Radio controlled activation switch
Table of Contents

Advertisement

To switch the state of an alarm base station from 'internally armed'
to 'disarmed', briefly press the 'int. armed / disarmed' button on
the 'FAZ 3000-SE-2' activation switch. The red 'armed' LED briefly
lights up. Afterwards the green 'int. armed / disarmed' LED lights
up for approx. 30 seconds.
Of course you can also use the 'disarmed' button on the alarm
base station or a 'FAZ 3000-FB' remote control to switch the alarm
base station to 'disarmed'!
Description of the 'ext. armed' button
The 'ext. armed' button has no function when used in connection with a key
switch/button. Its function is then assumed by the key switch/button.
Key switch/button function description
In the case of a key switch the respective switch of the internal change-over
switch remains permanently closed. The key may be withdrawn in either of the
two possible positions.
The key-operated button, by contrast, closes the contact when turned to the
right or the left position, but can only be withdrawn when in the middle position
(that is, when no contact is engaged).
The function in connection with the activation switch is identical
in both cases.
• When switched, either by switch or button, to the 'armed' position (contact
'armed' and middle contact closed) the alarm base station is switched to
'externally armed'.
• When switched, either by switch or button, to the 'disarmed' position (contact
'disarmed' and middle contact closed) the alarm base station is switched
to 'disarmed'.
The alarm base station confirms the respective change of status with a signal
tone, the red or green LED lights up to indicate the status and goes out again
after 30 seconds.