Sirona INTEGO Operating Instructions Manual
Hide thumbs Also See for INTEGO:
Table of Contents

Advertisement

NMKOMNS
kÉï=~ë=çÑW
fkqbdl=L=fkqbdl=éêç=
fkqbdl=éêç=^ãÄáÇÉñíêçìë
léÉê~íáåÖ=fåëíêìÅíáçåë=Erp^F
båÖäáëÜ
Operating Instructions INTEGO / INTEGO turn, INTEGO pro / INTEGO pro turn
=

Advertisement

Table of Contents
loading

Summary of Contents for Sirona INTEGO

  • Page 1 NMKOMNS kÉï=~ë=çÑW fkqbdl=L=fkqbdl=éêç= fkqbdl=éêç=^ãÄáÇÉñíêçìë léÉê~íáåÖ=fåëíêìÅíáçåë=Erp^F båÖäáëÜ Operating Instructions INTEGO / INTEGO turn, INTEGO pro / INTEGO pro turn...
  • Page 3: Table Of Contents

    Sirona Dental Systems GmbH Table of Contents Operating Instructions (USA) INTEGO Table of Contents General Information....................Dear customer, .................... Contact information ..................Notes on these operating Instructions............1.3.1 General information on the operating Instructions ......1.3.2 Scope of these operating Instructions ..........
  • Page 4 Operating Instructions (USA) INTEGO Unit description......................Standards/Approvals ..................Technical data....................System overview INTEGO ................System overview INTEGO pro ..............System overview of INTEGO pro with Ambidextrous option ......Patient chair ....................Head support....................3.7.1 Flat headrest ..................3.7.2 Double-jointed head support ............
  • Page 5 Sirona Dental Systems GmbH Table of Contents Operating Instructions (USA) INTEGO Foot control ....................4.3.1 Pneumatic foot switch ..............4.3.2 C+ electronic foot switch ..............Patient chair ....................4.4.1 Safety instructions ................4.4.2 Safety stop ..................4.4.3 Triggering an immediate movement stop ........
  • Page 6 4.7.4 Stand-alone water supply..............136 4.7.4.1 Water supply for the INTEGO ........... 137 4.7.4.2 Water supply for the INTEGO pro ........139 4.7.5 Converting the Turn water unit for right and left-handed people..141 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 7 Sirona Dental Systems GmbH Table of Contents Operating Instructions (USA) INTEGO Swiveling tray holder ..................X-ray image viewer..................4.10 Operating light ....................4.10.1 Switching the operating light on/off ..........4.10.2 Setting the LEDlight brightness ............4.10.3 Setting the brightness and sensor control of the LEDview....
  • Page 8 Table of Contents Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO 5.2.4 Disinfect the tray ................185 5.2.5 Care for, clean, and disinfect upholstery .......... 186 5.2.6 Cleaning the bottom surface of the mount for the backrest component 5.2.7 Clean the foot switch................ 186 Instruments and instrument hoses ..............
  • Page 9 Sirona Dental Systems GmbH Table of Contents Operating Instructions (USA) INTEGO 5.5.9 Cleaning the filter insert of the wet suction device with cuspidor valve 5.5.10 Emptying the collector of the air jet pump ........Sanitizing...................... 5.6.1 Sanitizing with the fresh water bottle..........
  • Page 10: General Information

    These Operating Instructions are designed to assist you prior to initial use and whenever you require information later on. We wish you a great deal of success and pleasure with INTEGO / INTEGO pro. ®...
  • Page 11: Notes On These Operating Instructions

    ● INTEGO TS (Compact water unit and dentist element with hanging hoses) ● INTEGO CS (Compact water unit and dentist element with swivel arms) ● INTEGO pro TS (Comfort water unit and dentist element with hanging hoses) ● INTEGO pro CS (Comfort water unit and dentist element with swivel arms) The dental treatment units can be delivered from the factory with the Ambidextrous option.
  • Page 12: Other Valid Documents

    The instructions as well as any warning and safety information contained therein also must be observed. There are separate operating instructions for each of the following Sirona products: ● Treatment instruments and accessories...
  • Page 13: Indication And Contraindication

    Sirona Dental Systems GmbH 1 General Information Operating Instructions (USA) INTEGO 1.7 Indication and contraindication Indication and contraindication Indication The dental treatment unit is suitable for following treatments: Indication without implantology ● caries ● periodontitis ● endodontics ● misaligned teeth ● dental care (teeth cleaning, etc.) ●...
  • Page 14: Safety Instructions

    2 Safety instructions Sirona Dental Systems GmbH 2.1 Identification of the danger levels Operating Instructions (USA) INTEGO Safety instructions Identification of the danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in these operating instructions.
  • Page 15: On-Site Installation

    Alternatively, a self- sufficient water supply can also be installed. In addition, with the INTEGO an optional fresh water bottle, or with the INTEGO pro the empty tank for waterline treatment solution can be used as a water container. For dental...
  • Page 16: Connection To The Public Drinking Water System

    The INTEGO pro dental treatment unit, if it is equipped with a waterline treatment system, complies with the requirements of EN 1717 (free discharge with an air gap ≥...
  • Page 17: Trouble-Free Operation

    No restrictions apply when using salt blasting devices in connection with Suction of steel abrasives permissible Sirona dental treatment units. However, in such cases, make sure that the system is subsequently flushed with an adequate amount of water. 2.10 Patient chair Please observe the maximum load capacity for the patient chair.
  • Page 18: Intermittent Operation

    Unsuitable care and cleaning agents may corrode the surface of the unit or impair function. Use only care, cleaning and disinfecting agents approved by Sirona! For more information, see "Care, cleaning, and disinfecting agents" [ → 178]. 65 47 686 D3543...
  • Page 19: Care And Cleaning Instructions For The Practice Team

    For reasons of product safety, this product may be operated only with original Sirona accessories or third-party accessories expressly approved by Sirona. The user is responsible for any damage resulting from the use of non-approved accessories. If any units not approved by Sirona are connected, they must comply with the applicable standards, e.g.:...
  • Page 20: Electrostatic Discharge

    2 Safety instructions Sirona Dental Systems GmbH 2.19 Electrostatic discharge Operating Instructions (USA) INTEGO ray image viewer. Electromagnetic interference can often be reduced by operating the external HF surgical device with a neutral electrode. Turn on the dental treatment unit with the Clean button inactive, to avoid malfunction, see section "Clean button"...
  • Page 21: Dismantling/Installation

    Sirona Dental Systems GmbH 2 Safety instructions Operating Instructions (USA) INTEGO 2.20 Dismantling/Installation The amount of charge depends on several factors: The charge is: ● higher at low air humidity than at high air humidity, and ● higher with synthetic materials than with natural materials (clothing, floor coverings).
  • Page 22: Unit Description

    "Connection to the public drinking water supply" [ → 16] Original language of this document: German INTEGO / INTEGO pro bear the CE marking in accordance with the CE marking, INTEGO / INTEGO pro provisions of Council Directive 93/42/EEC of June 14, 1993 concerning medical devices.
  • Page 23 EN 1717; see also the chapter entitled "Connection to the public drinking water system" [ → 16]. ® INTEGO is a registered trademark of Sirona Dental Systems GmbH. Product name is a registered trademark, INTEGO 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 24: Technical Data

    3 Unit description Sirona Dental Systems GmbH 3.2 Technical data Operating Instructions (USA) INTEGO Technical data Model designation: INTEGO / INTEGO pro Model designation, power ratings Power connection: 100 – 240 V AC ± 10% 50/60 Hz Rated current: 3.3 A – 1.5 A at 100 – 240 V also max.
  • Page 25 Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.2 Technical data Transport and storage Temperature: -40 °C – +70 °C Operating and transport conditions 1060 conditions: (-40 °F – 158 °F) Relative humidity: 10% – 95% Air pressure: 500 hPa – 1,060 hPa Operating conditions: Ambient temperature: 10 °C –...
  • Page 26: System Overview Intego

    3 Unit description Sirona Dental Systems GmbH 3.3 System overview INTEGO Operating Instructions (USA) INTEGO System overview INTEGO The INTEGO dental treatment unit comprises the following main components: INTEGO TS dental treatment unit Patient chair Flat headrest (shown here) or double articulating headrest...
  • Page 27 Patient chair Flat headrest or double articulating headrest (shown here) Pneumatic foot switch or C+ electronic foot switch (shown here) INTEGO CS dentist element with swivel arms Compact or Comfort (shown here) assistant element Compact water unit Main switch and external device connection (optional) 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 28: System Overview Intego Pro

    Sirona Dental Systems GmbH 3.4 System overview INTEGO pro Operating Instructions (USA) INTEGO System overview INTEGO pro The INTEGO pro dental treatment unit comprises the following main components: INTEGO pro TS dental treatment unit Patient chair Flat headrest (shown here) or double articulating headrest...
  • Page 29 Patient chair Flat headrest or double articulating headrest (shown here) Pneumatic foot switch or C+ electronic foot switch (shown here) INTEGO pro CS dentist element with swivel arms Comfort assistant element Comfort water unit Main switch and external device connection (optional) 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 30: System Overview Of Intego Pro With Ambidextrous Option

    Operating Instructions (USA) INTEGO System overview of INTEGO pro with Ambidextrous option The INTEGO and INTEGO pro dental treatment units with the Ambidextrous option comprise the following main components: INTEGO pro TS dental treatment unit with Ambidextrous option Patient chair...
  • Page 31 Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.5 System overview of INTEGO / INTEGO pro with Turn option INTEGO pro CS dental treatment unit with Ambidextrous option Patient chair Flat headrest or double articulating headrest (shown here) Pneumatic foot switch or C+ electronic foot control (shown here)
  • Page 32: Patient Chair

    3 Unit description Sirona Dental Systems GmbH 3.6 Patient chair Operating Instructions (USA) INTEGO Patient chair The patient chair features a variety of adjustment options to optimally adjust the patient's position during treatment. Flat headrest (shown here) or double articulating headrest Backrest...
  • Page 33: Head Support

    Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.7 Head support Head support 3.7.1 Flat headrest The headrest extension can be pulled in or out depending on the patient's height. For upper jaw treatment, the magnetic head pad can be rotated and used as a neck rest.
  • Page 34: Foot Control

    3 Unit description Sirona Dental Systems GmbH 3.8 Foot control Operating Instructions (USA) INTEGO Foot control 3.8.1 Pneumatic foot switch With a pneumatic foot switch, the compressed air valve for activating the high-speed handpieces is integrated into the foot switch. The high-speed handpieces are therefore continuously adjustable.
  • Page 35: C+ Electronic Foot Switch

    Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.8 Foot control 3.8.2 C+ electronic foot switch The C+ electronic foot control can be set as a speed foot control or direct starter for electric motors and the SIROSONIC L scaler. The compressed air for turbines cannot be adjusted.
  • Page 36: Dentist Element

    Operating Instructions (USA) INTEGO Dentist element INTEGO and INTEGO pro can be equipped with a TS dentist element (with hanging hoses) or a CS dentist element (with whip arms). All functions of the dental treatment unit can be controlled via the control panel on the dentist element.
  • Page 37: Cs Dentist Element With Swivel Arms

    The instrument hoses are placed above the dentist element over the whip arms. Instrument holder (max. 5 instruments) EasyTouch for INTEGO and INTEGO pro Swiveling tray holder on the CS dentist element for one or two (shown here) standard trays...
  • Page 38: Instrument Positions

    • SiroCam AF+ The Standard 3-way syringe is only available for INTEGO. The INTEGO / INTEGO pro dental treatment units can be fitted with a maximum of two motors. A maximum of one SIROSONIC L scaler and one intraoral camera can be connected.
  • Page 39: User Interface

    Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.9 Dentist element 3.9.4 User interface The EasyTouch option is available for the INTEGO and INTEGO pro EasyTouch for INTEGO and INTEGO pro dental treatment units. INTEGO 10:45:03 Clean Touchscreen (pressure-sensitive user interface)
  • Page 40: Touch Screen

    3 Unit description Sirona Dental Systems GmbH 3.9 Dentist element Operating Instructions (USA) INTEGO Touch screen 3.9.4.1 The touchscreen displays virtual function keys according to the program selected. A list of all function keys is provided in the Appendix of this document, see "Overview of all function keys".
  • Page 41: Fixed Keys

    Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.9 Dentist element Fixed keys 3.9.4.2 Clean key Clean Pressing this key deactivates the complete user interface of the dentist element. Pressing it again > 3 s reactivates the user interface.
  • Page 42: Assistant Element

    The scope of functions of the assistant element is adapted to the dental assistant's field of activity. The INTEGO / INTEGO pro dental treatment unit and INTEGO pro with Ambidextrous option can be equipped with the Compact or Comfort assistant element.
  • Page 43 Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.10 Assistant element Comfort assistant element with dental treatment units without Ambidextrous option The Comfort assistant element is attached to the base of the patient chair by a support arm. It can be positioned so that the instruments can be reached by the dentist if he/she is performing treatment on his/her own.
  • Page 44 3 Unit description Sirona Dental Systems GmbH 3.10 Assistant element Operating Instructions (USA) INTEGO Comfort assistant element with dental treatment units with Ambidextrous option The Comfort assistant element is attached to the water unit with a support arm. It can be positioned so that the instruments can be reached by the dentist if he/she is performing treatment on his/her own.
  • Page 45: Instrument Positions

    • SiroCam F • SiroCam AF • SiroCam AF+ The Standard 3-way syringe is only available for INTEGO. A Mini L.E.D. curing light, an intraoral camera or an additional spray aspirator can be connected to the dental treatment unit. Changes to holder 2 can only be made by your service engineer.
  • Page 46: User Interface

    3 Unit description Sirona Dental Systems GmbH 3.10 Assistant element Operating Instructions (USA) INTEGO 3.10.2 User interface 3.10.3 Fixed keys on the assistant element Chair program S Fixed keys on the assistant element Mouth rinsing position with last-position memory function (programmable), seeProgramming chair positions" [ → 75]...
  • Page 47: Water Unit

    The Compact water unit can be operated with an air jet pump (Air Venturi) instead of a suction device. The heater for the treatment water is in the water unit. For the INTEGO, the water heater is optional.
  • Page 48: Compact Water Unit

    3 Unit description Sirona Dental Systems GmbH 3.11 Water unit Operating Instructions (USA) INTEGO 3.11.1 Compact water unit The Compact water unit is available only without a waterline treatment system. However, it can be equipped with a fresh water bottle for stand- alone water supply.
  • Page 49: Comfort Water Unit

    Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.11 Water unit 3.11.2 Comfort water unit The water unit can be optionally equipped with a waterline treatment system. It automatically adds a waterline treatment solution to the water that comes in contact with patients. This reduces the amount of bacteria in the water lines.
  • Page 50 3 Unit description Sirona Dental Systems GmbH 3.11 Water unit Operating Instructions (USA) INTEGO Suction hose connection for assistant element only tumbler filler Manually swiveling cuspidor (removable) Tumbler filler Cover of the storage tank for waterline treatment solution or stand-alone water supply Cleaning adaptor for water-carrying instruments of the dentist element for sanitizing and auto purge.
  • Page 51: Ambidextrous Water Unit

    Manually swiveling cuspidor (removable) Tumbler filler Cover of the storage tank for waterline treatment solution or stand-alone water supply (only with the INTEGO pro) Cleaning adaptor for water-carrying instruments of the dentist element for sanitizing and auto purge. Maintenance flap for accessing the cleaning agent tank to...
  • Page 52 Operating Instructions (USA) INTEGO Water unit INTEGO pro Ambidextrous with fresh water bottle With the INTEGO pro, the Ambidextrous water unit is available only without a waterline treatment system. However, it can be equipped with a fresh water bottle for stand-alone water supply. Switching between the fresh water bottle and public drinking water supply is another equipment option.
  • Page 53 Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.11 Water unit with the chemical suction hose cleaning option. For more information, see"Suction hose cleaning on the Turn water unit" [ → 207]. 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 54: External Device Connection

    3 Unit description Sirona Dental Systems GmbH 3.12 External device connection Operating Instructions (USA) INTEGO 3.12 External device connection External medical accessories can be connected to external device connection. They must comply with the requirements of the Medical Device Directive 93/42/EEC. NOTICE Additional devices, hydrogen peroxide up to 0.2‰, waterline treatment system, and fresh water bottle are optional...
  • Page 55 Sirona Dental Systems GmbH 3 Unit description Operating Instructions (USA) INTEGO 3.12 External device connection IEC outlet socket with power supply (max. 6 A) Fuse for inlet connector (6.3 A slow-blow) Quick coupling for air Quick coupling for water Pressure Flow rate Water 2.2 ±...
  • Page 56: Operation

    Sanitizing must be performed prior to initial startup of your dental treatment unit if the dental treatment unit is equipped with this option. In the INTEGO, the purging and sanitizing functions and the fresh water bottle are available as options. Both options must be present to sanitize the water lines.
  • Page 57: Switching The Dental Treatment Unit On/Off

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.1 Starting up the dental treatment unit 4.1.2 Switching the dental treatment unit on/off The dental treatment unit has a main switch with integrated fuse on the base of the chair. At the end of the working day, the dental treatment unit should be switched off to save energy and for safety reasons.
  • Page 58: Selecting A User Profile

    4 Operation Sirona Dental Systems GmbH 4.1 Starting up the dental treatment unit Operating Instructions (USA) INTEGO 4.1.3 Selecting a user profile The EasyTouch comfort user interface can manage up to four user profiles. This way, multiple users can operate the dental treatment unit without having to forego their own individual treatment and operation related settings.
  • Page 59: Concept Of The User Interface

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.2 Concept of the user interface Concept of the user interface 4.2.1 User interface 4.2.1.1 Virtual function keys The touchscreen displays virtual function keys according to the program selected. Required functions can be activated by touching the function keys with your finger.
  • Page 60: Status Column

    4 Operation Sirona Dental Systems GmbH 4.2 Concept of the user interface Operating Instructions (USA) INTEGO Sub-screens usually are generally hidden automatically after a certain Return period has elapsed. The key (return arrow) closes the opened sub-screen immediately. Settings screens In many cases, functions not only can be switched on or off, but also can 10:45:03 be set.
  • Page 61: Foot Control

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.3 Foot control Foot control The dental treatment unit can be operated with a pneumatic foot switch or the C+ electronic foot switch. 4.3.1 Pneumatic foot switch When the instrument is removed from the holder, on the EasyTouch, the instrument dialog is called up.
  • Page 62: C+ Electronic Foot Switch

    4 Operation Sirona Dental Systems GmbH 4.3 Foot control Operating Instructions (USA) INTEGO 4.3.2 C+ electronic foot switch The C+ electronic foot switch operating elements are assigned different functions depending on whether the instruments are all in place or an instrument is removed from its holder.
  • Page 63 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.3 Foot control 4-way foot control plate ✔ All instruments are in place. ➢ Move the 4-way foot switch plate to the left or right.  Left: Chair program 1 is started.
  • Page 64: Patient Chair

    4 Operation Sirona Dental Systems GmbH 4.4 Patient chair Operating Instructions (USA) INTEGO Patient chair 4.4.1 Safety instructions ü û Patient chair, chair movements CAUTION The free space under the patient couch and up to the water unit can be decreased due to chair movements.
  • Page 65: Safety Stop

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.4 Patient chair 4.4.2 Safety stop The dental treatment unit is equipped with various safety stops to prevent crushing and damage. The cutoff trigger points are shown in the following illustration: Display of triggered safety switches (all shown in one illustration)
  • Page 66: Triggering An Immediate Movement Stop

    4 Operation Sirona Dental Systems GmbH 4.4 Patient chair Operating Instructions (USA) INTEGO 4.4.3 Triggering an immediate movement stop You can stop the movement of the chair to a programmed position as follows: ➢ Touch one of the patient chair keys on the EasyTouch.
  • Page 67: Armrests

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.4 Patient chair 4.4.4 Armrests Armrests are available for the patient chair. The right armrest can be swiveled forward to facilitate getting in and out Both armrests can be swiveled of the chair. In dental treatment units with the Ambidextrous option, both armrests can be swiveled.
  • Page 68: Adjusting The Flat Headrest

    4 Operation Sirona Dental Systems GmbH 4.4 Patient chair Operating Instructions (USA) INTEGO 4.4.6 Adjusting the flat headrest The headrest extension can be pulled in or out manually depending on the patient's height. ➢ Pull the headrest out of the backrest or push it back in at the recessed grip A.
  • Page 69: Adjusting The Double Articulating Headrest

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.4 Patient chair 4.4.7 Adjusting the double articulating headrest The double articulating headrest is equipped with two rotary joints. They facilitate manual adjustment of head inclination for maxillary/mandibular treatments. The headrest extension can be pushed in or pulled out manually to adjust it to the height of the patient.
  • Page 70: Moving The Patient Chair Via Chair Programs

    IMPORTANT Cuspidor, manual, starting position Chair movements with cuspidor swiveled in INTEGO With the cuspidor bowl swiveled in, the chair cannot be moved. This prevents the patient from colliding with the cuspidor. Swing the cuspidor outward before initiating chair movement.
  • Page 71: Moving The Patient Chair To The Mouth Rinsing Position

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.4 Patient chair Moving the patient chair to the mouth rinsing position 4.4.8.2 The following functions are factory preset to be activated in the mouth rinsing position: ● The operating light switches off ●...
  • Page 72: Activating Other Chair Programs

    4 Operation Sirona Dental Systems GmbH 4.4 Patient chair Operating Instructions (USA) INTEGO Activating other chair programs 4.4.8.4 Via the touchscreen on the EasyTouch ✔ Start Instrument dialog is displayed on the touchscreen. ➢ Touch the key or the key briefly (< 2 s).
  • Page 73: Moving The Chair Manually

    IMPORTANT Cuspidor, manual, starting position Chair movements with cuspidor swiveled in INTEGO With the cuspidor bowl swiveled in, the chair cannot be moved. This prevents the patient from colliding with the cuspidor. Swing the cuspidor outward before initiating chair movement.
  • Page 74: Adjusting The Chair Height

    4 Operation Sirona Dental Systems GmbH 4.4 Patient chair Operating Instructions (USA) INTEGO Adjusting the chair height 4.4.9.2 Via the touchscreen on the EasyTouch ✔ Start Instrument dialog is displayed on the touchscreen. Adjust the chair height ➢ Touch the key. Via the 4-way foot switch ✔...
  • Page 75: Programming Chair Programs

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.4 Patient chair 4.4.10 Programming chair programs The four chair programs preset in the factory: ● Mouth rinsing position S ● Entry/exit position 0 ● 1 and 2 can be individually programmed for each of the four user profiles (A to D) on the EasyTouch.
  • Page 76: Dentist Element

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Dentist element 4.5.1 Maximum load capacity TS dentist element The maximum load on the TS dentist element without a tray holder is 1 kg (2.2 lbs). The maximum load on the TS dentist element with a tray holder is 2 kg (4.4 lbs).
  • Page 77: Positioning The Dentist Element

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element 4.5.2 Positioning the dentist element Dentist element on support arm, collision, manual movement WARNING The dentist element could be positioned within the movement range of the patient chair. Moving the patient chair may cause the patient to collide with the dentist element or its support arm.
  • Page 78 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Positioning the CS dentist element (standard position) In the standard position, the support arm of the CS dentist element is attached to the right mount of the Compact water unit and to the rear mount of the Comfort water unit.
  • Page 79 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Positioning the CS dentist element (special position) Alternatively, the support arm of the CS dentist element can be attached to the left mount on the Compact water unit (special position) and with the Comfort water unit to the front mount.
  • Page 80: Fixed Keys On The Dentist Element

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 4.5.3 Fixed keys on the dentist element An overview of the fixed keys on the EasyTouch can be found in the Description of Device, see "User interface" [ → 39].
  • Page 81: Placing The Instruments In Their Holders

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element 4.5.4 Placing the instruments in their holders Automatic opening of instrument dialogs On the EasyTouch, the respective instrument program appears on the touchscreen. If more than one instrument is removed from the holder, the speed or intensity or instrument dialog of the instrument removed first is displayed.
  • Page 82 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Cover for TS dentist element A cover can be purchased as an accessory for an instrument holder Cover which is not used. Insert the cover into an unassigned instrument holder. This prevents accidental deposit of an instrument in this holder.
  • Page 83: General Instrument Functions

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element 4.5.5 General instrument functions Settings for the coolant, instrument light, and foot switch can be made in the sub-screen of the instrument removed from the holder. The sub-screens vary according to the instrument removed. Functions not available for the respective instrument are not displayed in the sub- screen.
  • Page 84: Instrument Functions

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 4.5.5.1.2 Activating the chip blower With the chip blower, an air jet comes out of the burr instrument nozzle. ✔ A highspeed handpiece or motor is removed from the holder.
  • Page 85 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element 4.5.5.2.2 Switch spray on/off on the pneumatic foot switch. The spray is switched on when the foot switch is activated in combination with the instrument. The spray can be switched on/off via the foot switch.
  • Page 86 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO ✔ An instrument is removed from the holder. ➢ Press the left button of the C+ electronic foot switch.  If the preselected coolant is switched on, it will be displayed in the status column of the start and instrument dialog with a spray or air symbol.
  • Page 87 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element  The second sub-dialog is displayed. Direct starter/control foot switch 2. Touch the key.  If the key is highlighted gray, the direct starter function is switched on. If the key is highlighted orange, the speed control foot switch function is switched on.
  • Page 88: Saving Instrument Settings

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Saving instrument settings 4.5.5.3 DropMode When placing an instrument back in the holder, the instrument settings made are always saved in the user profile (DropMode). The next time the instrument is removed, the last settings made are available again.
  • Page 89: 3-Way Standard And Sprayvit E Syringe

    The 3-way syringe is used to clean the treatment areas and blow them dry. It supplies air and preheated water media. The heater for the treatment water is in the water unit. For the INTEGO, the water heater is optional. IMPORTANT Also note the SPRAYVIT operating instructions as well as the infomation on care of the 3-way syringe Standard in the section "Sterilizing the standard 3-way syringe"...
  • Page 90: Using The Standard 3-Way Syringe

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Using the standard 3-way syringe 4.5.6.2 ➢ Press the key A.  Air flows out of the instrument tip. Water ➢ Press the key B.  Water flows out of the instrument tip.
  • Page 91: Turbine / Air Motor / Other Air-Driven Instruments

    Operation of a highspeed handpiece with the pneumatic foot switch the drive air for the turbine can be regulated by the foot pedal. If instruments with a high air flow rate (e.g., SIROBoost from Sirona) are operated with the pneumatic foot switch, the operating pressure is reduced from 2.9 bar to 2.7 bar.
  • Page 92: Setting The Light Of The Highspeed Handpiece

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 4.5.7.2.2 Setting the highspeed handpiece light 1. Detach the turbine to be set from the holder. Sub-dialog 2. Press the fixed key. Highspeed handpiece  The sub-dialog is displayed on the touchscreen.
  • Page 93: Electric Motor

    (without carbon brushes). They are characterized by their precise controllability and durability. The speed range of the motors for INTEGO / INTEGO pro is between 1,200 and 40,000 rpm. If the dental treatment unit features the eControl option, the motor can be down-regulated to 100 rpm.
  • Page 94: Setting The Speed

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Setting the speed 4.5.8.2 Speeds are saved on the three favorite keys that can be accessed by pressing them. Individual speeds can be saved for each user profile on the favorite keys.
  • Page 95 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element IMPORTANT Electric motor, increments with favorite keys Increments The size of the increments depends on the speed range setting. From 100 to 1,000 rpm = 100 rpm increments (with eControl option)
  • Page 96: Setting The Direction Of Rotation

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Setting the direction of rotation 4.5.8.3 The direction of rotation can be changed only when the motor is at a standstill. Tip: After starting the electric motor with the foot switch, an audible warning signal sounds 6 times if counterclockwise rotation is activated.
  • Page 97: Integrated Torque Control

    Instruments from other manufacturers can lead to malfunctions. Third- party instruments may be improperly calibrated for endodontics. ➢ Use the Sirona ENDO 6:1 (from SN 6407 / July 2010) contra-angle handpiece for integrated torque control. 65 47 686 D3543...
  • Page 98 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Switching integrated torque control on/off 4.5.9.1 Switching torque control on Torque control is assigned to the burr drive removed from the holder. ✔ The desired electric motor for torque control is removed from the holder.
  • Page 99 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element ✔ Endodontics dialog is displayed on the touchscreen. 1.00 Endo 3 Sub-dialog 1. Press the fixed key. Endodontics  The sub-dialog is displayed. 1.00 Endo 3 Integrated torque control 2.
  • Page 100 The contra-angle handpiece is automatically checked during calibration. This includes a measurement of motor current at different speeds to assess the properties of the system. Calibration only with Sirona instruments CAUTION Use only Sirona instruments to guarantee correct calibration. ✔ Endodontics dialog Endodontics or the sub-dialog is displayed on the touchscreen.
  • Page 101 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Changing direction of rotation 4.5.9.3 The direction of rotation can be changed only with the motor stopped. Counterclockwise rotation is performed without torque limitation. The torque setting keys are hidden when counterclockwise rotation is selected.
  • Page 102 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Setting the speed and torque 4.5.9.5 With the torque control switched on, torque and speed of the contra-angle handpiece are indicated, but not of the motor. The control electronics of the bur drive calculate the motor control based on the specified contra- handpiece gear reduction and the set torque and speed.
  • Page 103 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Using the ApexLocator 4.5.9.6 ✔ The dental treatment unit is prepared for apex measurements using the instrument, see section "Preparing to use the ApexLocator" [ → 107]. ✔ Endodontics dialog...
  • Page 104 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 2. Use the – and + keys to set the required apex distance from 1.5 to 0. Stop If the distance is 0, the motor does not stop until it reaches the physiological apex.
  • Page 105 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Endodontics  The second sub-dialog is displayed. Torque signal and apex acoustic signals 2. Press the key.  If the key is marked in orange, the torque signal and the apex acoustic signals are switched on.
  • Page 106: Apexlocator

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 4.5.10 ApexLocator The ApexLocator is available only with the EasyTouch Comfort user interface. The ApexLocator can be used to measure the working length of the root canal file in endodontic treatments using electrical impedance.
  • Page 107: Preparing To Use The Apexlocator

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Preparing to use the ApexLocator 4.5.10.1 Apex adapter, mucosal electrode and file clamp The mucosal electrode and the file clamp are connected to the socket of the dentist element using the apex adapter. The socket is located on the left and to the rear, below the dentist element.
  • Page 108 Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO For endodontic treatments with the ApexLocator, the Sirona handpiece Sirona ENDO 6:1 handpiece or torque-limiting handpiece ENDO 6:1 (from SN 6407 / July 2010) is required when using the integrated torque control and a torque-limiting handpiece is required when using in the motor dialog (without torque control).
  • Page 109: Distance Display

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Distance display 4.5.10.2 The measured root canal depth is shown in the distance display on the touchscreen. A bar with 11 display levels shows the distance from the root canal file to the physiological apex (apical constriction). The root canal is divided into four colored sections in the distance display.
  • Page 110 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Green region The tip of the root canal file has reached the physiological apex. Red region The tip of the root canal file has pierced the physiological apex. The instrument overshoot is displayed.
  • Page 111: Beeps

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Beeps 4.5.10.3 In addition to the graphical distance display on the touchscreen, the position of the file in the root canal can also be indicated as an acoustic signal.
  • Page 112: Performing Manual Measurements With The File Clamp

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO Performing manual measurements with the file clamp 4.5.10.4 For endodontic examination, a manual measurement can be performed using the file clamp and a root canal file. ✔ The dental treatment unit is prepared for manual measurements using the file clamp, see section "Preparing to use the ApexLocator"...
  • Page 113: Endodontic Treatment With Apexlocator And Torque

    IMPORTANT ApexLocator, SIRONiTi APEX SIRONiTi APEX Only Sirona SIRONiTi APEX must be used to perform apex measurement using a torque-limiting handpiece! The electrical conductivity can only be ensured using this handpiece. SIRONiTi APEX is not available in the USA.
  • Page 114 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO  The set distance is displayed to the left of the – and + keys. The Stop Motor dialog preset motor stop position is displayed in the as a black triangle to the right of the distance display under the text "Stop".
  • Page 115 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element CAUTION Preventing incorrect measurements When performing the apex measurement, wear non-conductive gloves to avoid measurement errors caused by unwanted leakage current. During the measurement, the instrument must not come into contact with the patient's mucosa, metallic tooth restorations, or the mucosal electrode.
  • Page 116: Sirosonic L Scaler

    Ultrasonic handpiece, only Sirona tips CAUTION In some cases, ultrasonic tips from other manufacturers do not guarantee safe operation. ➢ Use only ultrasonic tips from Sirona. 4.5.11.2 Setting the intensity Intensities are saved on the three favorite keys that can be accessed by pressing them.
  • Page 117 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element Changing the intensity ➢ Press and hold the left or right favorite key (> 1 s).  The intensity is increased or reduced. The favorite keys are shaded gray for intermediate values.
  • Page 118 4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO  The key is highlighted orange. In the ultrasonic dialog, the 10:45:03 endodontics intensity is displayed instead of the ultrasonic intensity. Endo 65 47 686 D3543 D3543.201.03.02.23 10.2016...
  • Page 119: Mini L.e.d. Curing Light

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.5 Dentist element 4.5.12 Mini L.E.D. curing light The function is described in the chapter on the assistant element, see "Mini L.E.D. curing light" [ → 127]. 4.5.13 SiroCam F/AF/AF+ intraoral camera Functionality is described in the "SIVISION digital video system"...
  • Page 120: Timer Function

    4 Operation Sirona Dental Systems GmbH 4.5 Dentist element Operating Instructions (USA) INTEGO 4.5.14 Timer function A set time can be counted down to zero with the timer function. A time loop (automatic restart of the countdown) and an acoustic signal (when the set time has expired) can be added to each timer.
  • Page 121: Assistant Element

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element Assistant element 4.6.1 Maximum load capacity Compact assistant element The Compact assistant element has no tray. Assistant element, support arm CAUTION To prevent injuries caused by falling objects, never place anything on the support arm of the assistant element.
  • Page 122: Fixed Keys On The Assistant Element

    4 Operation Sirona Dental Systems GmbH 4.6 Assistant element Operating Instructions (USA) INTEGO 4.6.3 Fixed keys on the assistant element The functions assigned to the keys can be switched on/off on the assistant element. The operating contexts or setting screens can be accessed only on the dentist element.
  • Page 123: Flushing The Cuspidor

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element Flushing the cuspidor 4.6.3.3 The flushing function can be used for rough cleaning of the cuspidor during treatment. Flushing ➢ Press the fixed key.  The flushing function is activated for the preset flushing time.
  • Page 124: Suction Handpieces

    ➢ Make sure that you hold the suction tip in such a way that the opening cannot accidentally attach to the oral mucous membranes. Sirona recommends using spray aspirator cannulas with additional air intake, see "Spare parts, Consumables" [ → 258].
  • Page 125 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element Saliva ejector A curved tip that can be placed in the corner of the mouth is provided for saliva ejection. The suction flow can be stopped and regulated using the A rotating knob.
  • Page 126: 3-Way Standard And Sprayvit E Syringe

    4 Operation Sirona Dental Systems GmbH 4.6 Assistant element Operating Instructions (USA) INTEGO 4.6.5 3-way standard and SPRAYVIT E syringe The function is described in the chapter on the assistant element, see "Standard and SPRAYVIT E 3-way syringe" [ → 89]. 65 47 686 D3543...
  • Page 127: Mini L.e.d. Curing Light

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element 4.6.6 Mini L.E.D. curing light The curing light is used to cure composite material with short-wave light. 4.6.6.1 Safety instructions Curing light, laser radiation CAUTION The curing light contains powerful LEDs. In accordance with IEC 62471, they are classified in risk group 2 with the light bar removed.
  • Page 128: Connecting The Mini L.e.d

    4 Operation Sirona Dental Systems GmbH 4.6 Assistant element Operating Instructions (USA) INTEGO Connecting the Mini L.E.D. 4.6.6.3 The Mini L.E.D. is connected to the assistant element in holder 2. 1. Connect the supply cable A to the dental treatment unit. 2. Screw the hose coupling B onto the Mini L.E.D. C.
  • Page 129 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element Quick curing mode In the quick curing mode, the Mini L.E.D. operates at full power for 10 seconds. In this mode, the light intensity output is as follows: Sec.
  • Page 130: Operating The Mini L.e.d

    4 Operation Sirona Dental Systems GmbH 4.6 Assistant element Operating Instructions (USA) INTEGO Operating the Mini L.E.D. 4.6.6.5 IMPORTANT Curing light, contact with the material to be cured Contact with the material to be cured Make sure that the light guide never touches the material to be cured, as this may cause damage to the light guide and reduce its effectiveness.
  • Page 131: Technical Data

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.6 Assistant element Technical data 4.6.6.6 General Technical Data on Mini L.E.D. Model: Mini L.E.D. Weight of handpiece without hose: 105 g Dimensions: Dia. 23mm x 240mm Current consumption of handpiece: 5 V DC / 0.65 A...
  • Page 132: Water Unit

    4.7.2 Tumbler filling The heater for the treatment water is in the water unit. The water heater Water heater in the water unit, optional with INTEGO is optional in the INTEGO. 4.7.2.1 Tumbler filling Filling the tumbler 1.
  • Page 133: Tumbler Filling With Automatic Sensor Control

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit time when the mouth rinsing position chair program (S) is activated. 3. Use the – and + keys to set the filling time. 4.7.2.2 Tumbler filling with automatic sensor control...
  • Page 134: Flushing The Cuspidor

    4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO 4.7.3 Flushing the cuspidor The flushing function can be used for rough cleaning of the cuspidor during treatment. The cuspidor is always flushed using the public drinking water supply. It is not taken from the fresh water bottle or the tank for stand-alone water supply.
  • Page 135: Adjusting The Water Amount For Flushing

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit Adjusting the water amount for flushing 4.7.3.2 The water quantity and water pressure for flushing can be set using a valve. 1. Open the maintenance flap A on the base of the water unit.
  • Page 136: Stand-Alone Water Supply

    The stand-alone water supply functionality of the INTEGO is only available if the dental treatment unit is equipped with a fresh water bottle. The INTEGO pro dental treatment unit must be equipped with the integrated water waterline treatment system. In every mode, the cuspidor is flushed from the public drinking water supply.
  • Page 137: Water Supply For The Intego

    The fresh water bottle is treated with compressed air when it is attached to the holder. Unsuitable bottles such as beverage bottles can burst. ➢ Use only Sirona fresh water bottles! ➢ Please also observe the general safety instructions, see section "Fresh water bottle" [ → 18].
  • Page 138 4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO Switching between the public drinking water supply and fresh water bottle If the dental treatment unit is equipped with the optional fresh water bottle in the version which allows switching to the public drinking water supply, the water supply can be switched by turning a lever.
  • Page 139: Water Supply For The Intego Pro

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit Water supply for the INTEGO pro 4.7.4.2 In the Comfort and Ambidextrous water units, the stand-alone water supply should be set only as a temporary operating state if the public drinking water is contaminated and not as a permanent operating state.
  • Page 140 4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO  If there is still waterline treatment solution in the tank, it is rinsed Auto Refill water down the drain. This can take up to 6 minutes. The display then appears on the touchscreen.
  • Page 141: Converting The Turn Water Unit For Right And Left-Handed People

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit 4.7.5 Converting the Ambidextrous water unit for right and left- handed people CAUTION There must be no patient in the chair during conversion. The patient would otherwise collide with dental treatment unit components.
  • Page 142 4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO 2. If a tray is available on the dentist element: remove the tray from the holder. 3. If an additional holder has been installed on the dentist element: turn the additional holder inwards.
  • Page 143 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit 6. Move the dentist element right to the top. 7. Swivel the dentist element so that it is positioned closely in the grip area of the light support bar.
  • Page 144 4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO 9. If a Comfort assistant element is present; swivel the Comfort assistant element to the water unit underneath the cuspidor bowl. Turn the water unit CAUTION The water unit is now guided with a rotary motion to the opposite side of the dental treatment unit.
  • Page 145 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.7 Water unit 1. Press the foot pedal and move the water unit slightly upwards.  The patient chair will move automatically into a position in which the water unit can be rotated. An acoustic signal will also be given.
  • Page 146 4 Operation Sirona Dental Systems GmbH 4.7 Water unit Operating Instructions (USA) INTEGO 2. If a tray holder on the dentist element is present: remove the screw by hand and take the tray holder out of the dentist element. 3. Install both the tray holder and the additional holder on the other side of the dentist element.
  • Page 147: Swiveling Tray Holder

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.8 Swiveling tray holder Swiveling tray holder Maximum load capacity The TS dentist element can be equipped with a tray. The holder has room Tray on the TS dentist element with Turn option for two standard trays.
  • Page 148: X-Ray Image Viewer

    4 Operation Sirona Dental Systems GmbH 4.9 X-ray image viewer Operating Instructions (USA) INTEGO X-ray image viewer The TS and CS dentist elements can be equipped with an X-ray viewer. The ON/OFF switch is on the X-ray viewer. It switches off automatically after 10 minutes.
  • Page 149: Operating Light

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.10 Operating light 4.10 Operating light The operating light is attached to a multi-jointed support arm. It can be Operating lights LEDlight, LEDview and LEDviewPLUS easily adjusted to illuminate the treatment area using the handles. Brakes in the support arm hold the operating light in the position to which it has been adjusted.
  • Page 150: Switching The Operating Light On/Off

    4 Operation Sirona Dental Systems GmbH 4.10 Operating light Operating Instructions (USA) INTEGO 4.10.1 Switching the operating light on/off Operating light Repeatedly press the fixed key to set the following switching positions at the assistant element: 1. Switched on: The operating light is switched on at the preset brightness level.
  • Page 151: Setting The Brightness, Color Temperature And Sensor Control Of The

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.10 Operating light  If the key is highlighted in orange, the operating light can be controlled with the contactless sensor. The keys for adjusting the operating distance are displayed. 4. Use the – and + keys to set the desired operating distance (5 levels).
  • Page 152: X-Ray Tube Unit

    4.11 X-ray tube unit Operating Instructions (USA) INTEGO 4.11 X-ray tube unit The dental treatment units INTEGO and INTEGO pro can be equipped PLUS with the HELIODENT X-ray tube unit. No X-ray tube unit is available for dental treatment units with the Ambidextrous option.
  • Page 153: Sivision Digital Video System

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.12 SIVISION digital video system 4.12 SIVISION digital video system The SIVISION digital video system enables intraoral and extraoral images to be made. The SiroCam F / AF / AF+ intraoral camera generates digital image data which can be transmitted via a USB 2.0 port (high-speed Universal Serial Bus) to a connected PC and stored there.
  • Page 154: Sivision Monitor

    4 Operation Sirona Dental Systems GmbH 4.12 SIVISION digital video system Operating Instructions (USA) INTEGO 4.12.1 SIVISION monitor 22" AC monitor The monitor is equipped with loudspeakers. There is an IEC socket on the back of the monitor for the power supply. Please refer to the operating instructions for the 22"...
  • Page 155: Sirocam F / Af / Af+ Intraoral Camera

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.12 SIVISION digital video system 4.12.2 SiroCam F / AF / AF+ intraoral camera Safety instructions 4.12.2.1 The SiroCam F / AF / AF+ intraoral camera is a sensitive optical instrument and must therefore always be handled with care.
  • Page 156: Connecting The Sirocam F / Af / Af+ Intraoral Camera

    4 Operation Sirona Dental Systems GmbH 4.12 SIVISION digital video system Operating Instructions (USA) INTEGO Connecting the SiroCam F / AF / AF+ intraoral camera 4.12.2.3 Connecting the intraoral camera to the TS dentist element Depending on the equipment version, the intraoral camera can be placed at instrument position five or in the additional holder.
  • Page 157 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.12 SIVISION digital video system Connecting the intraoral camera to the assistant element The intraoral camera can be operated at the second instrument position of the assistant element. The camera connection is located underneath the assistant element instead of the connection for the curing light.
  • Page 158: Operating Sirocam F / Af / Af+ Intraoral Camera

    4 Operation Sirona Dental Systems GmbH 4.12 SIVISION digital video system Operating Instructions (USA) INTEGO Operating SiroCam F / AF / AF+ intraoral camera 4.12.2.4 An external or internal PC is required in order to display the video images of the SiroCam F / AF / AF+ intraoral camera on the SIVISION monitor.
  • Page 159 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.12 SIVISION digital video system 4.12.2.4.3 Using the camera with SI Video Using SI Video, up to four still images can be generated with the SiroCam F / AF / AF+ intraoral camera. These can be displayed on the SIVISION monitor either as a sequence of single images or simultaneously as a quad image.
  • Page 160 4 Operation Sirona Dental Systems GmbH 4.12 SIVISION digital video system Operating Instructions (USA) INTEGO Selecting the next quadrant In order to produce another still image, another quadrant must be selected. If a still image is already contained in the desired quadrant, it can be replaced by a new image.
  • Page 161 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.12 SIVISION digital video system 4.12.2.4.4 Using the camera with SIDEXIS Besides the display and processing of X-ray images, SIDEXIS XG or SIDEXIS 4 can be used additionally as a video application for the SiroCam F / AF / AF+ intraoral camera.
  • Page 162: Technical Camera Data

    4 Operation Sirona Dental Systems GmbH 4.12 SIVISION digital video system Operating Instructions (USA) INTEGO Generating a still image ✔ The live image is displayed on the SIVISION monitor. 1. Step on the foot pedal.  The display switches from live to still image.
  • Page 163: Operation With A Pc

    / SIVISION connect" manual. IT network CAUTION Integrating the INTEGO / INTEGO pro into an IT network that includes other devices can lead to previously unknown risks. The following changes to the IT network can lead to new risks: •...
  • Page 164: Sivision Program

    4 Operation Sirona Dental Systems GmbH 4.13 Operation with a PC Operating Instructions (USA) INTEGO 4.13.1 SIVISION program Various PC applications of the PC can be started and operated in the SIVISION program. You can select the PC applications to be operable via the dental treatment unit in SIUCOM plus.
  • Page 165: Communication With The Media Player

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.13 Operation with a PC The dental treatment unit starts the PC applications automatically. An orange square located in front of the respective PC application on the M.player touchscreen indicates whether the application has been started and is ready for operation on the PC.
  • Page 166: Communication With Sidexis

    4 Operation Sirona Dental Systems GmbH 4.13 Operation with a PC Operating Instructions (USA) INTEGO Communication with SIDEXIS 4.13.1.4 The SIDEXIS PC application enables you e.g. to display X-ray and intraoral camera images and transmit them to the SIVISION monitor. The live image of the SiroCam F / AF / AF+ intraoral camera is displayed in SIDEXIS and can be saved as a still image in the patient database.
  • Page 167 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.13 Operation with a PC Overview layout The opened image windows are scaled in the display area so that no scroll bars or as few scroll bars as possible must be displayed. The image windows are arranged without overlapping.
  • Page 168 4 Operation Sirona Dental Systems GmbH 4.13 Operation with a PC Operating Instructions (USA) INTEGO Filter black dots Single pixel errors may occur when taking digital X-rays. These pixel errors appear as individual black dots when the optimum resolution (100%) is selected. They are removed by SIDEXIS.
  • Page 169: Usb Interfaces

    USB interface, only units of type BF CAUTION Only type BF medical devices and applied parts according to IEC 60601-1, e.g. the Sirona XIOS XG USB module intraoral X-ray system, may be connected to the USB interface. Type BF USB interface, only units without power supply unit CAUTION USB devices with their own voltage supply (e.g., via a power supply unit)
  • Page 170: Configuration Of The Dental Treatment Unit (Setup)

    4 Operation Sirona Dental Systems GmbH 4.14 Configuration of the dental treatment unit (setup) Operating Instructions (USA) INTEGO 4.14 Configuration of the dental treatment unit (setup) Various dental treatment unit functions can be individually configured via the Setup settings. The dental treatment unit can therefore be adapted to match each user's personal method of treatment.
  • Page 171: Setting The Time And Date

    Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.14 Configuration of the dental treatment unit (setup) IMPORTANT Missing function keys Missing function keys Function keys for functions which the dental treatment unit equipment does not include are not displayed on the touchscreen.
  • Page 172: Configuring Control Options

    4 Operation Sirona Dental Systems GmbH 4.14 Configuration of the dental treatment unit (setup) Operating Instructions (USA) INTEGO 4.14.3 Configuring control options Operation of the entire dental treatment unit operation can be configured in this dialog. Control options ➢ Touch the key in the setup program.
  • Page 173 Sirona Dental Systems GmbH 4 Operation Operating Instructions (USA) INTEGO 4.14 Configuration of the dental treatment unit (setup) Coupling suction to the 4-way foot switch. 4.14.3.4 If the dental treatment unit is equipped with a position selector valve for the suction system, it can be set so suction flow can be interrupted or restarted by moving the 4-way foot control switch at the base of the chair in any direction.
  • Page 174 4 Operation Sirona Dental Systems GmbH 4.14 Configuration of the dental treatment unit (setup) Operating Instructions (USA) INTEGO Adjusting the cleaning agent mixture for chemical suction hose 4.14.3.8 cleaning The chemical suction hose cleaning option is only available for the INTEGO pro.
  • Page 175: Configuring The Network Connection

    MAC address of the center are shown. Intego Nr 2 Name Call in your data processing specialist for network configuration. Ethernet Network configuration is described in detail in the "INTEGO / INTEGO pro 13-E7-15-31-A3-0C installation instructions". 4.14.5 Opening the service function The Service domain is intended to be used only by service engineers.
  • Page 176: Care, Cleaning And Maintenance By The Practice Team

    5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.1 Basics Operating Instructions (USA) INTEGO Care, cleaning and maintenance by the practice team Basics Handling mainly involves the following steps: ● Cleaning ● Disinfection ● Sterilization if possible It is recommended to clean the unit as soon as possible after use.
  • Page 177 [ → 235] Check the message system of the amalgam separator [ → 227] For a quick overview of the work involved, see the “Maintenance, cleaning, and disinfection schedule” for the INTEGO / INTEGO pro dental treatment unit. 65 47 686 D3543...
  • Page 178: Care, Cleaning, And Disinfecting Agents

    Approved care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona! For a continuously updated list of approved agents, please visit Care, cleaning, and disinfecting agents, with REF number "www.sirona.com"...
  • Page 179: General Handling Instructions

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.1 Basics 5. Immerse the tester in the filled container for 30 seconds.  The cardboard disk with the culture medium will now absorb 1 ml of the water sample.
  • Page 180: Inspection, Maintenance And Testing

    Sterilization Sterilization may be done for components that are marked accordingly. Sirona recommends sterilization in a steam sterilizer (autoclave) according to ISO 13060, Class B (e.g., DAC PREMIUM/DAC PROFESSIONAL). The sterilization must be carried out with a multiple fractionated suction system (Class B sterilizer).
  • Page 181: Surfaces

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.2 Surfaces Surfaces 5.2.1 Clean/disinfect surfaces The surfaces can be disinfected by spraying and wiping with surface disinfectants. NOTICE Surfaces, medication Drugs have a chemical reaction with the surface of the unit.
  • Page 182: Disinfect User Interfaces

    NOTICE Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. Clean 1. Actuate the fixed key on the dentist element.
  • Page 183: Sterilize Silicone Mats And Handle Covers

    Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. The dentist element features a removable silicone mat and silicone covers for the handles.
  • Page 184 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.2 Surfaces Operating Instructions (USA) INTEGO Assistant element The silicone mat of the Comfort assistant element is identical with that of the CS dentist element. 1. Switch the dental treatment unit off and remove the suction hoses and instruments from the holders of the assistant element.
  • Page 185 NOTICE Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. 1. Hold the tray tightly. 2. Open the lock by swiveling the lever downwards.
  • Page 186 Operating Instructions (USA) INTEGO 5.2.5 Care for, clean, and disinfect upholstery Special care, cleaning, and disinfecting agents are recommended by Sirona for the care, cleaning, and disinfection of the upholstery. NOTICE Care, cleaning, and disinfecting agents, reference Approved care, cleaning, and disinfecting agents Use only agents approved by Sirona for the upholstery, see"Care,...
  • Page 187 ● the used instruments after each patient ● At the end of the work day With the INTEGO pro dental treatment unit, it is also possible to automatically purge the water lines, see "Automatically purge water lines (autopurge function)". [ → 191].
  • Page 188 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO 2. Set all of the instruments to be purged to their maximum water flow max. rate. The water regulators under the instrument holder must be turned counterclockwise.
  • Page 189 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.3 Instruments and instrument hoses Error message: Refill water (only for stand-alone water supply) Refill water If the display appears after the purge function has been...
  • Page 190 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO CAUTION Do not purge more than two burs simultaneously. If the dental treatment unit features the option of a third burr drive, the water flow rate is reduced when purging simultaneously.
  • Page 191 5.3 Instruments and instrument hoses 5.3.3 Automatically purge water lines (autopurge function) The autopurge function is only available on the INTEGO pro dental treatment unit. The autopurge function enables automatic purging of all water-carrying instruments in the dentist element, of the 3-way SPRAYVIT E syringe in the dentist and assistant elements and of the tumbler filling.
  • Page 192 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO Start  The sub-dialog is displayed. Auto Aqua Apex Dist Setup Autopurge function 2. Touch the key. Auto Error message: Deposit instruments...
  • Page 193 SPRAYVIT E: valve lever in the up position, locking knob in the down position). Also for INTEGO pro CS: Move the swivel arm of the instruments to be purged into the operating position so that the weight of the instrument hoses keeps them in this position.
  • Page 194 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO IMPORTANT Pinching the instrument hoses Be careful not to pinch the instrument hoses when inserting the instruments. With dental treatment units with the Ambidextrous option: convert the water unit to the left side so that the adapters on the water unit point towards the patient chair, see "Converting the Turn water unit for right-...
  • Page 195 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.3 Instruments and instrument hoses ➢ Remove the instruments from the water unit and put them back in place.  When all of the instruments have been put in the holders, the Purge function activated display disappears.
  • Page 196 5.3.4 Purging water lines manually With the INTEGO dental treatment unit, the purge and sanitize function is optional. If this function is not available, purging of the water lines must be carried out manually. The water-carrying instruments of the dentist element, the 3-way syringe of the dentist and assistant element and the tumbler filling must be purged.
  • Page 197 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.3 Instruments and instrument hoses 5. Activate the spray. Toggle the switch on the pneumatic foot switch to the right. Activate the left key on the C+ electronic foot control.
  • Page 198 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO 5.3.5 Lubricate, disinfect/sterilize the treatment instruments Treatment instruments 5.3.5.1 The procedures required for the following treatment instruments are described in the following separate operating instructions: ●...
  • Page 199 Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. Disconnect the mucosal electrode from the connection cable. The metal hook can be sterilized, and the connection cable can be disinfected by wiping.
  • Page 200 Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. 1. Remove the connection cable of the Mini L.E.D. by turning the 132°C –...
  • Page 201 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.3 Instruments and instrument hoses 5.3.6 Change the cotton wool roll on the turbine hose and oil collector Return air containing a small amount of highspeed handpiece oil is emitted at the unit end of the highspeed handpiece hose.
  • Page 202 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.3 Instruments and instrument hoses Operating Instructions (USA) INTEGO Oil collector The CS dentist element is also equipped with an oil collector. It is located below the instrument connections and collects any liquids that leak out.
  • Page 203 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.4 Vacuum system Vacuum system 5.4.1 Purge the vacuum system. If the dental treatment unit is equipped with the suction hose cleaning option, proceed according to the instruction in section "Cleaning the suction hoses"...
  • Page 204 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.4 Vacuum system Operating Instructions (USA) INTEGO Cleaning the suction hose on the Compact water unit 5.4.2.1 In the Compact water unit, the suction hose cleaning is optional. The suction hose cleaning option is not available in combination with an air jet pump (Air Venturi).
  • Page 205 ➢ Do not fill DENTOSEPT P waterline treatment solution into the cleaning agent tank for chemical suction hose cleaning! Use only "Agents for the suction lines" approved by Sirona, see Care, cleaning and disinfecting agents" [ → 178]. 65 47 686 D3543...
  • Page 206 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.4 Vacuum system Operating Instructions (USA) INTEGO 1. Open the maintenance flap on the base of the water unit. The cleaning agent tank for chemical suction hose cleaning is located on the left side.
  • Page 207 Suction hose cleaning on the Ambidextrous water unit 5.4.2.3 With the INTEGO pro dental treatment unit, the Ambidextrous water unit is always equipped with an adapter for the suction hose cleaning function. This can be used to purge the suction hoses consecutively. A cleaning agent is automatically added to the water if the dental treatment unit is equipped with the chemical suction hose cleaning option.
  • Page 208 Sirona Dental Systems GmbH 5.4 Vacuum system Operating Instructions (USA) INTEGO Refill cleaning agent (for the INTEGO pro with chemical suction hose cleaning option) When the adjacent display appears in the status column of the touchscreen, the cleaning agent for cleaning the suction system is almost all gone.
  • Page 209 Central supply for chemical suction hose cleaning 5.4.2.4 For clinical use, INTEGO / INTEGO pro dental treatment units can be fitted with a central cleaning agent supply for chemical suction hose cleaning. The CDS 60 system of Dürr Dental is intended for this purpose.
  • Page 210 NOTICE Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. NOTICE Vacuum system, foaming cleaning agents Domestic cleaning agents foam up.
  • Page 211 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.4 Vacuum system 5. Remove the suction tips from the suction hoses. 6. Set maximum suction flow on the suction handpieces. 7. Attach the adapter C to the saliva ejector.
  • Page 212 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.4 Vacuum system Operating Instructions (USA) INTEGO Rinsing the cleaning agent 1. Following the cleaning process, pour at least 1 liter of water into the cuspidor.  The water is drawn off, thus preventing any cleaning agent residues from remaining in the suction hoses.
  • Page 213 Rubber materials such as e.g. O-rings are corroded by unsuitable greases. ➢ Do not under any circumstances use vaseline or silicone greases. ➢ Use only greases approved by Sirona. 1. Detach the handpiece of the spray aspirator and the saliva ejector No surgical suction device option from the suction hoses.
  • Page 214 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.4 Vacuum system Operating Instructions (USA) INTEGO 5.4.5 Empty the central suction sieve Depending on the options, there is a central suction sieve in the Compact water unit or Comfort assistant element to retain solid materials (e.g.
  • Page 215 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.4 Vacuum system Emptying the central suction sieve in the Comfort assistant element 1. Open the cover on the suction sieve on the assistant element and remove it.
  • Page 216 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO Components of the water unit 5.5.1 Clean the gold trap The gold trap retains larger solid particles to prevent them from being washed down the drain in the cuspidor bowl.
  • Page 217 Foaming cleaning agents often cause foam and water to be sucked into the dry suction system. This can cause damage to the suction machine. ➢ Use only care, cleaning and disinfecting agents approved by Sirona, see"Care, cleaning, and disinfecting agents" [ → 178].
  • Page 218 Use the same agent as for the suction lines. NOTICE Care, cleaning, and disinfecting agents Approved care, cleaning, and disinfecting agents Use only care, cleaning and disinfecting agents approved by Sirona, see "Care, cleaning, and disinfecting agents" [ → 178]. NOTICE Vacuum system, foaming cleaning agents Domestic cleaning agents foam up.
  • Page 219 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 2. Fill the cuspidor with the cleaning solution and leave it to take effect. Observe the reaction time specified for the cleaning solution by the manufacturer.
  • Page 220 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 5.5.4 Refilling DENTOSEPT P waterline treatment solution The Comfort and Ambidextrous water units can be optionally equipped waterline treatment system option with the Comfort and Turn water unit with a waterline treatment system.
  • Page 221 Disinfectants for water lines Approved care, cleaning, and disinfecting agents Use only disinfectants which have been approved for water lines by Sirona for the waterline treatment system; see "Care, cleaning, and disinfecting agents" [ → 178]. 65 47 686 D3543...
  • Page 222 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 5.5.5 Change the water and air filters If you notice any changes in media flows, check the water and air filters for permeability.
  • Page 223 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 5. Reinsert the rubber ring E in the screw-on cap B, C. Then plug on the filter D as shown in the drawing.
  • Page 224 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 5.5.6 Change the amalgam rotor Amalgam residues and other solid particles are trapped in the amalgam rotor according to the centrifugal principle.
  • Page 225 6. Place the container in the special packaging and ship it for disposal or authorize a certified waste management company. Installing the amalgam rotor Use only original Sirona accessories. Never use a used or recycled amalgam rotor. To reorder the amalgam rotor, see "Spare parts and consumables"...
  • Page 226 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 3. Hold the lower part of the amalgam separator B so that the latching noses of the bayonet catch are positioned transverse to the water unit.
  • Page 227 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 5.5.7 Check the message system of the amalgam separator An electronic control monitors the function of the amalgam separator. SIt detects any mechanical blocking or failure of the drive motor.
  • Page 228 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO  The service dialog is shown. Amalg Test Test Info Amalg 4. Test the message system. Press and hold the key for an extended period.
  • Page 229 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 5.5.8 Empty the sediment container In addition to other solid particles, a large proportion of the amalgam residues are trapped in the sediment container by gravitational force.
  • Page 230 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 1. Open the flap A on the base of the water unit. 2. Loosen the bayonet catch by turning the sediment container B counterclockwise.
  • Page 231 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 2. Hold the sediment container B so that the latching noses of the bayonet catch are positioned transverse to the water unit. Rotate the sediment container B clockwise.
  • Page 232: Cleaning The Filter Insert Of The Wet Suction Device With Cuspidor

    5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 5.5.9 Cleaning the filter insert of the wet suction device with cuspidor valve The automatic separator and amalgam separator / sediment container or air jet pump are not installed in the water unit for standard wet suction.
  • Page 233 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 1. Open the flap A on the base of the water unit. 2. Allow the remaining water to be extracted completely. Press button B on the standard wet suction.
  • Page 234 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 5. Grease the O-ring C of the filter insert. Lubricants, see "Care, cleaning, and disinfecting agents" [ → 178].
  • Page 235: Emptying The Collector Of The Air Jet Pump

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.5 Components of the water unit 5.5.10 Emptying the collector of the air jet pump The air jet pump (Air Venturi) is an option available for the Compact water unit.
  • Page 236 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.5 Components of the water unit Operating Instructions (USA) INTEGO 3. Pour the excess water out of the container and collect the amalgam residues. Properly dispose of the amalgam residues together with the amalgam residues collected from the cuspidor and from the central suction sieve, see Cleaning the gold trap"...
  • Page 237: Sanitizing

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing Sanitizing Sanitizing effectively combats the reproduction of microorganisms in the water lines. Sanitizing using fresh water bottle Sanitizing with the fresh water bottle on the Compact or Comfort water unit.
  • Page 238: Sanitizing With The Fresh Water Bottle

    5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO 5.6.1 Sanitizing with the fresh water bottle If the Compact or the Ambidextrous water unit is fitted with a fresh water Sanitizing with the fresh water bottle with the Compact and Turn water unit bottle, manual sanitation must be performed: ●...
  • Page 239 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing 5. Unscrew the fresh water bottle from the holder on the water unit and empty the fresh water bottle completely. 6. Fill the fresh water bottle with approx. 0.4 to 0.5 liters of pure DENTOSEPT P.
  • Page 240 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO Stop  The program for sanitation starts. The key flashes orange on the touchscreen. The tumbler filling switches on and is supplied with DENTOSEPT P waterline treatment solution.
  • Page 241 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing Filling the fresh water bottle with water ✔ Refill water The display appears on the touchscreen. 1. Unscrew the fresh water bottle counterclockwise from the holder on the water unit and empty the fresh water bottle completely.
  • Page 242 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO 6. After you have flushed the last instrument, press the orange flashing Stop key.  The sanitation process is finished. The dental treatment unit is again ready for operation.
  • Page 243: Sanitizing With Waterline Treatment System

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing 5.6.2 Sanitizing with waterline treatment system Sanitizing must be performed: ● Regularly every 4 weeks when operating with the public drinking water supply or if stand-alone water supply is used more than 28 days...
  • Page 244 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO Opening the sanitation dialog via the touchscreen ✔ All instruments are in their holders. ✔ Start dialog is displayed on the touchscreen. Sub-dialog 1.
  • Page 245 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing Starting sanitation Start ➢ Touch the key. Start  The sanitation process starts. Error message: Refill with DENTOSEPT P waterline treatment solution Disinf...
  • Page 246 SPRAYVIT E: valve lever in the up position, locking knob in the down position). Also for INTEGO pro CS: Move the swivel arm of the instruments to be purged into the operating position so that the weight of the instrument hoses keeps them in this position.
  • Page 247 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing IMPORTANT Pinching the instrument hoses Be careful not to pinch the instrument hoses when inserting the instruments. With dental treatment units with the Ambidextrous option: convert the water unit to the left side so that the adapters on the water unit point towards the patient chair, see "Converting the Turn water unit for right-...
  • Page 248 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO Sanitation phase 3 – Treating water lines with DENTOSEPT P waterline treatment solution The water is pumped out of the water tank of the water unit via the tumbler filler.
  • Page 249 Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing Error message: Inserting instruments in the water unit If an instrument is accidentally deposited in its holder during the reaction Insert instruments into water unit...
  • Page 250 5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.6 Sanitizing Operating Instructions (USA) INTEGO Displays in case of incomplete sanitation The sanitation dialog detects whether the sanitation of all instruments and the tumbler filling was completed. Errors that occurred during sanitation...
  • Page 251: Display Sanitation Report

    Sirona Dental Systems GmbH 5 Care, cleaning and maintenance by the practice team Operating Instructions (USA) INTEGO 5.6 Sanitizing 5.6.3 Display sanitation report If the dental treatment unit is equipped with the EasyTouch comfort user Sanitation process with Comfort user interface interface, sanitation processes with a reaction time of at least 24 hours can also be displayed on the touchscreen.
  • Page 252: Fuse Of The External Device Connection

    5 Care, cleaning and maintenance by the practice team Sirona Dental Systems GmbH 5.7 Fuse of the external device connection Operating Instructions (USA) INTEGO Fuse of the external device connection The inlet connector remains live even when the power switch is turned off.
  • Page 253: Maintenance By The Service Engineer

    Sirona Dental Systems GmbH 6 Maintenance by the service engineer Operating Instructions (USA) INTEGO 6.1 Inspection and maintenance Maintenance by the service engineer Inspection and maintenance In order to ensure the operational safety and reliability of your dental treatment unit and to avoid damage due to natural wear, annual inspection and maintenance must be performed on your dental treatment unit.
  • Page 254: Maintenance Manual

    6 Maintenance by the service engineer Sirona Dental Systems GmbH 6.3 Maintenance Manual Operating Instructions (USA) INTEGO Maintenance Manual Keep this Maintenance Manual near your dental treatment unit. Any inspection and maintenance work as well as all safety tests are Documentation of the maintenance documented by the service engineer in the Maintenance Manual.
  • Page 255: Malfunctions

    [ → 222]. Check whether the public drinking water supply has the necessary water pressure, see the document on INTEGO / INTEGO pro installation requirements. Emergency pump operation Malfunctioning of pump sensors in the Inform your service technician. water unit.
  • Page 256 7 Malfunctions Sirona Dental Systems GmbH 7.3 Error Messages Operating Instructions (USA) INTEGO Code Error Description Measure Injection valve for waterline No waterline treatment solution is Inform your service technician. treatment solution defective added if the injection valve is defective. ApexLocator After switching on the dental...
  • Page 257: Remote Diagnosis

    Sirona Dental Systems GmbH 7 Malfunctions Operating Instructions (USA) INTEGO 7.4 Remote diagnosis Remote diagnosis Functional description With remote diagnosis, you enable the staff of your dental depot or our Customer Service Center, see "Contact data" [ → 10], to connect to the PC of your dental treatment unit.
  • Page 258: Spare Parts And Consumables

    Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO Spare parts and consumables Use only original accessories and original spare parts from Sirona! Please order the materials listed below from a specialized dental dealer. Care, cleaning, and disinfecting Care, cleaning agents, and disinfectants...
  • Page 259 Sirona Dental Systems GmbH 8 Spare parts and consumables Operating Instructions (USA) INTEGO Miscellaneous Cover, TS dentist element Cover For sealing the instrument holder of the TS dentist element REF 64 55 823 Silicone isolation sleeve for endodontics with the ApexLocator...
  • Page 260: Disposal

    9 Disposal Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO Disposal In accordance with Directive 2012/19/EU and national disposal regulations regarding old electrical and electronic devices, please be advised that such items must be disposed of in a special way within the European Union (EU).
  • Page 261: Overview Of All Function Keys

    Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.1 Fixed keys Overview of all function keys The following contains a brief description of the fixed keys on the dentist For Instructions for Use and assistant elements and the function keys on the touchscreen and to provide the reader with a quick overview of the significance of the symbols on the keys.
  • Page 262 10 Overview of all function keys Sirona Dental Systems GmbH 10.2 Start dialog Operating Instructions (USA) INTEGO 10.1.3 Assistant element Chair program S Mouth rinsing position with last-position memory function (programmable) Chair program 0 Entry/exit position (programmable) Tumbler filling on/off Flushing the cuspidor...
  • Page 263 Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.3 Start dialog for removed instruments Purging water lines automatically Auto Starts the autopurge function Sanitizing Starts the dental treatment unit sanitation program Stand-alone water supply Aqua The waterline treatment system switches to stand-alone water supply...
  • Page 264 10 Overview of all function keys Sirona Dental Systems GmbH 10.3 Start dialog for removed instruments Operating Instructions (USA) INTEGO Setting the automatic motor stop of the ApexLocator Apex Stop Apex Stop When the key is pressed, the – and + keys are displayed. The Apex automatic motor stop can be switched off or set to four different levels.
  • Page 265 Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.4 Integrated torque control 10.4 Integrated torque control Integrated torque control Activation of the integrated torque control function Calibrating the burr drive A calibration must be performed each time you change or lubricate the contra-angle handpiece.
  • Page 266 10 Overview of all function keys Sirona Dental Systems GmbH 10.5 Other dialogs Operating Instructions (USA) INTEGO 10.5 Other dialogs 10.5.1 Timer screen Time loop If the key is highlighted orange, the countdown will automatically be restarted when the set time has expired.
  • Page 267 Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.6 SIVISION program 10.5.5 Operating light setting program Sensor control for switching the operating light on/off If the key is highlighted orange, the operating light can be switched on/off or changed to the Composite function by a hand movement.
  • Page 268 10 Overview of all function keys Sirona Dental Systems GmbH 10.6 SIVISION program Operating Instructions (USA) INTEGO 10.6.3 SIDEXIS Start SIDEXIS SIDEXIS SIDEXIS is started on the PC. The keys belonging to the SIDEXIS PC application are displayed on the right side of the touchscreen:...
  • Page 269 Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.6 SIVISION program Relief display filter Image details with high contrast are displayed brighter or darker. Thus edges or contours within the image are clearly accentuated. The result is a relief-like image distortion.
  • Page 270 10 Overview of all function keys Sirona Dental Systems GmbH 10.6 SIVISION program Operating Instructions (USA) INTEGO Close current media window Close all media windows 10.6.4 SI Video Start SI Video SI-Video SI Video is started on the PC, if SIDEXIS is not installed on it. The keys...
  • Page 271 Sirona Dental Systems GmbH 10 Overview of all function keys Operating Instructions (USA) INTEGO 10.7 Setup program 10.7 Setup program 10.7.1 Date and time Date and time Date and Time Opens the setup program. Date 15 04 14 Time 12/24 hour display 12 h 10.7.2...
  • Page 272 10 Overview of all function keys Sirona Dental Systems GmbH 10.7 Setup program Operating Instructions (USA) INTEGO When this function is switched off, the display switches between a still or live image when the foot pedal is pressed. The knob on the camera is used to focus the image.
  • Page 273: Index

    Sirona Dental Systems GmbH Index Operating Instructions (USA) INTEGO Index Numerical Standardization, 103, 112, 115 with integrated torque control, 103 4-way foot switch, 173 Approvals, 22 4-way foot switch plate, 63 Armrest, 67 Articulating headrest, 33, 69 Accessories, 19, 258...
  • Page 274 Index Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO Chip blower, 61, 62, 84, 86 Deutscher Verein für Gas und Wasser (DVGW) = German Gas and Water Association, 23 Clean key, 182 Device ON/OFF switch, 57 Cleaning adapter, 210, 246...
  • Page 275 Sirona Dental Systems GmbH Index Operating Instructions (USA) INTEGO Fixed key Highspeed handpiece hose, 201 Chair programs, 122 Hose coding, 93 Clean, 182 Composite function, 123, 150 IEC socket, 54 Cuspidor flushing, 134 Immunosuppressed patients, 15 Flushing cuspidor, 123 Indication, 13...
  • Page 276 Index Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO Torque limitation, 102 Maintenance Service , 12 Turbine / air motor / other air-driven instruments, 91 Maintenance, cleaning, and disinfecting intervals, 176 Integrated torque control, 97 Manual measurement with the file clamp, 112...
  • Page 277 Sirona Dental Systems GmbH Index Operating Instructions (USA) INTEGO SaveMode and DropMode, 88 Sediment container, 229 Patient chair Self-test for chair drive, 57 Chair programs, 70, 75 Settings dialog, 60 Drive motors, 18 Setup key, 170 External device connector, 54...
  • Page 278 Index Sirona Dental Systems GmbH Operating Instructions (USA) INTEGO Suction sieve, 214 Suction system, 203, 210 Warning triangle, 255 Cleaning, 203 Warranty, 253 Cleaning agent mixture, 174 Water and air connection, 54 Suction hoses, 215 Water connection external device, 54...
  • Page 280 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe== péê~ÅÜÉW ÉåÖäáëÅÜ=ErpF mêáåíÉÇ=áå=dÉêã~åó aPRQPKOMNKMPKMOKOP NMKOMNS ûKJkêKW= NOO=VOS páêçå~=aÉåí~ä=póëíÉãë=dãÄe `çåí~Åí=áå=íÜÉ=rp^W páêçå~=aÉåí~äI=fåÅK SR=QT=SUS=aPRQP c~Äêáâëíê~≈É=PN QUPR=páêçå~=aêáîÉ lêÇÉê=kç aJSQSOR=_ÉåëÜÉáã `Ü~êäçííÉI=k`=OUOTP dÉêã~åó ïïïKëáêçå~KÅçã...

This manual is also suitable for:

Intego proIntego pro ambidextrous

Table of Contents