Sirona TENEO Operating Instructions Manual
Hide thumbs Also See for TENEO:
Table of Contents

Advertisement

qbkbl
léÉê~íáåÖ=fåëíêìÅíáçåë=
båÖäáëÜ

Advertisement

Table of Contents
loading

Summary of Contents for Sirona TENEO

  • Page 1 qbkbl léÉê~íáåÖ=fåëíêìÅíáçåë= båÖäáëÜ...
  • Page 3: Table Of Contents

    Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO Table of contents General information ................... Dear Customer, ................Contact data ..................Notes on these Operating Instructions ..........Other valid documents ..............Warranty and liability ................ Intended use ..................Formats and symbols used ..............
  • Page 4 Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO Dentist element ................3.6.1 Instrument positions ............. 3.6.2 EasyTouch user interface ............ 3.6.3 Touchscreen ................ 3.6.4 Fixed keys on the dentist element........Assistant element ................3.7.1 Instrument positions ............. 3.7.2 User interface...............
  • Page 5 Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO Dentist element ................4.5.1 Maximum load capacity............4.5.2 Height adjustment ..............4.5.3 Motor-driven travel track............4.5.4 Fixed keys on the dentist element........4.5.5 Quick setting keys and function levels .........
  • Page 6 Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO 4.12 External PC ..................4.12.1 SIVISION program ............... 4.12.2 Open USB port..............4.13 Configuration of the treatment center (setup) ........4.13.1 Opening the setup programs..........4.13.2 Configuring the EasyTouch user interface ......
  • Page 7 Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO Components of the water unit ............5.5.1 Clean the gold trap ............... 5.5.2 Clean and disinfect the cuspidor bowl........5.5.3 Adding disinfectant for water ..........5.5.4 Change the water and air filters ...........
  • Page 8 Sirona Dental Systems GmbH Table of contents Operating Instructions TENEO 11.5 Other dialogs ..................11.5.1 Timer screen ................ 11.5.2 SPRAYVIT program ............. 11.5.3 Tumbler filling settings screen..........11.5.4 Flushing settings screen ............11.6 SIVISION program ................11.6.1 SIDEXIS ................11.6.2 PowerPoint................
  • Page 9: General Information

    General information Dear Customer, ® We are pleased that you have equipped your practice with the TENEO treatment center. Our claim is to recognize our customers' demands in good time and to create innovative solutions. Together with your trade partner, you have configured the unit to suit your individual taste.
  • Page 10: Other Valid Documents

    Exclusion of liability In the event that the system owner fails to fulfill its obligation to perform maintenance activities or ignores error messages, Sirona Dental Systems GmbH and its authorized dealers cannot assume any liability for any damage thus incurred.
  • Page 11: Intended Use

    1 General information Sirona Dental Systems GmbH Intended use Operating Instructions TENEO Intended use This dental treatment center is intended for the diagnosis, therapy and dental treatment of humans by properly trained and qualified personnel. This unit is not intended for operation in areas subject to explosion hazards.
  • Page 12: Safety Information

    2 Safety information Sirona Dental Systems GmbH Identification of danger levels Operating Instructions TENEO Safety information Identification of danger levels Lead text To prevent personal injury and material damage, please observe the warning and safety information provided in the present operating instructions. Such...
  • Page 13: Maintenance And Repair

    No restrictions apply when using salt blasting devices in connection with Sirona treatment centers. However, in such cases, make sure that the system is subsequently flushed with an adequate amount of water. 61 93 556 D3509...
  • Page 14: Patient Chair

    Unsuitable care and cleaning agents may corrode the surface of the unit. Therefore, use only care and cleaning agents which have been approved by Sirona. For more information, please refer to "Care and cleaning agents" [ 135]. 61 93 556 D3509...
  • Page 15: Modifications And Extensions Of The System

    Sirona accessories or third-party accessories expressly approved by Sirona. The user assumes the risk of using non-approved accessories. If any devices not approved by Sirona are connected, they must comply with the applicable standards, e.g.: IEC 60950 for information technology equipment (e.g. PC) and IEC 60601-1 for medical electrical equipment.
  • Page 16: Dismantling/Installation

    2 Safety information Sirona Dental Systems GmbH Dismantling/Installation Operating Instructions TENEO 2.16 Dismantling/Installation Observe the installation instructions When dismantling and reassembling the system, proceed according to the installation instructions for new installation in order to guarantee its functioning and stability.
  • Page 17: System Description

    EN 301489-1, EN 301489-17, EN 300328 The modules meet the requirements of the Federal Communications Commission (Part 15 of the FCC Rules). FCC ID: SIFNANOLOCAVR0108 ® TENEO is a registered trademark of Sirona Dental Systems GmbH. 61 93 556 D3509 D3509.201.01.02.02 19.09.2008...
  • Page 18: System Overview

    3 System description Sirona Dental Systems GmbH System overview Operating Instructions TENEO System overview The treatment center comprises the following main components: Patient chair [ 19] Motor-driven headrest [ 19] (shown here) or MultiMotion headrest [2 20] Foot control [ 21] (with cable or wireless link)
  • Page 19: Patient Chair

    3 System description Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Patient chair The patient chair features a variety of motor adjustment options to optimally adapt the patient's position to the given treatment. Motor-driven headrest (shown here) or MultiMotion headrest...
  • Page 20: Multimotion Headrest

    3 System description Sirona Dental Systems GmbH Headrest Operating Instructions TENEO Manual tilting via quick mechanical adjustment Shifting/rotation of the head support via the magnetic holder Removable head pad with magnetic holder Quick mechanical adjustment of headrest tilt Upper 4-way switch for headrest functions Lower 4-way switch for chair functions For details, see "Adjusting the motor-driven headrest"...
  • Page 21: Foot Control

    3 System description Sirona Dental Systems GmbH Foot control Operating Instructions TENEO Removable head pad Operating handle for tilt adjustment Release button (concealed) for rotation and lateral tilt Headrest extension for stature adjustment Release button for removing the headrest For details, see "Adjusting the MultiMotion headrest" [ 47].
  • Page 22: Dentist Element

    3 System description Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Foot pedal as speed foot control or direct starter Left button (program key S or spray) 4-way foot switch plate for cursor control Right button (program key 0 or chip blower)
  • Page 23: Instrument Positions

    3 System description Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Removable instrument holder (max. 6 instruments) Removable handles (left/right) Touchscreen for display and operation Fixed keys Main switch X-ray viewer Skid-proof silicone mat Additional holder for intraoral camera...
  • Page 24: Touchscreen

    3 System description Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Touchscreen (pressure-sensitive user interface) Fixed keys (membrane keyboard) 3.6.3 Touchscreen The touchscreen displays virtual function keys according to the program selected. A list of all function keys is provided in the Appendix of this document, see "Overview of all function keys"...
  • Page 25: Fixed Keys On The Dentist Element

    3 System description Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO SIVISION program 3.6.4 Fixed keys on the dentist element NOTE: Detailed description For a more detailed description of the fixed key functions, see "Fixed keys on the dentist element" [ 57].
  • Page 26 3 System description Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO When the Tumbler filling key is pressed (> 2 s), the filling time and water heating settings screen appears. Flushing Starts the flushing of the cuspidor bowl. When the Flushing key is pressed (> 2 s), the Flushing Time settings screen appears.
  • Page 27: Assistant Element

    3 System description Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO Assistant element The functional scope of the assistant element is adapted to the dental assistant's field of activity. It can, however, also be positioned so as to enable unassisted treatment by the dentist.
  • Page 28: Instrument Positions

    3 System description Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO 3.7.1 Instrument positions The following instrument position assignments are possible: Holder 1 Holder 2 Holder 3 Holder 4 SPRAYVIT L multifunctional Spray aspirator Saliva ejector Mini L.E.D. curing light...
  • Page 29: Water Unit

    3 System description Sirona Dental Systems GmbH Water unit Operating Instructions TENEO Chair program 0 Entry/exit position (freely programmable) Chair programs 1 and 2 (freely programmable) Headrest Moves the motor-driven headrest out/in for size adjustment. These keys do not function if a MultiMotion headrest is installed.
  • Page 30: External Device Connection

    3 System description Sirona Dental Systems GmbH External device connection Operating Instructions TENEO Swiveling cuspidor bowl Tumbler filler (depicted) or tumbler filler with automatic sensor control for automatic filling of the tumbler Maintenance cover for disinfectant Mount for support arm of operating light...
  • Page 31: Sirona Dental Systems Gmbh

    3 System description Sirona Dental Systems GmbH External device connection Operating Instructions TENEO A I R T E R x . 6 H 2 5 . 3 A e T 6 F u s Inlet connector with power supply (max. 6 A) Fuse for inlet connector (6.3 A slow-blow)
  • Page 32: Operation

    4 Operation Sirona Dental Systems GmbH Starting up the treatment center Operating Instructions TENEO Operation Starting up the treatment center 4.1.1 Initial startup Sanitation must be performed prior to initial startup of your treatment center. This is done by filling all water-bearing lines with a concentrated disinfectant to reduce the exposure of the water to bacteria.
  • Page 33: Selecting A User Profile

    4 Operation Sirona Dental Systems GmbH Starting up the treatment center Operating Instructions TENEO The power switch is turned on. Press the main switch on the dentist element. The LED of the main switch lights up on the dentist element.
  • Page 34: Control Concept Of Touchscreen

    4 Operation Sirona Dental Systems GmbH Control concept of touchscreen Operating Instructions TENEO The Start program is displayed on the touchscreen in the Simple (shown here) orAdvanced Start program mode, see "Simple/Advanced Start program operating mode" [ 44]. Select the desired user profile. Touch the User profile key as often as necessary.
  • Page 35: Foot Control

    4 Operation Sirona Dental Systems GmbH Foot control Operating Instructions TENEO Status messages are displayed to indicate e.g. failure to communicate with the external PC, the need to change the amalgam separator or add disinfectant, the need to charge the battery of the wireless foot control, error messages, or the number of days left until the next maintenance call or sanitation run.
  • Page 36: Operating The Foot Control

    4 Operation Sirona Dental Systems GmbH Foot control Operating Instructions TENEO 4.3.1.1 Setting the wireless foot control on the treatment center The wireless foot control must be assigned to the treatment center via a registration. This prevents malfunctions caused by neighboring wireless foot controls.
  • Page 37: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Foot control Operating Instructions TENEO 4-way foot switch plate If the cursor control is switched on, it is operated via the 4-way foot switch plate, see "Using the cursor control" [ 38]. If the cursor control is switched off, then: All instruments are in place.
  • Page 38: Using The Cursor Control

    4 Operation Sirona Dental Systems GmbH Foot control Operating Instructions TENEO 4.3.3 Using the cursor control 4.3.3.1 Functionality Cursor control as an alternative mode of operation The touchscreen and the fixed keys of the dentist element can also be operated hand-free via the foot control. This method of operation optimally supports hygiene, especially in connection with sterile treatment work.
  • Page 39: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Foot control Operating Instructions TENEO Cursor path The cursor path runs between the pairs of keys, moving from top to bottom and from left to right, usually in multiple loops. The cursor path can be traversed between the starting and end points either in a forward or a reverse direction.
  • Page 40: Patient Chair

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Actuating a function or fixed key Press left button: Slide the 4-way foot switch plate to the left. Press the right button: Slide the 4-way foot switch plate to the right.
  • Page 41: Safety Stop

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Maximum load capacity of patient chair WARNING: The maximum load capacity of the patient chair is 165 kg acc. to ISO 6875 (tested with multiple safety acc. to IEC 60601-1).
  • Page 42: Triggering An Immediate Movement Stop

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Armrest, right Manual switching strip front/rear, right/left Toeboard Rear housing, rear lift frame, front lift frame right/left in each case. The three safety switches are jointly displayed on the touchscreen.
  • Page 43: Armrests

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Actuate the 4-way foot switch in any direction. Actuate the 4-way switch on the motor-driven headrest in any direction. All movements of the treatment center are stopped immediately. 4.4.4 Armrests The patient chair can be equipped with armrests on both sides.
  • Page 44: Simple/Advanced Start Program Operating Mode

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO If the armrest is removed, the supplied cover must be inserted in the mount on the patient chair instead of the armrest in order to bridge the safety switch.
  • Page 45: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Manual Chair Adjustment screen (for Simple Start program mode only) In the Advanced Start program mode, all function keys associated with movement of the patient chair are displayed together in a single screen.
  • Page 46: Adjusting The Motor-Driven Headrest

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO The Start program is displayed in the selected operating mode. 4.4.6 Adjusting the motor-driven headrest The motor-driven headrest can be adjusted via the touchscreen or directly on the headrest.
  • Page 47: Adjusting The Multimotion Headrest

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Via the 4-way switch Slide the upper 4-way switch to the left or right. Via quick mechanical adjustment Hold the headrest securely in place before unlocking it. Press buttons A together.
  • Page 48: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Raise the headrest slightly by raising the operating handle. The headrest is unloaded. Press the release on the operating handle. The lock for vertical adjustment is released. Press and hold the release. Holding the headrest by the operating handle, raise or lower it to the required position.
  • Page 49: Moving The Patient Chair Via Chair Programs

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Head pad magnet WARNING: The head pad contains a strong magnet on its bottom side. This magnet could affect any cardiac pacemaker located nearby. Furthermore, direct contact of the head pad with magnetic cards can delete data stored on the cards.
  • Page 50: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Cuspidor bowl moves to starting position NOTE: The cuspidor bowl automatically swivels back to its starting position The cuspidor bowl automatically returns beforehand to ensure that the patient does not collide with it during chair movements. This return travel is dependent on the chair movement and is executed only if a collision hazard exists.
  • Page 51: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO This can be used to set the cuspidor bowl so that it automatically moves inward when the mouth rinsing position (S) chair program is selected; see"Linking the movement of the cuspidor bowl to the mouth rinsing position"...
  • Page 52: Moving The Chair Manually

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Via the assistant element Press key 1 key or 2 on the assistant element briefly (< 2 s). NOTE: Chair programs 3 and 4 cannot be selected on the assistant element.
  • Page 53: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO Via the 4-way foot switch Slide the 4-way foot switch to the left or right. Via the 4-way switch Slide the upper 4-way switch to the left or right.
  • Page 54: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO 4.4.9.5 Moving the patient chair with the fine adjustment Depending on the type of treatment, it may be necessary to adjust the patient chair more slowly and more precisely (e.g., for tiny corrections in case of treatment under a microscope).
  • Page 55: Creating Chair And Shock Positioning Programs

    4 Operation Sirona Dental Systems GmbH Patient chair Operating Instructions TENEO 4.4.10 Creating chair and shock positioning programs Chair programs The six factory set chair programs: Mouth rinsing position S Entry/exit position 0 1 and 2 3 and 4 if selected can be individually reprogrammed for each of the six user profiles (A to F).
  • Page 56: Dentist Element

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Opening the chair sub-screen Opening the sub-screen The Start program is displayed on the touchscreen. Touch the Sub-screen key. The Start sub-screen is displayed. Switching the massage function on/off Touch the Massage Function key.
  • Page 57: Fixed Keys On The Dentist Element

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Entry/exit position WARNING: The patient's feet may get caught in the instrument hoses of the dentist element when he enters or leaves the patient chair. The patient may trip or fall.
  • Page 58: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.4.2 Timer function A set time can be counted down to zero with the timer function. Up to six timers can be preset. A time loop (automatic restart of the countdown) and an acoustic signal (when the set time has expired) can be added to each timer.
  • Page 59: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Optionally: You can switch the time loop and/or acoustic signal on/off while the timer is counting down. Touch the Time Loop and/or the Acoustic Signal key. If a function is switched on, the corresponding key is highlighted orange.
  • Page 60: Sirona Dental Systems Gmbh

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO This function is required to prevent premature curing of composite fillings. Composite function Press the Composite Function fixed key. If the composite function is switched on, the LED of the fixed key lights up on the dentist and assistant elements.
  • Page 61: D3509

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Setting the water tempering Switch the tumbler tempering function on/off. Touch the Water Tempering key. If the key is highlighted orange, the tumbler tempering function is activated. The water tempering keys are displayed.
  • Page 62: Quick Setting Keys And Function Levels

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.4.9 Clean Pressing this key deactivates the complete user interface of the dentist element. Pressing it again > 3 s reactivates the control panel. This is used to make sure that no unwanted functions can be accidentally triggered while cleaning the surface, see "Disinfecting the EasyTouch"...
  • Page 63: Saving Instrument Settings

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Motor screen with function levels Using quick setting keys or function You can select operation via quick setting keys or via function levels in the levels Setup program; see "Preselecting quick setting keys with SaveMode/with DropMode or function levels"...
  • Page 64: Placing The Instruments In Their Holders

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Press and hold key E1 or E2 (> 2 s). An audible signal sounds. The settings in the Instrument program and its sub-screen are saved to the corresponding function level.
  • Page 65 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.8.2 Selecting a coolant Air, spray or NaCl can be preselected as the instrument coolant in the sub- screen. The preselected coolant can then be switched on or off in the Instrument program.
  • Page 66 4.5.8.5 Preselecting the instrument light operating voltage The original Sirona halogen lamp is usually operated at 3.6 V. Voltages over 3.8 V destroy the lamp. The operating voltage can be adjusted for lamps made by other manufacturers.
  • Page 67 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Speed foot control Used to continuously adjust the instrument up to maximally the set speed and intensity values depending on the setting the foot control pedal. The Sub-screen of the removed instrument is displayed on the touchscreen.
  • Page 68 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO The peristaltic pump drive and a retaining bracket are attached to the dentist element. Please contact your local distributor if necessary. A new peristaltic pump hose is available. Attach the NaCl bottle to the retaining bracket of the dentist element.
  • Page 69: Electric Motor

    Flow rate of the ultrasonic tip CAUTION: Ultrasonic tips of third-party manufacturers in some cases don't offer a sufficient flow rate in conjunction with the NaCl function. Use only ultrasonic tips from Sirona. 4.5.9 Electric motor NOTE: Also observe the operating instructions for the different motors.
  • Page 70 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Brushless motors Brushless motors are designed as three-phase motors (without carbon brushes). They are characterized by precise controllability and longevity. Their speed range lies between 90 and 40,000 rpm (revolutions per minute).
  • Page 71 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.9.2 Setting the speed Selecting the speed with the quick setting keys The electric motor is removed from its holder. The Motor screen is displayed on the touchscreen. Touch one of the quick setting keys in the bottom line key briefly (< 0.5 s).
  • Page 72 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Setting the speed with function levels The electric motor is removed from its holder. The Motor screen is displayed on the touchscreen. Set the speed using the – and + keys.
  • Page 73: Turbine

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO NOTE: Audible warning signal during CCW rotation After you start the electric motor with the foot control, an audible warning signal sounds 6 times if counterclockwise rotation is activated.
  • Page 74 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Risk of scalding with SPRAYVIT (hose change) WARNING: After changing the SPRAYVIT hose, no cooling water for the SPRAYVIT heating cartridge flows until the hose is completely filled. The patient may be scalded by the emission of hot steam. The heating cartridge can overheat and be destroyed.
  • Page 75 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Settings made in the SPRAYVIT setup program always refer to the multifunctional syringe currently removed from the dentist or the assistant element. If both SPRAYVIT L multifunctional syringes are removed from their holders, the settings apply only to the multifunctional syringe of the dentist element.
  • Page 76: Sirosonic Tl Scaler

    Use the – and + keys to set the brightness. Preselecting the instrument light operating voltage The original Sirona halogen lamp is operated at 3.6 V. The operating voltage can be set to max. 5 V in order to adapt it to different lamps.
  • Page 77 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO SIROSONIC TL laser radiation The Laser Radiation warning symbol is displayed in the upper left-hand corner of the touchscreen in the Ultrasonic screen. The instrument light is generated by a powerful LED located at the instrument end of the hose.
  • Page 78: Sirotom Hf Electrosurgical Handpiece

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Setting the intensity with function levels The SIROSONIC TL scaler is removed from its holder. The Ultrasonic screen is displayed on the touchscreen. Set the intensity using the – and + keys.
  • Page 79 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.13.1 Safety information Improper operation and failure to observe precautions can cause serious accidents when working with the electrosurgical unit. Cardiac pacemakers (SIROTOM) WARNING: High frequency currents and fields may influence cardiac pacemakers.
  • Page 80 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.13.3 Setting the intensity Selecting the intensity with the quick setting keys The SIROTOM HF electrosurgical handpiece is removed from its holder. The Electrosurgery screen is displayed on the touchscreen.
  • Page 81 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Mod 4 Mod 2 Mod 0 NOTE: Selection of modulation type Always select Mod 0 for electrotomy! For coagulation, select modulated current type Mod 1 to 4 for the depth of crust based on experience.
  • Page 82 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Actuate the foot control. The HF electrosurgical handpiece is switched on. The symbol for nonionizing electromagnetic radiation is displayed on the left side of the touchscreen (illustration with quick setting keys). A continuous acoustic signal sounds (the volume can be adjusted by the service engineer).
  • Page 83 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Intensity = 50 Power curve Technical information Maximum output voltage peak – peak between handpiece and protective ground wire When cutting: 1400 V At max. coagulation: 1600 V Modulation frequency:...
  • Page 84: Implantological And Endodontic Treatments

    4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Explanation of the symbols and labels used Neutral electrode connection Neutral electrode with high frequency referenced to earth SIROTOM HF electrosurgical handpiece, type BF applied part Intermittent operation 25%...
  • Page 85 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.14.1 Treatment selection Switching the function on and selecting the treatment When the Treatment function is switched on, the treatment types "Endodontics" and "Implantology" are specified in two separate lists. The required treatment is selected from these lists.
  • Page 86 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO The Treatment Selection screen indicates which burr drive is assigned to the treatment type and which one could be used alternatively: Empty, gray circle Instrument cannot be used for the selected treatment type...
  • Page 87 Implantology function. Instruments from other manufacturers can lead to malfunctions. Outside instruments may be improperly calibrated for implantology. Use only the IMPLANT 20:1 contra-angle handpiece from Sirona for implantology. Check whether the reduction ratio on the touchscreen agrees with the value specified on the contra-angle handpiece being used.
  • Page 88 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO NOTE: Torque adjustment The maximum adjustable torque depends on the system motor and the speed settings. Incorrect speed and torque settings WARNING: Improperly selected speeds and torque values endanger the patient.
  • Page 89 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO The Implantology program is displayed on the touchscreen. Select the required implantology work step. Touch the previous or next work step key. The selected work step is displayed on the touchscreen. The settings saved in the work step are preset.
  • Page 90 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Preselecting NaCl rinsing, setting the flow rate, and activating the rinse function Preselecting NaCl rinsing, setting the flow rate, and activating the rinse function The NaCl rinsing function can be used to activate an NaCl jet to rinse the treatment area whenever the burr instrument is not running.
  • Page 91 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Use the – and + keys to set the number of work steps. The number of work steps is displayed on the left side: Implant 1... X. 4.5.14.2.9 Preparing the treatment center for sterile operation The requirements for sterile operation must be fulfilled for surgical interventions.
  • Page 92 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Touch the Sub-screen key. The Advanced Endodontics program is displayed. Use the ↑ and ↓ keys to select the file that you would like to use. The selected file is highlighted orange. The recommended maximum values of the selected file are displayed above the speed and torque values in fine gray print.
  • Page 93 The contra-angle handpiece is automatically checked during calibration. This includes a measurement of motor current at different speeds to assess the properties of the system. NOTE: Use only Sirona instruments to guarantee correct calibration. 61 93 556 D3509 D3509.201.01.02.02 19.09.2008...
  • Page 94 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO The Simple Endodontics program (shown here) or the Advanced Endodontics program is displayed on the touchscreen. The Advanced Endodontics program can be opened by touching the Sub-screen key (two cascaded rectangles).
  • Page 95 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO 4.5.14.3.5 Setting the direction of rotation The direction of rotation can be changed only with the motor stopped. Counterclockwise rotation is performed without torque limitation. The torque setting keys are hidden when counterclockwise rotation is selected.
  • Page 96 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Touch the Sub-screen key again. The Endodontics sub-screen is displayed. For endodontic treatments, the settings are made individually for each file. Use the ↑ and ↓ keys to select the file for which you would like to change the settings.
  • Page 97 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO NOTE: Automatic file system reset On completion of the Treatment function, the files that have been removed from the file system are reinserted. Changes made in the file system remain effective after the Treatment function has been completed only for customized endodontic treatments marked with a pencil symbol in the Treatment selection screen;...
  • Page 98 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Creating a new endodontic treatment Creating a new endodontic treatment The treatment center enables you to create up to five endodontic treatments. Touch the Create new endodontic treatment key.
  • Page 99 4 Operation Sirona Dental Systems GmbH Dentist element Operating Instructions TENEO Touch the button of an endodontic treatment that you would like to rename. The selected button is highlighted orange. Touch the Rename endodontic treatment key. A keyboard is displayed. The designation to be changed is displayed in the text box.
  • Page 100: Assistant Element

    4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO The Treatment administration screen is displayed. The selected file systems are displayed in the endodontic treatment list of the Treatment selection screen. Assistant element 4.6.1 Maximum load capacity The maximum load of the assistant element is 1.5 kg (3.3 lbs). Additionally, a skid-proof silicone mat can be placed on top of it.
  • Page 101 4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO The functions assigned to the keys can be switched on/off on the assistant element. The settings screens can be opened only on the touchscreen of the dentist element. To make settings, see "Fixed keys on the dentist element"...
  • Page 102: Suction Handpieces

    Make sure to hold the suction cannula in such a way that the cannula opening cannot attach itself to the oral mucous membranes by accident. Sirona recommends using spray aspirator cannulae with ventilation holes "see Spare parts, Consumables [ 174].
  • Page 103: Sprayvit L Multifunctional Syringe

    Spray aspirator You can angle the suction handpiece by turning it. The spray aspirator cannula from Sirona has a ventilation hole to ensure that the suction flow is not fully interrupted if it attaches itself to the oral mucosa A. This prevents backflow from the hose into the oral cavity if the cannula attaches itself.
  • Page 104: Mini L.e.d. Curing Light

    4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO 4.6.7 Mini L.E.D. curing light The curing light is used to cure composite fillings with short-wave light. 4.6.7.1 Safety information Mini L.E.D. laser light WARNING: The device contains an LED that falls under laser class L.E.D-Strahl...
  • Page 105 4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO 4.6.7.2 Connecting the Mini L.E.D. The Mini L.E.D. is connected to the assistant element in holder 1. Connect the supply cable (A) to the treatment center. Screw the hose coupling (B) onto the Mini L.E.D. (C).
  • Page 106 4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO Quick curing mode In the quick curing mode, the Mini L.E.D. operates at full power for 10 seconds. In this mode, the light intensity output is as follows: Sec.
  • Page 107: Hydrocolloid

    4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO 4.6.7.5 Technical data General Technical Data on Mini L.E.D. Model: Mini L.E.D. Weight of handpiece without hose: 105 g Dimensions: dia. 23 mm x 240 mm Power supply of handpiece:...
  • Page 108 4 Operation Sirona Dental Systems GmbH Assistant element Operating Instructions TENEO The assistant element is equipped with a hydrocolloid connection. Plug the two fast couplings (A) of the impression tray into the sockets (B) on the bottom of the assistant element in any order.
  • Page 109: Water Unit

    4 Operation Sirona Dental Systems GmbH Water unit Operating Instructions TENEO Both hydrocolloid connections are plugged into the bottom of the assistant element. Press and hold the Hydro key (> 2 s). The Hydrocolloid settings screen is displayed. Use the – and + keys to set the flow time.
  • Page 110: Adjusting The Water Amount For Flushing

    4 Operation Sirona Dental Systems GmbH Water unit Operating Instructions TENEO Filling the tumbler The tumbler must not be transparent. The tumbler must always be placed in the center of the area provided for Place the tumbler under the tumbler filler.
  • Page 111: Tray

    4 Operation Sirona Dental Systems GmbH Tray Operating Instructions TENEO Tray Maximum load capacity The maximum load is 1 kg (2.2 lbs). max. max. 1 kg 1 kg 2,2 lbs 2,2 lbs Adjusting the height with the locking brake The tray is supported to rotate on a height-adjustable support arm.
  • Page 112: Switching The X-Ray Viewer On/Off

    4 Operation Sirona Dental Systems GmbH X-ray viewer Operating Instructions TENEO X-ray viewer on the tray support arm 4.9.2 Switching the X-ray viewer on/off If the treatment center has no X-ray viewer, however, is equipped with a SIVISION monitor, the X-ray viewer key can be used to set the SIVISION monitor to the white screen mode;...
  • Page 113: Sirolux Fantastic Operating Light

    4 Operation Sirona Dental Systems GmbH SIROLUX FANTASTIC operating light Operating Instructions TENEO 4.10 SIROLUX FANTASTIC operating light The operating light is attached to a height-adjustable support arm. It can be easily adjusted with the handgrips to illuminate the treatment area. Brakes in the support arm hold the operating light in the position to which it has been adjusted.
  • Page 114: Sivision Digital Video System

    4 Operation Sirona Dental Systems GmbH SIVISION digital video system Operating Instructions TENEO If the composite function is switched on, the LED of the fixed key lights up on the dentist and assistant elements. The light intensity of the operating light is > 8,000 lux.
  • Page 115: Sirocam Digital Intraoral Camera

    4 Operation Sirona Dental Systems GmbH SIVISION digital video system Operating Instructions TENEO Attachment versions Monitor on lamp support tube The monitor can be rotated and swiveled. Monitor on tray arm The monitor can be rotated and swiveled. Patient collides with monitor Monitor on support arm The monitor can be rotated, swiveled and adjusted in height.
  • Page 116 4 Operation Sirona Dental Systems GmbH SIVISION digital video system Operating Instructions TENEO Intermittent operation of the intraoral camera CAUTION: The intraoral camera is designed for intermittent operation in dental offices. In continuous operation, the intraoral camera may become too hot for patients or users.
  • Page 117 4 Operation Sirona Dental Systems GmbH SIVISION digital video system Operating Instructions TENEO 4.11.2.4 Operation of the SiroCam digital intraoral camera The treatment center must be connected to an external PC for the display of video images of the SiroCam digital intraoral camera on the SIVISION monitor.
  • Page 118 4 Operation Sirona Dental Systems GmbH SIVISION digital video system Operating Instructions TENEO 4.11.2.5 Using hygienic protective sleeves Special hygienic protective sleeves (disposable) are available for the SiroCam digital intraoral camera. Prior to each application on a new patient, the intraoral camera must be covered with a new hygienic protective sleeve.
  • Page 119: External Pc

    4 Operation Sirona Dental Systems GmbH External PC Operating Instructions TENEO Characteristics of the image acquisition Lighting: 6 white light LEDs with light collector lens Image sensor: 1/4“ Color Interline Transfer CCD PAL pixels: 470.000 Effective pixels (PC) YUV: 720 x 576...
  • Page 120 4 Operation Sirona Dental Systems GmbH External PC Operating Instructions TENEO The SIVISION program is displayed on the touchscreen. Select the desired PC application from the left side of the touchscreen. The key of the selected PC application is highlighted orange and the corresponding control keys are displayed on the right side of the touchscreen;...
  • Page 121 4 Operation Sirona Dental Systems GmbH External PC Operating Instructions TENEO Rotate image Rotates the image 90° counterclockwise or clockwise. Contrast optimization filter This image filter analyses and optimizes the current grayscale distribution of an image. In this way, for instance, details within a very low-contrast, “faint”...
  • Page 122 4 Operation Sirona Dental Systems GmbH External PC Operating Instructions TENEO To mitigate high-contrast or high-interference effects in images, the contrast between neighboring pixels is reduced or averaged. The overall definition of the image is reduced. Sharpen image Contrasts between neighboring pixels are increased. This function helps to accentuate edges or contours.
  • Page 123: Open Usb Port

    An open USB port is located at the back of the dentist element. The upper slot is without function. WARNING: Only type BF medical devices according to IEC 6060-1, e.g. the Sirona XIOS USB intraoral X-ray system, may be connected to the USB port. WARNING: USB devices with their own voltage supply (e.g., via a power supply unit) may increase the working current.
  • Page 124: Configuring The Easytouch User Interface

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO Press and hold the Setup fixed key (> 2 s). Six setup programs are offered for selection. Key symbols of the six setup programs line by line from left to right:...
  • Page 125: Setting The Date And Time

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO Touch the small cross on the touchscreen with a blunt pen. The cross is displayed at another location on the touchscreen. Repeat this procedure until the cross no longer appears.
  • Page 126: Configuring Control Options

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO 4.13.4 Configuring control options This program allows for the configuration of the entire treatment center operation. Touch the Control options key in the setup program.
  • Page 127 4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO Field 1: Cursor control switched off Field 2: Cursor control switched on, without screen change Field 3: Cursor control switched on, with program change For more information, please refer to "Using the cursor control" [ 38].
  • Page 128 4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO 4.13.4.8 Linking the tumbler heater to the chair program A setting can be made so that the tumbler heater automatically switches off when the entry/exit position (0) chair program is activated. The tumbler heater switches back on as soon as the patient chair leaves the entry/exit position.
  • Page 129: Configure Instruments

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO If you deposit the spray aspirator in its holder while the suction flow is interrupted, the suction flow is automatically restarted when you pick it up again.
  • Page 130 4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO 4.13.5.1 Preselecting quick setting keys with SaveMode/ with DropMode or function levels Settings can be made in the instrument programs using either the quick adjustment keys (1...100) or two freely programmable function levels (E1, E2).
  • Page 131: Configuring The Network Connection

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO 4.13.6 Configuring the network connection Touch the Network connection key in the setup program. The sub-screen Network connection opens. It shows the current network configuration.
  • Page 132 4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO The Network connection sub-screen is displayed on the touchscreen. Touch the key at the end of the Subnet line. The Subnet mask screen is displayed.
  • Page 133: Opening The Service Domain

    4 Operation Sirona Dental Systems GmbH Configuration of the treatment center (setup) Operating Instructions TENEO 4.13.6.3 Switching the PC control on/off The treatment center control of the external PC can be switched on/off. This does not affect the network connection. When PC control is switched off, the SIVISION symbol is hidden on the program change key.
  • Page 134: Care And Cleaning Instructions For The Practice Team

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Basics Operating Instructions TENEO Care and cleaning instructions for the practice team Basics 5.1.1 Intervals To maintain the value and safe functioning of your treatment center, it is necessary to have it cared for, cleaned and disinfected by the practice team regularly.
  • Page 135: Care And Cleaning Agents

    Care and cleaning agents CAUTION: Approved Care and cleaning agents Use only care and cleaning agents which have been approved by Sirona! Care and cleaning agents You will find a list of all agents approved at the time of delivery in the documentation folder supplied with your treatment center.
  • Page 136: Surfaces

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Surfaces Operating Instructions TENEO Be careful not to touch the inside of the test container or the part of the tester to be immersed (with nutrient medium) prior to incubation.
  • Page 137: Disinfect The Easytouch

    Approved care and cleaning agents CAUTION: Approved care and cleaning agents Use only care and cleaning agents which have been approved by Sirona (see "Care and cleaning agents" [ 135]). Press and hold the Clean fixed key on the dentist element.
  • Page 138: Disinfecting The Tray

    Never place your fingers into the open receptacle of the tray. Approved care and cleaning agents CAUTION: Approved care and cleaning agents Use only care and cleaning agents which have been approved by Sirona (see "Care and cleaning agents" [ 135]). Hold the tray tightly.
  • Page 139: Disinfect, Clean And Care For The Upholstery

    5.2.5 Disinfect, clean and care for the upholstery CAUTION: Approved care and cleaning agents Use only care and cleaning agents which have been approved by Sirona for the upholstery; see "Care and cleaning agents". Disinfection: The upholstery, including the head support of the headrest, can be spray and wipe disinfected.
  • Page 140: Thermally Disinfect The Instrument Holder Of The Dentist Element

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Surfaces Operating Instructions TENEO Press one side of the head pad (A) inward from the outside (to unlock it) and remove it. The head pad can be snapped back into the headrest by applying slight lateral pressure.
  • Page 141: Thermally Disinfect The Instrument Holder Of The Assistant Element

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Motor holder A sterilizable motor holder is available for surgical procedures; see also "Preparing the treatment center for sterile operation" [ 91].
  • Page 142: Purge Water Lines (Purge Function)

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Activate the cuspidor flushing of the cuspidor bowl for at least one minute. 5.3.2 Purge water lines (purge function) To reduce the amount of germs, the water lines of the water carrying instruments of the dentist element and the SPRAYVIT multifunctional syringe of the assistant element are purged with water.
  • Page 143 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Setting the purge time and starting the purge function The purge time of the removed instruments can be set between 20 and 120 seconds.
  • Page 144: Automatically Purge Water Lines (Autopurge Function)

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Canceling the purge function In case of an error message, deposit the instruments in their holders or, during purging, the purge function can be canceled.
  • Page 145 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Touch the Autopurge function key. The Autopurge screen is displayed on the touchscreen. Setting the purge time and starting the autopurge function The purge time of the instruments may be set between 60 and 180 seconds.
  • Page 146 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Pull the tumbler holder (A) off of the water unit. Place the sanitation bowl with cover onto the cuspidor bowl. Make sure that the sanitation bowl is not contaminated.
  • Page 147 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO Insert the couplings of the treatment instruments as far as they will go or until they snap into the adapter.
  • Page 148: Care For, Disinfect And Sterilize The Treatment Instruments

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Instruments and instrument hoses Operating Instructions TENEO When the purge time has elapsed, the Set instrument down display appears. You now can now continue in one of two ways: Leave the instruments in the sanitation bowl The Autopurge function remains activated.
  • Page 149 Approved care and cleaning agents CAUTION: Approved care and cleaning agents Use only care and cleaning agents which have been approved by Sirona (see "Care and cleaning agents" [ 135]). Remove the connecting cable of the Mini L.E.D. by rotating the handpiece.
  • Page 150: Changing The Cotton Wool Roll On The Turbine Hose

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Vacuum system Operating Instructions TENEO Risk of scalding with SPRAYVIT (cleaning) WARNING: If the flow rate is insufficient, hot water may be emitted by the SPRAYVIT. The patient could thus be scalded.
  • Page 151: Cleaning And Disinfecting The Vacuum System

    Vacuum system Operating Instructions TENEO Approved care and cleaning agents CAUTION: Approved care and cleaning agents Use only care and cleaning agents which have been approved by Sirona (see "Care and cleaning agents" [ 135]). 134°C 273,2°F Suction cannula 3 min...
  • Page 152 Foaming cleaning agents often cause foam and water to be sucked into the dry suction system. This can cause damage to the suction machine. Use only care and cleaning agents which have been approved by Sirona, see "Care and cleaning agents" [ 135].
  • Page 153: Cleaning And Disinfecting The Suction Hoses

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Vacuum system Operating Instructions TENEO Rinsing out the cleaning agent and disinfectant Following the cleaning process, pour at least 1 liter of water into the cuspidor bowl.
  • Page 154: Thermodisinfecting Suction Hoses

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Vacuum system Operating Instructions TENEO Switch the treatment center off at the main switch. Pull the filter housings (B) off of the connectors on the assistant element.
  • Page 155: Components Of The Water Unit

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Components of the water unit Operating Instructions TENEO Plug the hose holders onto the rails in the (Miele) thermodisinfector and place the suction hoses on the wire basket provided for that purpose.
  • Page 156: Adding Disinfectant For Water

    Foaming cleaning agents often cause foam and water to be sucked into the dry suction system. This can cause damage to the suction machine. Use only care and cleaning agents which have been approved by Sirona, see "Care and cleaning agents" [ 135].
  • Page 157: Change The Water And Air Filters

    To reorder disinfectant for the water lines, see "Spare parts and consumables" [ 174]. CAUTION: Approved care and cleaning agents Use only disinfectants which have been approved for water lines by Sirona for the disinfection system; see "Care and cleaning agents" [ 135]! 5.5.4...
  • Page 158 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Components of the water unit Operating Instructions TENEO CAUTION: Amalgam residues must not enter the public sewage system. Amalgam is a mercury compound that is hazardous to water.
  • Page 159: Emptying The Sediment Container

    Place the container in the special packaging and ship it for disposal or authorize a certified waste management company. Installing the amalgam rotor Use only original Sirona accessories. Never use a used or recycled amalgam rotor. To reorder the amalgam rotor, see "Spare parts and consumables" [ 174].
  • Page 160: Cleaning The Filter Insert Of The Wet Suction Device

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Components of the water unit Operating Instructions TENEO Removing and emptying the sediment container Disinfect the vacuum system, see "Cleaning and disinfecting the vacuum system" [ 151].
  • Page 161 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Components of the water unit Operating Instructions TENEO As long as the treatment center is switched on, water mains in the vacuum line for technical reasons. Therefore, in order to clean the filter insert this water must be completely extracted beforehand.
  • Page 162: Sanitize The Treatment Center

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Open the flap (A) on the base of the water unit. Loosen the bayonet catch of the filter insert (B). Unscrew the filter insert from the filter housing of the wet suction device counterclockwise.
  • Page 163 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Sanitation comprises several phases and takes at least 24 hours. Sanitizing additional devices CAUTION: Additional devices connected to the external device connection must not be sanitized with the treatment center.
  • Page 164 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Symbol legend The status of the individual instruments is represented by symbols on the touchscreen as operational help and for support in case of an error. These...
  • Page 165 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Sanitation phase 1 is highlighted on the touchscreen. The Insert instruments in sanitation bowl display appears on the touchscreen. Pull the tumbler holder (A) off of the water unit.
  • Page 166 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Insert the SPRAYVIT valve body of the dentist element (G) in the right adapter and the SPRAYVIT valve body of the assistant element (H) in the left adapter as far as they will go (with valve lever pointing up and locking button pointing down).
  • Page 167 5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Sanitize the treatment center Operating Instructions TENEO Sanitation phase 3 – Treating water lines with disinfectant The water is pumped out of the water tank of the water unit via the tumbler filler.
  • Page 168: Foot Control And Connection Box

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Foot control and connection box Operating Instructions TENEO Sanitation phase 5 – Rinsing water lines with water The disinfectant is rinsed out of the SPRAYVIT hoses, instrument hoses and tumbler filling unit with water.
  • Page 169: Changing The Fuse Of The External Device Connection

    5 Care and cleaning instructions for the practice team Sirona Dental Systems GmbH Foot control and connection box Operating Instructions TENEO Removing and replacing the battery Remove the screws (A) from the bottom of the foot control. Remove the switch part (C) from the foot control.
  • Page 170: Maintenance By The Service Engineer

    6 Maintenance by the service engineer Sirona Dental Systems GmbH Inspection and maintenance Operating Instructions TENEO Maintenance by the service engineer Inspection and maintenance In order to ensure the operational safety and reliability of your treatment center and to avoid damage due to natural wear, annual inspection and maintenance must be performed on your treatment center.
  • Page 171: Safety Tests For Systems With Hf Surgical Equipment

    6 Maintenance by the service engineer Sirona Dental Systems GmbH Safety tests for systems with HF surgical equipment Operating Instructions TENEO Safety tests for systems with HF surgical equipment In Germany, medical equipment is subject to the provisions of the Ordinance on the Installation, Operation and Use of Medical Equipment (Medizinprodukte-Betreiberverordnung –...
  • Page 172: Malfunctions

    7 Malfunctions Sirona Dental Systems GmbH Error messages Operating Instructions TENEO Malfunctions Error messages Any error states of the treatment center that cannot be immediately recognized by the user and must nevertheless be corrected are displayed on the touchscreen. If an error state exists, this is indicated by a warning triangle (A) in the status line of the touchscreen.
  • Page 173: Remote Maintenance

    7 Malfunctions Sirona Dental Systems GmbH Remote maintenance Operating Instructions TENEO The warning triangle automatically disappears as soon as the error state has been eliminated. If it does not disappear, please inform your service engineer. Remote maintenance Functional description With remote maintenance, you enable the staff of your dental depot or our Customer Service Center, see "Contact data"...
  • Page 174: Spare Parts And Consumables

    A continuously updated list of approved agents can be downloaded from the Internet at "www.sirona.com". In the navigation bar, go to the menu items "SERVICE" / "Downloads" and then open the document "Care and cleaning agents".
  • Page 175 8 Spare parts and consumables Sirona Dental Systems GmbH Operating Instructions TENEO Hygienic protective covers for SiroCam digital intraoral camera The hygienic protective covers are sold by specialized dealers. Dürr Dental GmbH & Co. KG – Postfach 1264 – D-74302 Bietigheim- Bissingen Order No.: 2106-010-50 (500 pcs), 2106-010-51 (20 pcs)
  • Page 176: Technical Data

    9 Technical data Sirona Dental Systems GmbH Operating Instructions TENEO Technical data Model designation Model designation: TENEO Electrical connections, temperatures Power connection: 100 - 230 V AC ± 10% 50/60 Hz Rated current: 4.8 A at 230 V 9.6 A at 115 V...
  • Page 177 10 m Approval: See "Standards/Approvals“ [ 17]. Minimum requirements NOTE: Minimum requirements for the external PC See "Installation Instructions and System Requirements for PC Configuration" (Order No.: 61 94 075) SIVISION digital for TENEO. 61 93 556 D3509 D3509.201.01.02.02 19.09.2008...
  • Page 178: Disposal

    10 Disposal Sirona Dental Systems GmbH Operating Instructions TENEO Disposal Please observe the disposal regulations applicable in your country. We advise that this product is subject to the stipulations in the EC guideline 2002/96 governing waste electrical and electronic equipment and must be disposed of in line with the these special requirements within the European Union (EU).
  • Page 179: Overview Of All Function Keys

    11 Overview of all function keys Sirona Dental Systems GmbH Fixed keys Operating Instructions TENEO Overview of all function keys For operating instructions The following contains a brief description of the fixed keys on the dentist and assistant elements and the function keys on the touchscreen and to provide the reader with a quick overview of the significance of the symbols on the keys.
  • Page 180: Assistant Element

    11 Overview of all function keys Sirona Dental Systems GmbH Fixed keys Operating Instructions TENEO When the Flushing key is pressed (> 2 s), the Flushing Time settings screen appears. Freely selectable function e.g. call key freely available relay 230 VAC, 6 A (connected by the service engineer).
  • Page 181: Start Program

    11 Overview of all function keys Sirona Dental Systems GmbH Start program Operating Instructions TENEO Composite function Switches the composite setting for the operating light on/off. Reduced light intensity < 8,000 lux Operating light on/off Light intensity > 24,000 lux at 100% 11.2...
  • Page 182: Instrument Program

    11 Overview of all function keys Sirona Dental Systems GmbH Instrument program Operating Instructions TENEO Treatment function Activation of the implantology and endodontics functions Opening the sub-screen Used to access additional subordinate functions; see the following function keys: Purge water paths...
  • Page 183: Treatment Program

    11 Overview of all function keys Sirona Dental Systems GmbH Treatment program Operating Instructions TENEO Increases the intensity setting of the SIROSONIC TL scaler in steps of 20% referenced to the final value during treatment. With an intensity of 80%, only the maximum value of 100% can be selected.
  • Page 184: Implantology

    11 Overview of all function keys Sirona Dental Systems GmbH Treatment program Operating Instructions TENEO Open endodontics administration Used to access additional subordinate functions for endodontic treatments; see "Endodontic administration" [ 185]. 11.4.2 Implantology Setting the gear reduction of the contra-angle handpiece Adjusts the gear ratio to match the contra-angle handpiece being used.
  • Page 185: Endodontics

    11 Overview of all function keys Sirona Dental Systems GmbH Treatment program Operating Instructions TENEO 11.4.3 Endodontics Calibrating the burr drive A calibration must be performed each time you change or lubricate the contra- angle handpiece. The contra-angle handpiece is automatically checked during calibration. This includes a measurement of motor current at different speeds to assess the properties of the system.
  • Page 186: Other Dialogs

    11 Overview of all function keys Sirona Dental Systems GmbH Other dialogs Operating Instructions TENEO Copy endodontic treatment To reduce the amount of setting work required, you can copy an endodontic treatment and resave it under a different name. Then the settings can be changed.
  • Page 187: Flushing Settings Screen

    11 Overview of all function keys Sirona Dental Systems GmbH SIVISION program Operating Instructions TENEO Set filling time Setting the water tempering 11.5.4 Flushing settings screen Link flushing to mouth rinsing position S Following movement to mouth rinsing position S, the flushing function automatically switches on for the duration of the set flushing time.
  • Page 188 11 Overview of all function keys Sirona Dental Systems GmbH SIVISION program Operating Instructions TENEO Opening the sub-screen Used to access additional functions; see the following keys: SIDEXIS control key sub-screen Overview layout The opened image windows are scaled in the display area so that no scroll bars or as few scroll bars as possible must be displayed.
  • Page 189: Powerpoint

    11 Overview of all function keys Sirona Dental Systems GmbH Setup program Operating Instructions TENEO 11.6.2 PowerPoint Start PowerPoint PowerPoint is started on the external PC. The keys corresponding to the PowerPoint PC application are displayed on the right side of the touchscreen...
  • Page 190: Date And Time

    11 Overview of all function keys Sirona Dental Systems GmbH Setup program Operating Instructions TENEO Calibrating the touchscreen If the touchscreen is no longer able to precisely locate the position of a contact, it must be recalibrated. Touchscreen brightness 11.7.2...
  • Page 191: Instruments

    11 Overview of all function keys Sirona Dental Systems GmbH Setup program Operating Instructions TENEO Operating light The operating light is automatically switched on when the dentist element approaches and switched off when it moves away. Cuspidor bowl movement This can be used to set the cuspidor bowl so that it automatically moves inward when the mouth rinsing position (S) chair program is selected.
  • Page 192: Network Connection

    11 Overview of all function keys Sirona Dental Systems GmbH Setup program Operating Instructions TENEO SaveMode – The Memory key is displayed in the instrument programs: The settings made in the instrument program will be saved after the instrument is placed in its holder only if the Memory key was pressed and held beforehand (>...
  • Page 193: Index

    Sirona Dental Systems GmbH Index Operating Instructions TENEO Index Symbols Ball stopper ............64 ) ..................17 Bars, orange and blue ........... 39 Battery change, wireless foot control ......168 Numerics Bell key ..............61 4-way foot switch plate ........... 37 Blasting device ..............
  • Page 194 Sirona Dental Systems GmbH Index Operating Instructions TENEO Coolant ................65 Endodontics administration ........... 97 Couplings ..............69 Endodontics with SIROSONIC TL ......... 78 Cursor control ..........37 Entry/exit position 0 ........37 Cuspidor ..............155 ErgoMotion ..............52 Cuspidor bowl ............109 Error message ...............
  • Page 195 Sirona Dental Systems GmbH Index Operating Instructions TENEO Foot control Inserting a file in the sequence ........92 Battery (wireless foot control) ......36 Inserting an endo file in the sequence ......92 Chip blower ............. 37 Inspection and maintenance ........170 Cleaning ...............
  • Page 196 Sirona Dental Systems GmbH Index Operating Instructions TENEO IP address ..............131 Motor versions ............... 69 Motor-driven travel track ..........56 Mouth rinsing position S ......37 Key color ............... 35 Movement stop .............. 42 Key tone ..............124 Keys, missing ..............34 NaCl ..............
  • Page 197 Sirona Dental Systems GmbH Index Operating Instructions TENEO Programs ............... 24 SIUCOM plus ............114 Instrument program ......... 62 SIVISION digital ..........15 Settings screen ............35 Change to still/live image ........36 SIVISION program ..........119 Saves still image ............ 37 Start program ..........
  • Page 198 Sirona Dental Systems GmbH Index Operating Instructions TENEO Timer function ..............58 Water, microbiological check ........135 Torque acoustic signal ..........90 Wet suction ..............160 Torque limitation ........73 White balance for intraoral camera ......119 Total count tester ............135 White screen on the SIVISION monitor .......
  • Page 200 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMMU péê~ÅÜÉW==ÉåÖäáëÅÜ= mêáåíÉÇ=áå=dÉêã~åó aPRMVKOMNKMNKMOKMO NVKMVKOMMU ûKJkêKW= MMM=MMM páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W SN=VP=RRS=aPRMV c~Äêáâëíê~≈É=PN páêçå~=aÉåí~ä=póëíÉãë=ii` lêÇÉê=kç SQSOR=_ÉåëÜÉáã QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM dÉêã~åó `Ü~êäçííÉI=k`=OUOTP ïïïKëáêçå~KÅçã...

Table of Contents