Fitting an expansion joint ......................... 20 Installing unpressurised inlet tanks ....................... 20 Electrical connection ............................ 21 5.6.1 Sizing the power cable ........................ 21 5.6.2 Connecting the external dry running protection device (optional) .......... 21 Commissioning/Start-up/Shutdown.................... 23 Commissioning/Start-up .......................... 23 KSB Delta Solo Compact 3 of 40...
Page 4
Setting the pre-charge pressure...................... 30 Trouble-shooting.......................... 31 Related Documents .......................... 33 10.1 General assembly drawings/exploded views with list of components ............ 33 10.1.1 KSB Delta Solo Compact MVP ...................... 33 EU Declaration of Conformity ...................... 34 Certificate of Decontamination...................... 35 Commissioning Report......................... 36 Index ..............................
Dry running protection Dry running protection devices prevent the pump from being operated without the fluid to be handled, which would result in pump damage. Efficiency class to IEC 60034-30: 3 = Premium Efficiency (IE = International Efficiency) KSB Delta Solo Compact 5 of 40...
The serial number uniquely describes the product and is used as identification in all further business processes. In the event of damage, immediately contact your nearest KSB service facility to maintain the right to claim under warranty. 1.2 Software changes The software has been specially created for this product and thoroughly tested.
In conjunction with one of the signal words this symbol indicates a hazard involving electrical voltage and identifies information about protection against electrical voltage. Machine damage In conjunction with the signal word CAUTION this symbol indicates a hazard for the machine and its functions. KSB Delta Solo Compact 7 of 40...
If required, the operator can commission the manufacturer/supplier to train the personnel. ▪ Training on the pressure booster system must always be supervised by specialist technical personnel. KSB Delta Solo Compact 8 of 40...
▪ Make sure the pressure booster system cannot be accessed by unauthorised persons (e.g. children). ▪ Prior to opening the device, pull the mains plug and wait for at least 10 minutes. KSB Delta Solo Compact 9 of 40...
C1 specifications: This product can produce high-frequency interference emissions that may necessitate targeted interference suppression measures in a residential or office environment. An EMC plan must be devised. KSB Delta Solo Compact 10 of 40...
– Part 4-5: Testing and measurement techniques – Surge immunity test ▪ EN 61000-4-6: Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields KSB Delta Solo Compact 11 of 40...
1. On transfer of goods, check each packaging unit for damage. 2. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the supplying dealer and the insurer about the damage in writing immediately.
2. Separate and sort the pump materials, e.g. by: - Metals - Plastics - Electronic waste - Greases and other lubricants 3. Dispose of materials in accordance with local regulations or in another controlled manner. KSB Delta Solo Compact 13 of 40...
Page 14
Contact your local waste disposal partner for returns. If the used electrical or electronic equipment contains personal data, the operator is responsible for deleting it before the equipment is returned. KSB Delta Solo Compact 14 of 40...
4 Description 4 Description 4.1 General description ▪ Pressure booster system 4.2 Designation Example: KSB Delta Solo Compact 1/0606 MVP Table 8: Designation key Code Description KSB Delta Solo Type series Compact Number of pumps Pump size Number of pump stages...
▪ Colour LED indicating lack of water (red) ▪ 2 volt-free contacts on terminals are provided for reporting warnings and alerts. 4.5 Configuration and function Fig. 2: Configuration Swing check valves Frequency inverter Baseplate Membrane-type accumulator KSB Delta Solo Compact 16 of 40...
For dimensions and weights please refer to the type series booklet of the pump (set). 4.9 Terminal wiring diagram For the terminal assignment refer to the circuit diagram. 4.10 Potential equalisation The power cable has an earthed plug for potential equalisation. KSB Delta Solo Compact 17 of 40...
▷ Use a concrete of compressive strength class C12/15 which meets the requirements of exposure class XC1 to EN 206-1. ▷ The mounting surface must be set, flat, and level. ▷ Observe the weights indicated. KSB Delta Primo VC: +30 °C KSB Delta Solo Compact 18 of 40...
The anti-vibration mounts of the pressure booster system provide adequate insulation against solid-borne noise. Thanks to level-adjustable feet (KSB accessory) the pressure booster system can also be installed in a horizontal position on uneven floors. All structural work required has been checked and prepared in accordance with the dimensions in the outline drawing.
Install the closed tank (under atmospheric pressure) available from us as an accessory as described in the installation instructions supplied with the tank. KSB Delta Solo Compact 20 of 40...
1. Connect the cores of the external dry running protection device at pin 2 and pin 4 of the M12 plug. The contact must be a normally closed contact. N.C. Fig. 4: Connecting the external dry running protection equipment KSB Delta Solo Compact 21 of 40...
Page 22
5 Installation at Site Table 9: Pin assignment of the M12 plug Item Status Function Not used Normally closed contact Connected to DI2 Not used Normally closed contact Connected to GND KSB Delta Solo Compact 22 of 40...
5. Close the discharge-side shut-off element slowly and check whether the pressure booster system stops. 6. Run the pump again, with the discharge-side shut-off element open, and loosen the vent plug to let any remaining air escape. 7. Then re-tighten the vent plug firmly. KSB Delta Solo Compact 23 of 40...
6.4 Shutdown NOTE As long as the pressure booster system is out of operation, water is supplied directly at p through the pressure booster system. KSB Delta Solo Compact 24 of 40...
Page 25
It is advisable to then close the pump nozzles (e.g. with plastic caps or similar). 3. Oil or grease all exposed machined parts and surfaces of the pressure booster system to protect them against corrosion. KSB Delta Solo Compact 25 of 40...
7.1 Design of the frequency inverter The frequency inverter is motor-mounted and self-cooling. Its display and control panel feature the following: Fig. 5: KSB Delta Compact display and control panel Red LED indicating stand-by The red stand-by LED is lit when the motor is energised.
Page 27
▪ If the Set LED (5) flashes, press the Plus button or Minus button until the Set LED lights up continuously. ▪ Set the pressure by pressing the Plus button or Minus button as required. KSB Delta Solo Compact 27 of 40...
Function of pressure booster system not guaranteed! ▷ Regularly service the pressure booster system. ▷ Prepare a maintenance schedule for the pressure booster system, with special emphasis on lubricants, shaft seals and pump couplings. KSB Delta Solo Compact 28 of 40...
▪ For any work on the pump (set) observe the operating manual of the pump (set). ▪ In the event of damage you can always contact KSB Service . ▪ A regular maintenance schedule will help avoid expensive repairs and contribute to trouble-free, reliable operation with a minimum of maintenance expenditure and work.
5. Fit the protective cap of the membrane-type accumulator valve. Filling the membrane-type accumulator 1. Remove and store the protective cap of the membrane-type accumulator valve. 2. Add nitrogen through the valve. 3. Fit the protective cap of the membrane-type accumulator valve. KSB Delta Solo Compact 30 of 40...
Increase flow rate of in suction line too low water meter. System-side filter clogged Clean filter or check filter for obstruction. If required, replace filter. Shut-off valve in outlet Open both shut-off and/or inlet closed valves. KSB Delta Solo Compact 31 of 40...
Page 32
The alarm value for minimum pressure has been reached. (Determine the cause of the minimum pressure falling below the alarm value). Rapid flashing The digital inputs have been disconnected. without any pauses KSB Delta Solo Compact 32 of 40...
10 Related Documents 10 Related Documents 10.1 General assembly drawings/exploded views with list of components 10.1.1 KSB Delta Solo Compact MVP 743.90 79-2 742.01 742.02 Fig. 6: KSB Delta Solo Compact MVP Table 15: List of components Part No. Description Part No.
2401 LJ Alphen aan den Rijn (The Netherlands) The manufacturer herewith declares that the product: KSB Delta Solo Compact (MVP) Serial number: 06/2018 0000000-0001 - 52/2020 9999999-9999 ▪ is in conformity with the provisions of the following Directives as amended from time to time: –...
We confirm that the above data and information are correct and complete and that dispatch is effected in accordance with the relevant legal provisions....................................Place, date and signature Address Company stamp Required fields KSB Delta Solo Compact 35 of 40...
13 Commissioning Report 13 Commissioning Report The pressure booster system specified below has been commissioned today by the undersigned, authorised KSB Service who created this report. Pressure booster system details Type series ............................Size ............................Serial number ............................Order No.