Analog Speed Input Scaling - Delta ASDA-A2 Series User Manual

High resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2 Series:
Table of Contents

Advertisement

Chapter 6 Control Modes of Operation|ASDA-A2 Series
Relevant parameters:
Accel / Decel Smooth Constant of Analog Speed
P1 - 06
SFLT
Command (Low-pass Filter)
Default: 0
6.3.3
Applicable Control Mode: S
Unit: msec
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal

6.3.4 Analog Speed Input Scaling

The analog voltage between V_REF and GND determines the motor speed command. Using with
parameter P1-40 (Max. Analog Speed Command) can adjust the speed control ramp and its range.
6-28
Target Speed
5000rpm
3000rpm
-10
-5
5
-3000rpm
-5000rpm
SFLT
The speed control ramp is
determined by parameter P1-40
Analog Input Voltage (V)
10
Address: 010CH, 010DH
Related Section: Section
Revision April,2010