1-5. Settings of Switches and Controls on Boards
. S41 (PROD RTS/CLEAR)
. S504 (INCOM PROD SELECT)
Set the intercom system of the producer line.
Factory setting : 4W (S504)
RTS (S41)
4-wire system
RTS system
Clear-Com system
. S101 (RET-SET)
Select the BNC connector that the RET VIDEO signal is
to be connected to when S110 on the AT-141 board is set
to LOC. The switches can be set for each RET channel.
Top slot
RET1
S101-1
OFF
S101-2
OFF
RET2
S101-3
OFF
S101-4
OFF
RET3
S101-5
OFF
S101-6
OFF
RET4
S101-7
OFF
S101-8
OFF
Factory setting : All OFF
n
The RET signal formats are already fixed.
. S102-1 to 7
Not used.
. S102-8 (NTSC/PAL)
When the RC-86 board is not mounted, set NTSC/PAL
of the REF input and character output. When the RC-86
board is mounted, perform the setting according to the
setting of S802 on the RC-86 board.
ON : PAL (for CE)
OFF : NTSC (for J/UC)
Factory setting : OFF
. S103-1 (HD-ANA-OUT-1 RGB/YCD)
This switch is valid only when the ADA-59 board
(HKCU-902) is mounted. Select the signal output from
the OUTPUT1 connector on the ADA-59 board of the
rear panel.
ON : Y/P
/P
B
R
OFF : RGB
Factory setting : OFF
1-12 (E)
S504
S41
4W
_
RTS
RTS
RTS
CLEAR
Second
Third
slot from
slot from
the top
the top
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
. S103-2 (HD-ANA-OUT-2 RGB/YCD)
This switch is valid only when the ADA-59 board (HKCU-
902) is mounted. Select the signal output from the OUT-
PUT2 connector on the ADA-59 board of the rear panel.
ON : Y/P
/P
B
R
OFF : RGB
Factory setting : OFF
. S103-3
Not used.
. S103-4 (RECALL TYPE CTL MODE SEL)
Set the type of the waveform monitor when S103-5 on
the AT-141 board is ON.
ON : 525/625/1125 SDI (Recall system)
OFF : Others SDI (Recall system) (Reserved)
Factory setting : OFF
. S103-5 (WFM CTL SIGNAL SEL)
Select the waveform monitor control signal output from
the WF REMOTE connector of the rear panel.
ON : Recall system control signal
(Depends on the setting of S103-5 on the AT-
141 board.)
OFF : Control signal dedicated to 1735HD/1730HD
Factory setting : OFF
. S103-6 (HD-ANA-OUT-2 LOCAL/REMOTE)
Set whether the signal that is output when the OUTPUT2
connector on the ADA-59 board (HKCU-902) is used for the
waveform monitor, is switched by pressing the ENC button
(MONITOR SELECT block) on the control panel of RCP.
ON : Selectable
ENC button lights off : RGB
ENC button lights : Y/P
OFF : Not selectable (Depends on the setting of S103-
2 on the AT-141 board.)
Factory setting : OFF
. S103-7
Not used.
. S103-8 (MONI CTL MODE SEL)
Select the method to switch the output of the PIX OUT
and WF OUT connectors on the DIF-102 board (HDCU-
900), the PIX OUT connector on the ADA-59 board
(HKCU-902), and the PIX OUT and WF OUT connec-
tors on the VDA-57 board (HKCU-901).
ON : Selectable using RCP only : DIF-102 board/
Selectable using MSU only : VDA-57 board
OFF : Selectable using both RCP and MSU (The last
press has priority.)
Factory setting : OFF
/P
B
R
ADA-59 board