A rule of thumb for selecting the primary section is as follows:
In this particular example, the quotient F
duty cycle, the peak load motor has sufficient reserves with its maximum force F
effective force F
Without taking other decision-making criteria into account, the peak load motor 1FN3150-
4WC00-0BA1 is the most suitable for the specified duty cycle and is therefore used for the
following calculations.
Specifying the number of secondary sections
Type of secondary section
Based on the article number, a search is made for the appropriate secondary section for
primary section 1FN3150-4WC00-0BA1. It has the order designation 1FN3150-4SA00-0AA0.
Length of the secondary section track and number of secondary sections
l
Spur
Number = l
l
P,AKT
l
= 120 mm (see motor data sheet 1FN3150-4WC00-0BA1)
S
⇒ l
Spur
⇒ Number of secondary sections = 6
Selecting the power module
The selected peak load motor has the following data:
F
MAX
F
= 1350 N
N
I
MAX
I
= 14.3 A
N
A suitable power module for this data is selected from the relevant catalog.
1FN3 linear motors
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
is substantially below the rated force F
eff
= l
+ s
P,AKT
MAX
/ l
Spur
S
= 420 mm (see motor data sheet 1FN3150-4WC00-0BA1)
= 420 mm + 260 mm = 680 mm
= 3300 N
= 38.2 A
/ F
is equal to 2.1. For peak force F
L,max
eff
of the continuous load motor.
N
Configuration
5.3 Examples
of the
L,MAX
. The