REGULATION INSTRUCTIONS
PARAMETER P03 – SETS THE CENTRAL
HEATING TEMPERATURE
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4).
5. Use '
' and '
modify the value of the parameter:
00 = standard (95-185°F)
01 = reduced (77-113°F) for under-floor heating
6. Press mode selection button '
parameter operative.
7. To exit from the parameters menu, press simultaneously '
'
' buttons.
PARAMETER P04 – HEATING OUTPUT RISING TIME
This parameter is used to set the time the boiler takes to reach the
maximum power set, during the starting up.
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4).
5. Use '
' and '
modify the value of the parameter:
00 = 0 seconds (disabled)
01 = 50 seconds (default)
02 = 100 seconds
03 = 200 seconds
04 = 400 seconds
6. Press mode selection button '
parameter operative.
7. To exit from the parameters menu, press simultaneously '
'
' buttons.
PARAMETER P05 – WATER HAMMER PREVENTION FUNCTION
Activating this function, the D.H.W contact is delayed for 2 seconds.
To enter the parameters menu, follow the previously described procedure
(see paragraph 5.2 'Accessing the parameters menu' - steps 1-4).
5. Use '
' and '
modify the value of the parameter:
00 = Off
01 = On
6. Press mode selection button '
parameter operative.
7. To exit from the parameters menu, pres simultaneously
' buttons (D.H.W temperature setting)
' to confirm and to render the new
' buttons (D.H.W temperature setting)
' to confirm and to render the new
' buttons (D.H.W temperature setting)
' to confirm and to render the new