Completing the Installation
Caution: Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.
b With your free hand, move the parking tab in a clockwise direction
until it stops in the "unparked" position. When in the correct
position, the parking tab is removed completely from the interior of
the module and will not accidentally swing into the path of the
robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.
2 Reinstall the tape drives to the library.
3 Cable your library as necessary, including the power supplies, following the
instructions provided in the "Cabling the Library" section of the
User's Guide
.
4 Power on the library:
a Turn ON each power supply, using the switch on the rear of the power
supply.
b Press the power button located on the front door of the library's control
module.
When you power on the library, the library performs a self-test to ensure
that all of its parts are functioning properly. All tape drives and
partitions are brought online.
Quantum Scalar i500: Rackmount Kit Installation
6-01492-04 Rev A
December 2013
Scalar i500
19