Bartscher 5FL EBO-1 Instruction Manual page 21

Table of Contents

Advertisement

When adapting from liquid gas to natural gas, for proper regulation turn the screw
(at the top left, as in the diagram) counter-clockwise with a small screwdriver until the
desired flame strength is reached.
When adapting from natural gas to liquid gas, for proper regulation turn the screw
(at the top left, as in the diagram) clockwise with a small screwdriver until the desired
flame strength is reached .
Next, replace the regulation dial and quickly turn it from the highest flame position to
the lowest flame position, then check to see that the flame is sufficient to maintain
heating of the thermal element. If not, adjust the low flame setting.
After changing jets or after recalibration, always ensure the flame has a blueish
color, burns regularly, does not separate from the burner, and does not disappear
when adjusting from high flame to low flame.
CAUTION!
The device functions properly only when the pressure in the gas installation is
within the values given in the table labeled "Gas categories in selected
countries" on pp. 43-44.
CAUTION!
Properly reassemble all parts after making alterations or recalibrating the
device to ensure it is prepared for further use.
Inspect gas installation seals using a soap solution, never by using an open
flame.
After adaptation, remove the old sticker with regulation values and replace it
with a new one appropriate for the new gas type.
- 50 -

Advertisement

Table of Contents
loading

Table of Contents