Venetian blind motor: GEIGER GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage et d’utilisation Instrucciones originales de instalación y funcionamiento...
1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
The height of installation must be at least 1.5 m above the floor. f Permanently installed control devices must be attached visibly. f In case of devices extending horizontally, a horizontal distance of at least 0.4 m must be respected between the fully extended part and any other fixed element. www.geiger.de...
A plug for the disconnection of the motor from the power supply must be accessible after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type. f The device must be mounted as described in the installation instructions. Fixations shall not be made with adhesives since they are regarded as unreliable.
7. Installation instructions Prior to installation please check to ensure there is no visible damage to the motor like cracks or open cables. Before fixing please check the strength of the masonry and of the surface. Head rail opening at top: www.geiger.de...
Page 6
Head rail opening at bottom: Gerhard Geiger GmbH & Co. KG | 100W2529 V001 0823...
If you press the DOWN adjustment button for the lower end position and DOWN direction, the Venetian blind can move over the lower turning position and move up again. If the Venetian blind hits the limit stop switch now, the GJ56 is not switched off and the Venetian blind could be damaged. www.geiger.de...
Restore free motion of the limit stop switch. Re-adjust the end positions 11. Maintenance The drive is maintenance-free. Gerhard Geiger GmbH & Co. KG | 100W2529 V001 0823...
309 mm Diameter 55 mm Weight ca. 1,70 kg Air humidity dry and non-condensing place Storage temperature T = -15°C .. +70°C Subject to technical modifications. Please find information to the ambient temperature range of our GEIGER motors under www.geiger.de www.geiger.de...
In the interest of environmental protection, please contact your local government’s recycling or solid waste management department to learn more about the services it provides. Waste disposal of electric and electronic equipment Electrical and electronic equipment must be collected and disposed of separately in accordance with EU regulations. www.geiger.de...
Page 12
They will be happy to assist you. Gerhard Geiger GmbH & Co. KG Schleifmühle 6 | D-74321 Bietigheim-Bissingen T +49 (0) 7142 9380 | F +49 (0) 7142 938 230 info@geiger.de | www.geiger.de Gerhard Geiger GmbH & Co. KG | 100W2529 V001 0823...