Silicon Laboratories Si4704 Series Programming Manual page 89

Am/fm/sw/lw/wb receiver
Hide thumbs Also See for Si4704 Series:
Table of Contents

Advertisement

Property 0x1205. FM_RSQ_MULTIPATH_HI_THRESHOLD (Si4706/40/41/49 Only)
Sets the high threshold which triggers the RSQ interrupt if the Multipath level is above this threshold. The CTS bit
(and optional interrupt) is set when it is safe to send the next command. This property may only be set or read
when in power up mode. The default is 127.
Default: 0x007F
Step: 1
Range: 0-127
Bit
D15
D14
Name
0
0
Bit
Name
15:7
Reserved
6:0
MULTH
Property 0x1206. FM_RSQ_MULTIPATH_LO_THRESHOLD (Si4706/40/41/49 Only)
Sets the low threshold which triggers the RSQ interrupt if the Multipath level is below this threshold. The CTS bit
(and optional interrupt) is set when it is safe to send the next command. This property may only be set or read
when in power up mode. The default is 0.
Default: 0x0000
Step: 1
Range: 0-127
Bit
D15
D14
Name
0
0
Bit
Name
15:7
Reserved
6:0
MULTL
D13
D12
D11
D10
0
0
0
0
Always write to 0
FM RSQ Multipath High Threshold.
Threshold which triggers the RSQ interrupt if the Multipath is above this threshold.
Default is 127.
D13
D12
D11
D10
0
0
0
0
Always write to 0
FM RSQ Multipath Low Threshold.
Threshold which triggers the RSQ interrupt if the Multipath is below this threshold.
Default is 0.
Confidential Rev. 0.2
D9
D8
D7
D6
D5
0
0
0
Function
D9
D8
D7
D6
D5
0
0
0
Function
AN332
D4
D3
D2
D1
D0
MULTH[6:0]
D4
D3
D2
D1
D0
MULTL[6:0]