8. Information for the specialist electrician

H
Caution: Important installation instructions.
Please follow all installation instructions
since incorrect installation can lead to
the destruction of the motor and the
switching unit.
e1-e4: the setting of the end stops requires a Geiger
setting switch
e5: the setting can be realized with any switch allowing
simultaneous UP and DOWN controls.
e1-e4: a non-locking switch (series switch) is needed in
order to reach the shade position.
See point 10 "Operation".
e5: a locking switch is here necessary (no simultaneous
UP and DOWN commands)
The operations with the service clamps may be accom-
plished only by an electrical specialist.
Motors with electronic limit stops can be connected in
parallel. In this case the maximum load of the switching
unit must not be exceeded.
When changing the running direction the switchover must
be effected through an off-position.
When changing the running direction the switchover time
must be at least 0.5 s.
With a three-phase network, please use the same external
conductor in order to control the UP and DOWN directions.
Connecting cables with plug connectors of the Hirschmann
Company are tested and approved with couplings of the
Hirschmann Company.
In order to prevent a malfunction caused by coupling, the supply line (ref. NYM) from the
actuator/switch to the motor must not exceed 100m in case of motors with electronic end stops.

9. Control features

EN
Electronic motor controls features
Indirect shade position
The blind always moves to the lower end position first,
turns round there and moves to the shade position.
Direct shade position
The blind moves directly to the shade position
Preset shade position
0,5 rotations over the lower end position
Antifreeze protection
2 rotations from the lower end position
Torque shut-down in UP direction
Set up in learning mode
Only the upper end position has to be learned
A Geiger setting switch is required
External setting switch
A switch which allows simultaneous UP and DOWN
commands is necessary
6
EN
Mains: 230V / 50Hz
L1
N
PE
PE
e1
e2
n
n
n
n
n
n
Gerhard Geiger GmbH & Co. KG | 100W1503
N
1
2
3
Electronic /
mechanical
limit stop
e3
e4
e5
n
n
n
n
n
n
n
n
n
n
n
en
V001