Sony HDCU-900 Series Installation And Maintenance Manual page 21

Hd camera control unit
Hide thumbs Also See for HDCU-900 Series:
Table of Contents

Advertisement

. S104-1 to 8
Factory use only
Factory setting : OFF
. S105-1 to 8
Factory use only
Factory setting : S105-5 only is ON
All others are OFF
. S106 (1-8 CCU No.)
This switch is mainly used to set the CCU numbers
while RCP is connected to the HDCU-900.
Use switches 1 to 8 to set the CCU numbers from 1 to 96
in BCD notation.
Use switches 1 to 4 to set the first digit and use switches
5 to 8 to set the second digit. ("a" to "f" are invalid.)
Factory setting : OFF
OFF
ON
1
First
2
0
3
digit
4
5
Second
6
5
7
digit
8
CCU No.
50
61
. S107 to S109
Not used.
. S110 (RETURN REMOTE/LOCAL)
Set which of HDCU-900 or MSU is used to set the
signal format to be connected to the RET VIDEO
connector on the rear panel.
REM : Set using MSU.
LOC : Set using the switch on the AT-141 board.
Factory setting : REM
. S111 (MARKER REMOTE/LOCAL)
Select the HDCU-900 or MSU to control the aspect
marker and skin gate signal that will be output from the
monitor.
REM : Set using MSU.
LOC : Set using the switch on the AT-141 board.
Factory setting : REM
. S112 (MAKER MIX SIGNAL SEL)
When S111 on the AT-141 board is set to LOC, set
whether the ASPECT MAKER signal is inserted into the
HD-SDI MONITOR output signal.
ON : Inserted
OFF : Not inserted
Factory setting : OFF
HDCU-900 IMM
1
3
2
8
6
7
72
83
94
. S113 to S115
Not used.
. S120 (CONVERSION DELAY)
Select delay amount between the HD-SDI signal that is
output from the first stage and the signal after formatting
the HD-SDI signal.
90H : Minimum delay mode for 90H lines of the HD
signal
1Frm : Same phase mode that delayed at one frame
Factory setting : 90H
. S121 (MODULAT)
Select whether the aspect modulation signal is inserted
into the HD-SDI MONITOR output signal when S111
on the AT-141 board is set to LOC.
ON : Inserted
OFF : Not inserted
Factory setting : OFF
. S122 (10F-BB)
4
Set this switch when the multi frame lock is desired
using the BB signal (SMPTE318M) supporting 10-field
9
sequence as a reference signal.
ON : Set the 10F-BB signal as master reference.
OFF : When the 10F-BB signal is not input to REFER-
ENCE.
Factory setting : OFF
. S123 (MOD-LEVEL)
When the S111 on the AT-141 board is set to LOC,
adjust the aspect modulation level.
Factory setting : 8
. S124 (ZEBRA LEVEL)
When S111 on the AT-141 board is set to LOC, adjust
the zebra level of the skin gate of the monitor output.
Factory setting : 8
. S125 (MARKER SET)
Set the type of the aspect marker.
Switch setting
0
1
2
3
4
5
6
7
8 through F
Factory setting: 8
1-5. Settings of Switches and Controls on Boards
Aspect marker
4 : 3
13 : 9
14 : 9
15 : 9
None
16 : 8.649
16 : 6.75
None
Interlocking down-converter
1-13 (E)