Sony HDCU-900 Series Installation And Maintenance Manual page 27

Hd camera control unit
Hide thumbs Also See for HDCU-900 Series:
Table of Contents

Advertisement

. S810 (RET LB ASPECT SEL)
This switch is valid when S814 on the RC-86 board is
set to LOC.
When S809 on the RC-86 board is set to letter box,
select the aspect ratio of the letter box.
S810-1, -2 : RET1
S810-3, -4 : RET2
S810-5, -6 : RET3
S810-7, -8 : RET4
S810-1, -3, -5, -7
S810-2, -4, -6, -8
ON
ON
ON
OFF
OFF
ON
OFF
OFF
Factory setting : 16 : 9
. S811-1, 2 (CB SEL)
Select the color bar signal to be output from the SD
signal output.
S811-1
S811-2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Factory setting : 100 % & 75 %-CB (non-split)
. S811-3 (CB SEL)
When S811-1, -2 on the RC-86 board are set to OFF,
select the same color bar as HD to be output from the SD
signal output.
ON : Selected
OFF : Not selected
Factory setting : OFF
. S811-4 to 8
Factory use only
Factory setting : All OFF
. S812-1 (SYNC SEL)
Select the SYNC signal to be output to the SYNC
OUTPUT connector on the DIF-102 board.
ON : SD SYNC
OFF : HD SYNC
Factory setting : OFF
HDCU-900 IMM
Aspect ratio
13 : 9
16 : 9
14 : 9
_
Color bar
100 %-CB (non-split)
100 % & 75 %-CB (non-split)
75 %-CB (non-split)
Pseudo SMPTE-CB
1-5. Settings of Switches and Controls on Boards
. S812-2 (SETUP SEL)
Select whether SETUP is added to the VBS signal of
PIX/WFM OUT.
ON : Added
OFF : Not added
Factory setting : OFF
. S812-3 to 8
Factory use only
Factory setting : All OFF
. S813 (LB ASPECT SEL)
This switch is valid when S805 on the RC-86 board is
set to LOCAL.
When S806 on the RC-86 board is set to letter box,
select the aspect ratio of the letter box.
→ 13 : 9
13 : 9
→ 14 : 9
14 : 9
→ 16 : 9
16 : 9
Factory setting : 16 : 9
. S814 (RET VIDEO ASPECT REMOTE/LOCAL)
Set whether the aspect ratio of the RETURN VIDEO
signal is selected using MSU.
REM : Set using MSU.
LOC : Depends on the settings of S809 and S810 on
the RC-86 board.
Factory setting : REM
Controls
. RV350 (WFM GAIN)
Adjust the level of the signal for the waveform monitor.
. RV351 (PIX GAIN)
Adjust the level of the signal for the picture waveform
monitor.
. RV352 (STAIR STEP POSITION)
Set the position to display the STAIR CASE signal.
. RV353 (STAIR STEP LEVEL)
Set the interval of the STAIR CASE signal.
1-19 (E)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents