D R A I N P U M P – M O D E L 3 1 5 I P
This ice maker comes with a built-in drain pump.
The drain and inlet water tubes must be
plumbed before connecting to the ice maker. An
air gap will likely be required between the ice
maker drain tube and the drain/waste receptacle.
A stand pipe with a trap below it would be
acceptable for the drain/waste receptacle. Refer
to the illustrations below.
IMPORTANT NOTE: Poor drainage will cause a
I N S T A L L A T I O N
high rate of ice melting in the bin.
Refer to the
installation instruc-
tions shipped with
each Sub-Zero
product for detailed
specifications.
I N S T A L L A T I O N S P E C I F I C A T I O N S
Model 315IP – Drain Pump
68
3 mm
SHUT-OFF
VALVE
WATER
INLET TUBE
WATER
DRAIN
FILTER
TUBE
AIR GAP
DEVICE
387 mm
MIN.
TOP VIEW
D O O R P A N E L – M O D E L 3 1 5 I P
It is important to understand the differences in
mounting any wood panel to the Model 315IP .
Refer to the installation instructions packaged
with the unit to understand how the panel is
installed. It does not require a 6 mm backer.
Door panel dimensions are 381 mm wide by
772 mm high and must be a minimum of 16 mm
thick. The maximum door panel weight is 7 kg.
No handle recess is required.
609 mm
SHUT-OFF
VALVE
AIR GAP
DEVICE
876 mm
NOMINAL
857 mm
DRAIN
TUBE
MIN.
WATER
INLET TUBE
WATER
387 mm
MIN.
FILTER
FRONT VIEW