dowel. When drilling or fastening screws be careful not to acciden- tally damage any power supply lines, gas or water pipes as this could pose a life-threatening danger! By securing the activation switch with screws, you can prevent it from being easily removed from the wall (sabotage protection).
  • Page 23 • The LEDs are connected as shown in figure 10. Make sure that you connect the red and green LEDs correctly, so that they light up like the LEDs that are already built-in. Terminals from KL2: Left connection: GND/earth Middle connection: + for red LED Right connection: + for green LED...
  • Page 24: D) Registering The 'Faz 3000-Se-2' With The Alarm Base Station

    Registering the ‘FAZ 3000-SE-2’ with the base station  To register an activation switch the alarm base station must first be set to receive radio signals. Make sure that you also read the user manual of the ‘FAZ 3000-Z’ alarm base station.
  • Page 25 • Now go to the activation switch that you wish to register with the alarm base station.  After installing the activation switch the casing of the device is still open, the batteries are not yet inserted. • Insert 3 AAA batteries, making sure that the polarity is correct.
  • Page 26 • Return to the alarm base station. The LCD’s rem. sw. display has changed. See the figure on the right. Here, ‘1 1 1 1 1 ’ is the number of the activation switch (a maximum of four are possible). •...
  • Page 27: E) Operating The 'Faz 3000-Se-2' (In Combination With A Key Switch/Button)

    Operating the ‘FAZ 3000-SE-2 ’ (in combination with a key switch/button) The ‘FAZ 3000-SE-2’ activation switch has two buttons and two LEDs: • Button ‘int. armed / disarmed’ • Button ‘ext. armed’ • Red LED ‘armed’ • Green LED ‘disarmed’...
  • Page 28 To switch the state of an alarm base station from ‘internally armed’ to ‘disarmed’, briefly press the ‘int. armed / disarmed’ button on the ‘FAZ 3000-SE-2’ activation switch. The red ‘armed’ LED briefly lights up. Afterwards the green ‘int. armed / disarmed’ LED lights up for approx.
  • Page 29 If activation is unsuccessful: • If a window is not closed before leaving the house (that is, when a door/ window sends a ‘contact open’ signal) the activation switch will refuse to arm the first time the contact is closed using the key switch/button. Only by opening and then closing the contact again within 30 seconds can the alarm base station be forced to ‘externally armed’...
  • Page 30: Opening The Casing Of Activation Switch, Replacing The Batteries

    11. Opening the casing of activation switch, replacing the batteries  Before opening the activation switch’s casing, the activation switch must be set to maintenance mode. Otherwise the alarm base station immediately sets off the sabotage alarm when the casing is opened. Proceed as follows: •...
  • Page 31 Once the new batteries have been inserted the sensor’s LED briefly blinks once. The radio connection to the alarm base station has been established and checked. Instead of changing the batteries, you could, for example, change the wiring. • Once you have finished replacing the batteries or made changes to the wiring, close the sensor’s casing again.
  • Page 32: Maintenance And Cleaning

    12. Maintenance and cleaning The product requires no servicing except for battery replacement. Any repairs should be carried out by a skilled technician or a professional workshop. Clean the product with a soft, clean, dry and lint-free cloth. To remove heavier dirt, use a cloth which is slightly moistened with lukewarm water.
  • Page 33: Information On The Range

    14. Information on the range Ranges and interference • The activation switch uses the 868MHz range, which is also used by other radio services. Therefore devices that operate on the same or neighbouring frequencies may restrict both its operation and its range. •...
  • Page 34: Technical Specifications

    15. Technical specifications • Connections: ....1 x Turn, for key switch/button 1 x Sabotage (for key switch/button casing) 1 x LED red (activated) 1 x LED green (deactivated) • Batteries: ......3 x AAA • Dimensions: ....53mm x 163mm x 24mm (W x H x D) •...
  • Page 35: Brief Instructions

    • Exit the maintenance mode of the alarm base station 17. Declaration of conformity (DOC) We, Conrad Electronic, Klaus-Conrad-Straße 1, 92240 Hirschau (Germany), hereby declare that this product complies with the fundamental requirements and other relevant regulations of directive 1999/5/EC.

Table of Contents