Installation Instructions

Installation Precautions

Panasonic does not accept any responsibility for accident or damage during installation if procedure
in this manual is not followed.
To installation personnel
Read the "Installation Instructions" thoroughly and then perform the operation correctly and safely.
Also, always read the "Read this First!" of this manual as they contain important information.
After the installation, give the "Operating Instructions <Basics>" to the customer to save for future use.
Ensure that the installation work
complies with the technical
standards governing electrical
equipment.
This unit is for indoor use only.
It cannot be used outdoors.
Avoid installation in a location where the
unit will be exposed to direct sunlight for
extended periods or near a cooling or
heating appliance.
Otherwise, deformation, discoloration,
malfunctioning and/or problems in operation
may result. Operate the unit where it will not
be splashed or sprayed by water.
Concerning the installation
location
Install the unit in a stable location which will
not be susceptible to shaking. If the unit is
installed in a location which is susceptible to
shaking, this will cause the unit's images to
shake in turn.
Install the unit after conferring in detail with
your dealer.
Install the unit on a ceiling that is strong
enough (such as a concrete ceiling).
If the unit is to be installed on a ceiling which
is not strong enough, reinforce the ceiling
sufficiently first.
Use the unit with an installation
where the unit is suspended
from an overhead surface or with
a stand-alone installation.
Do not use the unit on its side or tilted at an
angle.
[Note]
 Be absolutely sure to use the four bracket
mounting screws (M4) for mounting the
mount bracket. These are supplied with the
unit.
Do not use wood screws, nails, etc.
In the case of a concrete ceiling, secure
the unit using anchor bolts (for M4) or AY
plug bolts (for M4).
Recommended clamping torque M4 :
1.47 N · m {15 kgf · cm}
 The withdrawal strength of the mounting
location for each screw must be at least
461 N {47 kgf}.
 When mounting the unit on a ceiling made
of plasterboard, for instance, if it is not
strong enough to support its weight, either
reinforce the ceiling adequately or use the
WV-Q105A direct ceiling mount bracket,
which is sold separately.