Demagnetization of the secondary sections
Disposal companies specialized in demagnetization use special disposal furnaces. The
insides of the disposal furnace consist of non-magnetic material.
The secondary sections are put in the furnace in a solid, heat-resistant container (such as a
skeleton container) made of non-magnetic material and left in the furnace during the entire
demagnetization procedure. The temperature in the furnace must be at least 300 °C during a
holding time of at least 30 minutes.
Escaping exhaust must be collected and made risk-free without damaging the environment.
A.3.2.3

Disposal of packaging

Packaging materials and disposal
The packaging and packing aids we use contain no problematic materials. With the
exception of wooden materials, they can all be recycled and should always be disposed of
for reuse. Wooden materials should be burned.
Only recyclable plastics are used as packing aids:
● Code 02 PE-HD (polyethylene)
● Code 04 PE-LD (polyethylene)
● Code 05 PP (polypropylene)
● Code 04 PS (polystyrene)
A.4

Terminal markings according to EN 60034-8:2002

Terminal markings according to EN 60034-8:2002
With the EN 60034-8:2002 standard, the terminal markings for electrical connections have
changed. The following table shows the changes that are relevant for the motors described
here.
Table A- 1
Old designation
New designation
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Terminal markings according to EN 60034-8
KTY 84 or Pt1000
(Temp-F)
2T1⊕ / 2T1⊝
+1R1 / –1R1
A.4 Terminal markings according to EN 60034-8:2002
Appendix
PTC
(Temp-S)
1T1 / 1T2
1TP1 / 1TP2