Pylontech Extra 2000 Product Manual page 10

Lithium-iron phosphate battery backup
Table of Contents

Advertisement

Extra 2000 Lithium Iron Phosphate Battery Backup Manual
ADD Switch (5)
ADD Switch: 4 ADD switches, to definite different address code for each
battery module when network cascade multiple battery, up to 8 addresses.
The coding and description see "Table 2-3 ADD Switch."
Table 2-3 ADD Switch
Coded Bit
1
2
ON
OFF
OFF
ON
ON
ON
OFF
OFF
Note:
The coded bits 1 to 4 in table separately represent ADD keys from left to right. (set up for
the "ON", down to "OFF"). The address of each device in accordance with the binary
coded bits, 1 is low, 4 is high, Table 2-3 Example 1-4 address coding, 5-8 address and
so on. If several Extra products cascading multiple network devices, the address
encoding 1 is the main battery, others are assistants.
LED Status Indicators (6,7,8)
RUN Lamp (No.6 Figure 2-1): green, long lighting when charging and flash
when discharging;
ALM Lamp (No. 7 Figure 2-1 7): red, flashes when alarm and long bright if
equipment failure or protected;
Battery capacity indicator (No. 8 Figure 2-1): 4 green lamps, each light
represent 25% of capacity. The four lights lit when capacity is 100%, if 75%,
the first left a lamp off, and the right three lights; if 50%, the left two lights out,
the right two lights; if 25 %, the left three lights off, the right one lights.
Table 2-4: LED Indicators Instructions
Battery
Protection
Statues
/ Alarm /
Pylon Technologies Co., Ltd. Confidential Proprietary
3
Veneer Sends, Computer Receives
4
Land
Address
3
4
OFF
OFF
(1)
OFF
OFF
(2)
OFF
OFF
(3)
ON
OFF
(4)
RUN
ALM
Pack
Master Pack, Corresponding with
Pack1
Pack2
Slave Pack1
Pack3
Slave Pack2
Pack4
Slave Pack3
Capacity LED
s
Description
RS232
Description
4

Advertisement

Table of Contents
loading