Installation

5.1

ESD protection

5.2

Installation of steam bath control device FCUxxxx-Steam

Installation
The steam bath control device should be installed at a distance of at least 5 cm from the
walls or other equipment. There should be a distance of 10 cm between two steam bath
control devices.
The control unit must be mounted so that it is at any time accessible! (e.g. for service,
wear parts, fuses, etc.)
5.3
Installation of the operating control of FCUxxxx-Steam-Design und
FCUxxxx-Steam-Design-Glas
Installation
The operating control can be installed maximum 100 m away from the basic control
device.
Installation instructions Steam bath control Series FCU2000/FCU3000/FCU4000/FCU5000 M_FCUxxxx-Steam_EN / Version V2.04 15
ATTENTION!
Note ESD protection!
Do not touch on electrical parts because of ESD protection reasons.
When assembling only touch the circuit board at the plastic case or at
the edge of the board.
Also only touch the connection cable to the circuit board, on the
connector. Thereby do not touch the contact surfaces.
Therefore:
– Take appropriate protections. Touch a grounded piece of metal as a
minimum protection.
Note!
At FCUxxxx-Design-Glas the main switch of the control unit must be
accessible.
ATTENTION!
Damage or malfunction of the operating control FCUxxxx-Steam-
Design-Glas by steam, humidity or water!
Therefore:
– Must be ensured, that either steam, humiditiy or water can occur at or
in the keyboard.
Installation