Siemens SIMOTICS L-1FN3 Configuration Manual page 186

Linear motors peak and continuous load motors
Hide thumbs Also See for SIMOTICS L-1FN3:
Table of Contents

Advertisement

Technical data and characteristics
6.2 Data sheets and characteristics
1FN3050-2NE00-0xAx
Technical data
Primary section precision cooler data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop
Secondary section cooling data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop per meter of heatsink profile
Pressure drop per combi distributor
Pressure drop per coupling point
184
Designation
Q
P,P,MAX
P ,P,MIN
Δp
P,P
Q
S,MAX
S ,MIN
Δp
S
Δp
KV
Δp
KS
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Unit
Value
kW
0.00833
l/min
2.1
bar
0.0772
kW
0.0279
l/min
2.1
bar
0.0286
bar
0.119
bar
0.0877