Table 24: Carrier frequency and derating at normal duty (ND) rating - three-phase 400 V class
Model
Normal
CIPR-
Duty
GA50A
(ND)

Rating
CIMR-
(kW)
VA4A

4001
0.1
0001
4002
0.2
0002
4004
0.6
0004
4005
0.8
0005
4007
1.1
0007
4009
1.5
0009
4012
2.2
0011
4018
3.0
0018
4023
3.7
0023
4031
5.5
0031
4038
7.5
0038
4044
11.0
4060
15.0
Carrier Frequency and Derating (A)
C6-02=1
C6-02=2
(2.0kHz)
(5.0kHz)
1.2
1.2
1.2
1.2
2.1
2.1
2.1
2.0
4.1
4.0
4.1
3.8
5.4
5.4
5.4
5.1
7.1
6.5
6.9
6.2
8.9
8.6
8.8
8.0
11.9
10.8
11.1
10.2
17.5
17.0
17.5
16.2
23.4
21.3
23.0
20.5
31.0
28.2
31.0
27.5
38.0
36.3
38.0
34.5
44.0
44.0
60.0
54.5
C6-02=3
C6-02=4
(8.0kHz)
(10.0kHz)
1.2
1.1
1.2
1.1
1.8
1.6
1.8
1.6
3.4
3.0
3.4
3.0
4.8
4.2
4.8
4.3
5.5
4.9
5.5
4.9
7.3
6.5
7.2
6.4
9.2
8.2
9.2
8.1
14.5
12.8
14.8
13.1
18.2
16.1
18.0
15.9
24.1
21.3
24.0
21.3
31.0
27.5
31.0
27.5
39.0
34.5
46.3
40.8
VAN-V19001E [V1000→GA500]
C6-02=5
C6-02=6
(12.5kHz)
(15.0kHz)
0.9
0.7
0.9
0.7
1.3
1.1
1.4
1.1
2.5
2.0
2.5
2.0
3.6
2.9
3.6
2.9
4.1
3.3
4.1
3.3
5.4
4.4
5.3
4.3
6.8
5.5
6.8
5.5
10.8
8.7
11.0
8.9
13.4
10.8
13.4
10.8
17.9
14.4
17.8
14.4
23.0
18.6
23.0
18.6
29.0
23.4
33.9
27.0