Mechanical properties
3.1 Cooling
Coolant intake temperature
NOTICE
Corrosion in the machine
Condensation can lead to corrosion in the machine.
• Select the intake temperatures so that no condensation forms on the surface of the
The rated motor data refer to operation at a coolant intake temperature of 35 °C. If the intake
temperature is different, the continuous motor current changes as shown below.
Note
For a cooler intake temperature of < 35 °C, the possible continuous motor current is greater
than the rated current I
Larger cable cross-sections may be required. This means that you must take into account
the rated current of the cables.
The following diagram shows the dependency of the relative continuous primary section
current (I
to friction and eddy currents are ignored here.
Figure 3-9
68
motor. Condensation does not form if the intake temperature T
ambient temperature or corresponds to the ambient temperature.
.
N
/ I
) * 100 on the water intake temperature in the cooling system. Losses due
Primärteil
N
Influence of the coolant intake temperature
is higher than the
VORL
Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
1FN3 linear motors