1-5. Settings of Switches and Controls on Boards
1-5-2. DPR-163 Board
9
8
7
6
S812
S805
S807
S801
S802
S803
S813
S811
S809
S806
S808
S804
S810
MAIN OUTPUT
DPR
SYSTEM
POWER
POWER /1.001
60
50
P
S
F
CHU LOCK
30
25
24
DPR-163 board (A side/panel side)
n
Do not change the settings of the switches describes
"Factory use only".
. S701 (AUDIO PHASE)
This switch is used to match the amount of delay of MIC
and AES/EBU format audio signal with the video signal.
About 5 msec. is delayed per one step.
Example 7 : 1 FRAME DELAY (30 FRAME/SEC)
8 : 1 FRAME DELAY (25 FRAME/SEC)
Factory setting : 0
. S801 (EXT COM SEL)
Select the command trunk line mode.
1ch : Bi-directional communication line containing
one communication line capacity with doubled
band width of 2ch, having double spectrum
2ch : Bi-directional communication line containing
two communication line capacity (Can receive
signal equivalent to RS-232C (19.2 kbps).)
Factory setting : 2ch
1-16 (E)
5
4
3
2
1
S701
OPTICAL
AUDIO PHASE
CONDITION
540P
1035
CCU
CHU
. S802
Not used.
A
. S803 (COLOR BARS OUTPUT MODE SEL)
When you turn off the power of the camera or the
B
communication with the camera is cut, select the signal
to be output from the CCU.
C
ON : Color bar signal
OFF : Gray signal
D
Factory setting : OFF
E
. S804 (FORMAT SEL)
Select which of the HDCU-900 or MSU is used to set
F
the shooting operation format of the camera.
REMOTE : Set using MSU.
G
LOCAL : Set using the switch on the DPR-163
H

board.

Factory setting : REMOTE
J
. S805 (540P/NOT SEL)
K
When S804 on the DPR-163 board is set to LOCAL, set
the operation mode of the camera.
L
540P : 540P
NOT : Normal camera shooting operation
M
Factory setting : NOT
. S806 (PsF/INTERLACE SEL)
When S804 on the DPR-163 board is set to LOCAL set
the PsF/Interlace of the camera.
PsF : PsF system
Intr : Interlace system
Factory setting : Intr
. S807 (FIELD FREQ. SEL)
When S804 on the DPR-163 board is set to LOCAL, set
the operation field frequency of the camera.
48 : 48 Hz field
50 : 50 Hz field
60 : 60 Hz field
Factory setting : 60
. S808-1 to 8
Factory use only
Factory setting : All OFF
. S809-1 to 8
Factory use only
Factory setting : All OFF
HDCU-900 IMM