Technical data and characteristics
6.2 Data sheets and characteristics
1FN3450-1NB50-0xAx
Technical data
Primary section precision cooler data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop
Secondary section cooling data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop per meter of heatsink profile
Pressure drop per combi distributor
Pressure drop per coupling point
304
Designation
Q
P,P,MAX
P ,P,MIN
Δp
P,P
Q
S,MAX
S ,MIN
Δp
S
Δp
KV
Δp
KS
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Unit
Value
kW
0.0182
l/min
3.5
bar
0.19
kW
0.0609
l/min
3.5
bar
0.0724
bar
0.324
bar
0.237