Technical data and characteristics
6.2 Data sheets and characteristics
Data sheet of 1FN3600-2NE50-0xAx
1FN3600-2NE50-0xAx
Technical data
General conditions
DC-link voltage
Water cooling flow temperature
Rated temperature
Data at the rated point
Rated force
Rated current
Maximum velocity at rated force
Rated power loss
Limit data
Maximum force
Maximum current
Maximum velocity at maximum force
Maximum electric power drawn
Static force
Stall current
Physical constants
Force constant at 20 °C
Voltage constant
Motor constant at 20 °C
Motor winding resistance at 20 °C
Phase inductance
Attraction force
Thermal time constant
Pole width
Mass of the primary section
Mass of the primary section with precision cooler
Mass of a secondary section
Mass of a secondary section with heatsink profiles
Primary section main cooler data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Coolant temperature rise
Pressure drop
Primary section precision cooler data
Maximum dissipated thermal output
Recommended minimum volume flow rate
Pressure drop
390
Designation
U
DC
T
VORL
T
N
F
N
I
N
v
MAX,FN
P
V,N
F
MAX
I
MAX
v
MAX,FMAX
P
EL,MAX
F
*
0
I
*
0
k
F,20
k
E
k
M,20
R
STR,20
L
STR
F
A
t
TH
τ
M
m
P
m
P,P
m
S
m
S,P
Q
P,H,MAX
P ,H,MIN
ΔT
P,H
Δp
P,H
Q
P,P,MAX
P ,P,MIN
Δp
P,P
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
Unit
Value
V
600
°C
35
°C
120
N
3460
A
64.2
m/min
460
kW
2.06
N
5870
A
135
m/min
259
kW
34.4
N
2490
A
45.4
N/A
54.9
Vs/m
18.3
N/W
91.5
0.5
Ω
0.12
mH
2.78
N
11600
s
180
mm
23
kg
30.4
kg
32
kg
4.6
kg
5
kW
1.83
l/min
4.5
K
5.85
bar
0.489
kW
0.0541
l/min
4.5
bar
0.829
1FN3 linear motors