MAINTENANCE INSTRUCTIONS
PARAMETER 20 - CENTRAL HEATING MAXIMUM SET POINT
This parameter is used to set the central heating maximum user
set point.
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4)
5.
Use '+' and '-' buttons (D.H.W temperature setting) to modify the value
of the parameter within the prescribed limits
degrees):
min = 104°F
max = 190°F
6.
Press mode selection button
parameter operative
7.
To exit from the parameters menu, press simultaneously 'i' and 'R'
buttons
PARAMETER P21 – D.H.W. MAXIMUM SET POINT
This parameter is used to set the D.H.W maximum user set point.
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4)
5.
Use '+' and '-' buttons (D.H.W temperature setting) to modify the value
of the parameter within the prescribed limits
degrees):
min = 113°F
max = 167°F
6.
Press mode selection button
parameter operative
7.
To exit from the parameters menu, press simultaneously 'i' and 'R'
buttons
PARAMETER P22 – ∆T SET POINT T° FLOW / T° RETURN
(not applicable)
This parameter is used to set the delta value between the flow and
the return temperature.
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4)
5.
Use '+' and '-' buttons (D.H.W temperature setting) to modify the value
of the parameter within the prescribed limits
degrees):
00 = Disabled (default)
min = 10 °C
max = 40 °C
6.
Press mode selection button
parameter operative
7.
To exit from the parameters menu, press simultaneously 'i' and 'R'
buttons
–
.
.
.
.
.
.
(