6 coMMissioninG
6.1 setting fan speed
The speed of the unit can be adjusted during installation according to required ventilation rate.
figures 6. a-d-g below show performance curve at different settings of the 0-10V signal to the motors. Consumption refers to
the 2 motors.
tables 6. b-e-h indicate the efficiency of the heat exchanger and of the condensation produced in different climatic conditions,
to help the installer or the designer of the ventilation system to decide if to connect one or both condensation drainages.
High production of condensation is the direct consequence of a high efficiency level as well as of the humidity rate.
tables 6. c-f-i indicate the sound level at the different speeds.
QR280A
600
550
500
450
400
350
300
250
200
150
100
B
50
A
I
0
0
20
40
60
EXTERNAL
T (°C)
R.H. (%)
T (°C)
-18
60
-18
70
-18
80
-10
60
-10
70
-10
80
0
50
0
60
0
70
10
50
10
60
10
70
35
60
35
70
35
80
40
60
40
70
40
80
table 6.b Thermal efficiency of the heat exchanger and average production of condensation water. Preliminary data.
G
F
E
D
C
V
II III
IV
80
100
120
140
160
Airflow - m
Working point
W
I
11,9
II
16,5
III
23,4
IV
32,8
V
47,7
(1)
Thermal efficiency of the unit.
INTERNAL
50m
/h
3
ƞ (%)
R.H. (%)
H
O (kg/h)
2
20
30
95,3
20
40
96,0
20
50
96,8
20
30
95,1
20
40
96,1
20
50
96,8
20
30
94,6
20
40
95,3
20
50
95,8
20
40
94,0
20
50
93,9
20
60
94,8
26
50
94,4
26
55
95,7
26
60
97,4
26
50
96,4
26
55
97,5
26
60
98,5
180
200
220
240
/h
3
m
/h
SPI (W/m
/h)
3
3
54
0,2204
76
0,2183
97
0,2407
119
0,2761
140
0,3397
100m
/h
3
ƞ (%)
H
O (kg/h)
2
0,16
92,2
0,29
0,22
92,6
0,42
0,28
94,0
0,55
0,10
91,3
0,18
0,16
92,5
0,30
0,21
93,6
0,41
0,01
88,8
0
0,06
90,4
0,10
0,11
92,8
0,20
0
88,8
0
0
88,9
0
0,02
90,3
0,03
0
88,8
0
0,04
92,2
0,08
0,09
95,0
0,18
0,08
92,6
0,15
0,14
94,9
0,27
0,20
97,2
0,38
Curve
A (min)
B
C
D
E
F
G (max)
fig. 6.a Intake curve according to Reg.
1253/2014 (ErP).
260
280
300
ƞt %
(1)
86
86
85
84
83
150m
/h
200m
3
3
ƞ (%)
ƞ (%)
H
O (kg/h)
H
2
2
89,0
0,41
85,0
90,0
0,61
86,8
90,6
0,79
88,0
87,6
0,24
83,6
89,6
0,42
87,1
91,2
0,59
88,1
84,6
0
80,1
86,6
0,13
83,4
89,5
0,28
86,7
84,3
0
80,3
84,4
0
81,2
85,1
0,03
80,9
84,4
0
82,0
88,9
0,10
85,4
93,1
0,26
91,6
89,9
0,19
85,7
92,6
0,39
91,0
95,4
0,57
93,3
W
m
3
Speed %
max
max
23
9
36
30
17
88
46
33
139
60
41
153
77
51
172
92
100
230
100
160
281
/h
250m
/h
3
ƞ (%)
O (kg/h)
H
O (kg/h)
2
0,51
81,5
0,58
0,78
83,3
0,88
1,02
84,5
1,16
0,29
80,1
0,32
0,53
83,6
0,60
0,76
84,6
0,86
0
76,6
0
0,13
79,9
0,15
0,34
83,2
0,38
0
76,8
0
0
77,7
0
0,01
77,4
0,01
0
78,5
0
0,11
81,9
0,12
0,33
88,1
0,37
0,23
82,2
0,26
0,50
87,5
0,56
0,73
89,8
0,83
/h
Need help?