Cleaning Instructions; Dispenser; Daily; Cleaning Exterior Surfaces - Cornelius IDC 255 PROGATE DRIVE THRU Operator's Manual

Hide thumbs Also See for IDC 255 PROGATE DRIVE THRU:
Table of Contents

Advertisement

D
ISPENSER

Daily

WARNING: Disconnect Power Before Cleaning. Do not use metal scrapers, sharp objects or
abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result. Do not
use solvents or other cleaning agents, as they may attack the plastic material.
Soap solution – Use a mixture of mild detergent and warm (100
Sanitizing solution – Dissolve 2 packets (4 oz.) Stera Sheen Green Label into 2 gallons of warm (80-
o
100
F) water to ensure 200 ppm of available chlorine.

Cleaning Exterior Surfaces

Important: Perform the following daily.
1.
Remove cup rest from drip tray.
2.
Wash the drip tray with soap solution. Rinse drip tray with clean water and allow solution to run
down the drain.
3.
Wash cup rest with soap solution and rinse in clean water. Install the cup rest in the drip tray.
4.
Clean all exterior surfaces of Unit with soap solution, then rinse with clean water.

Lid Dispenser Maintenance

The lid dispensers are manufactured out of materials that can survive chlorine-based cleaners and warm
water <100°F. Ensure that the parts are thoroughly dried before refilling with lids.
NOTE: Lid dispenser parts should not be soaked in the powersoak washing machine as this will
result in the parts getting scratched. Instead the dispenser parts should be rinsed in warm soapy
water when dry.

Ice Chute Maintenance

The Ice chute needs to be cleaned daily to remove buildups.
NOTE: The ice chute has an built in safety feature meaning that when the ice chute cover is
removed the unit is disabled. If the ice chute cover is not properly installed the agitator and ice
chute gate will not function.
Removing and Reinstalling the Ice Chute
1.
Grab ice chute and slide up until it comes
to a stop.
2.
Pull forward.
3.
Properly clean the ice chute. The ice chute
is manufactured out of materials that can
survive chlorine-based cleaners and warm
water <100°F.
IMPORTANT: Do not put the ice chute into a
dishwasher.
4.
Replace when finished.
5.
If agitator or ice chute does not operate
remove and reinstall chute cover.
© 2006, IMI Cornelius Inc.

CLEANING INSTRUCTIONS

- 7 -
IDC 255 Progate Drive Operator's Manual
o
F) potable water.
FIGURE 11
Publication Number: 621057419OPR

Advertisement

Table of Contents
loading