Dimensions; Figure A-1 Gt100 Dimensions; Table A-8 Auxiliary Control Interface Screw Size And Torque Values - Xantrex GT100 Series Planning And Installation Manual

Grid-tied photovoltaic inverter
Table of Contents

Advertisement

Specifications

Dimensions

1861.8 mm
(73.3 in)

Figure A-1 GT100 Dimensions

A–6
Table A-8 provides acceptable screw sizes, and torque values to be connected to
the GT100 Auxiliary Control Interface terminal connections.

Table A-8 Auxiliary Control Interface Screw Size and Torque Values

Max. # of
Aux Control
Conductors
Connections
per Terminal
TB7-1,2
1
Remote
Emergency
Stop
TB7-3,4
1
Aux Enable/
Disable
1702.0 mm
(67.0 in)
This manual for use by qualified installers only
Screw
(Hardware)
Torque
Size
Requirements
6-32 × 0.5, Pan
1.35 Nm
Hd Phil
(12 lb in)
(provided)
6-32 × 0.5, Pan
1.35 Nm
Hd Phil
(12 lb in)
(provided)
1171.0 mm
(46.1 in)
Signal Type
N.C. Contact
@15Vdc,
10mA
N.C. Contact
@15Vdc,
10mA
153379

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt100-480-ngGt100-480-pgGt100-208-pgGt100-208-ng

Table of Contents