Models To Be Replaced - YASKAWA V1000 Replacing Manual

Procedure for replacing the v1000 with the ga500
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

1. Models to Be Replaced

Old model
V1000
Type: CIMR-VAA
New model
GA500
Catalog code: GA50A
Replacement Capacity
The following table shows the matching between the old model (V1000) and replacement model type (GA500) numbers.
Differences in specification between the V1000 and the GA500 are highlighted in bold.
Table 1: 200 V Class (three-phase)
V1000
Model
CIMR-VA2A0001
CIMR-VA2A0002
CIMR-VA2A0004
CIMR-VA2A0006
CIMR-VA2A0008
CIMR-VA2A0010
CIMR-VA2A0012
CIMR-VA2A0018
CIMR-VA2A0020
CIMR-VA2A0030
CIMR-VA2A0040
CIMR-VA2A0056
CIMR-VA2A0069
Table 2: 200 V Class (single-phase)
V1000
Model
CIMR-VABA0001
CIMR-VABA0002
CIMR-VABA0004
CIMR-VABA0006
CIMR-VABA0010
CIMR-VABA0012
CIMR-VABA0018
200 V Class (for three-phase power supply): 0.1 kW to 15 kW
(for single-phase power supply): 0.1 kW to 3.7 kW Heavy Duty Rating (HD)
400 V Class (for three-phase power supply): 0.2 kW to 15 kW
(for three-phase power supply): 0.4 kW to 18.5 kW Normal Duty Rating (ND)
Rated Output
Rated Output
Current
Current
Normal Duty
Heavy Duty
(ND) Rating
(HD) Rating
1.2 A
0.8 A
1.9 A
1.6 A
3.5 A
3.0 A
6.0 A
5.0 A
8.0 A
6.9 A
9.6 A
8.0 A
12.0 A
11.0 A
17.5 A
14.0 A
21.0 A
17.6 A
30.0 A
25.0 A
40.0 A
33.0 A
56.0 A
47.0 A
69.0 A
60.0 A
Rated Output
Rated Output
Current
Current
Normal Duty
Heavy Duty
(ND) Rating
(HD) Rating
1.2 A
0.8 A
1.9 A
1.6 A
3.3 A
3.0 A
6.0 A
5.0 A
9.6 A
8.0 A
12.0 A
11.0 A
-
17.5 A
0.2 kW to 18.5 kW Normal Duty Rating (ND)
0.2 kW to 5.5 kW Normal Duty Rating (ND)
Rated Output
GA500
Current
Catalog code
Normal Duty
(ND) Rating
GA50A2001
1.2 A
GA50A2002
1.9 A
GA50A2004
3.5 A
GA50A2006
6.0 A
GA50A2008
8.0 A
GA50A2010
9.6 A
GA50A2012
12.2 A
GA50A2018
17.5 A
GA50A2021
21.0 A
GA50A2030
30.0 A
GA50A2042
42.0 A
GA50A2056
56.0 A
GA50A2070
70.0 A
GA50A2082
82.0 A
Rated Output
GA500
Current
Catalog code
Normal Duty
(ND) Rating
GA50AB001
1.2 A
GA50AB002
1.9 A
GA50AB004
3.5 A
GA50AB006
6.0 A
GA50AB010
9.6 A
GA50AB012
12.2 A
GA50AB018
--
VAN-V19001E [V1000→GA500]
Heavy Duty Rating (HD)
Heavy Duty Rating (HD)
Rated Output
Current
Heavy Duty
(HD) Rating
0.8 A
1.6 A
3.0 A
5.0 A
6.9 A
8.0 A
11.0 A
14.0 A
17.6 A
25.0 A
33.0 A
47.0 A
60.0 A
75.0 A
Rated Output
Current
Heavy Duty
(HD) Rating
0.8 A
1.6 A
3.0 A
5.0 A
8.0 A
11.0 A
17.6 A