Space Required - aerauliqa QR280A Installation, Use And Maintenance Manual

Table of Contents

Advertisement

24
23
22
21
20
T
B
R
P
A
N
M
L
K
J
H
G
F
E
D
C
fig. 3.b Connections in LEFT and RIGHT orientation - QR400A e QR550A.
B
A
To set the RIGHT orientation of the machine:
24
23
22
21
20
• Modify the orientation on the CTRL-DSP (§ 7.2 - Installer menu: 3 Machine Orientation).
• For the QR400 and QR550 units move the F7 filter from the left to the right side.
• Replace the ducting connection label on the top of the casing and the water drainage label on the bottom of the casing with
those supplied with this installation manual.

3.4 space required

Make sure that enough space is left around the unit to allow easy maintenance (access to filters, terminal box and removal of the
side and front inspection panels).
3.5 Rating label
fig.3.c Rating label
4 tRAnsPoRt And stoRAGe
Make sure that specific warnings and cautions in Chapter 2 "Precautions" are carefully read, understood and applied!
The appliance is delivered in one carton box.
The appliance should be stored and transported in such a way that it is protected against physical damage that can harm spigots,
casing, display etc...
It should be covered so that dust, rain and snow cannot enter and damage the unit and its components.
5 instAllAtion
Make sure that specific warnings and cautions in Chapter 2 "Precautions" are carefully read, understood and applied!
This section describes how to install the unit correctly.
the unit must be installed according to these instructions.
5.1 unpacking
Verify that the unit (and eventual accessories) delivered is according to order before starting the installation. Any discrepancies
from the ordered equipment must be reported to the supplier.
5.2 Where/how to install
• All QR units are meant for indoor installation in a heated space.
• Mount the unit on flat surface (wall).
19
18
17
16
15
14
13
12
C
D
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
E
F
SE NON SPECIFICATO:
FINITURA:
QUOTE IN MILLIMETRI
FINITURA SUPERFICIE:
TOLLERANZE:
LINEARE:
ANGOLARE:
NOME
FIRMA
DATA
DISEG.
VERIF.
APPR.
FABB.
Qual.
MATERIALE:
PESO:
11
10
9
8
7
6
5
4
WARninG
WARninG
3
2
1
T
R
P
QR400A - QR550A
N
A
Intake air from outside
M
B
Exhaust air to outside
C
L
Supply air to inside
LEFT
D
Extract air from inside
K
E
Winter condensation drainage
J
F
Summer condensation drainage
H
A
Extract air from inside
G
B
Supply air to inside
F
C
Exhaust air to outside
E
RIGHT
D
Intake air from outside
D
E
Summer condensation drainage
C
F
Winter condensation drainage
B
INTERRUZIONE
NON SCALARE DISEGNO
REVISIONE
BORDI NETTI
TITOLO:
QR
A
fig-8
N. DISEGNO
A0
SCALA:1:1
FOGLIO 1 DI 1
3
2
1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QR280A and is the answer not in the manual?

This manual is also suitable for:

Qr400aQr550a

Table of Contents