Sony HDCU-900 Series Installation And Maintenance Manual page 13

Hd camera control unit
Hide thumbs Also See for HDCU-900 Series:
Table of Contents

Advertisement

WF REMOTE (D-sub 15-pin, Female)
8
1
15
9
_ _ _ _ _ EXT VIEW _ _ _ _ _
*4
Recall system
No.
Signal
Specifications
1
NC
No connection
2
NC
No connection
3
NC
No connection
4
NC
No connection
5
RECALL2 (G)
LOW ACTIVE
6
RECALL3 (B)
7
RECALL1 (R)
8
RECALL4 (SEQ)
9
GND
10
NC
No connection
11
NC
No connection
12
RECALL5 (ENC)
LOW ACTIVE
13
RECALL6 (R+B)
14
RECALL7 (R+G)
15
RECALL8 (G+B)
1-2. Connectors and Cables
*4
1735HD/1730HD
No.
Signal
Specifications
1
LINE/FIELD
LINE :
5 V dc
FIELD :
0 V dc
2
FOUR OUT
FOUR :
0 V dc
3
ONE/TWO OUT
ONE :
5 V dc
TWO :
0 V dc
4
REMOTE 1 OUT
REMOTE : 5 V dc
ENB :
0 V dc
5
RECALL 1 OUT
RECALL : 5 V dc
6
STORE OUT
STORE :
0 V dc
7
RECALL 0 OUT
RECALL : 5 V dc
8
THREE OUT
THREE :
0 V dc
9
GND
GND for signal
10
REMOTE SYNC OUT
REMOTE SYNC : 5 V dc
11
BOTH OUT
BOTH :
0 V dc
12
CH-1-ON OUT
CH-1
ON : 0 V dc
13
CH-2-ON OUT
CH-2
14
CH-3-ON OUT
CH-3
15
A/B OUT
A : 5 V dc
B : 0 V dc
*4 : This is set using the S103-4 and -5 switches on the AT-141 board.
4 : ON : Recall system (5 : OFF 1125 SDI/ON 525/625 SDI)
4 : OFF : 1735HD/1730HD
TRUNK LINE (D-sub 9-pin, Female)
1
5
6
9
_ _ _ _ _ EXT VIEW _ _ _ _ _
No.
Signal
Specifications
*5
1
NC (DCD IN)
No connection
*5
2
EXT-CMD0-IN (RXD IN)
*5
3
EXT-CHD0-OUT (TXD OUT)
*5
4
(DTR-OUT)
12 V, 15 kZ
5
GND
*5
6
(DSR IN)
No connection
*5
7
EXT-CMD1-OUT (RTS OUT)
*5
8
EXT-CHD1-IN (CTS IN)
9
NC
No connection
*5 : This is set using the S1 switch on the AT-141 board.
AT :
(AUX)
DPR : Set using TRUNK.
1-5 (E)

Hide quick links:

Advertisement