Removal of the keyboard FCUxxxx-Design
8.1

Installing the temperature sensor

Place of
Installation
Fig.5: Place of installation for steam bath sensor
8.1.1

Temperature sensor

The following temperature sensor variants are available:
20 Installation instructions Steam bath control Series FCU2000/FCU3000/FCU4000/FCU5000 M_FCUxxxx-Steam_EN / Version V2.04
Note!
The sensor of the thermostat must be installed in such a way that it is
not affected by the incoming air.
Note!
The temperature values displayed on additional thermometers in the
cabin can deviate from the displayed values on the control. This could
be due to the following reasons:
Depending on the cabin, the temperature differences from the floor to
the ceiling can be up to 30 K.
Instruments with indicator needles react slower than electrical
measuring and display systems used for the control.
ATTENTION: The assembler of the device has to consider the specific conditions of
the cabin such as the position of the steam exit, the in- and out-coming air, the
door(s), the shape of the ceiling etc. Then the sensor can be installed at an
adequate place!