Water Connection; High Pressure Connection - Kranzle therm 890 Operating Manual

Table of Contents

Advertisement

Commissioning
Secure the machine by applying the brake.
Open the right cover of the machine (without
chimney) and check the oil level of the high
pressure pump.
Do not start the machine if there is no oil on the
dipstick. Fill oil if necessary.
Use EL heating oil (DIN 51603) or diesel fuel only
Unsuitable fuels, such as petrol, may not be used (danger of
explosion)

Water connection

Connect the machine to a water tap using a hose of at least 1/2" and turn on the tap.
The water tank in the machine fills up. When the tank is full, the built-in float valve
closes the water inlet.
Use clean water only!
Follow the instructions of the local water supply utility.
Connection of the machine to drinking water mains must be in
accordance with EN 61 770.

High pressure connection

Connect the high pressure hose to the handgun.
Unwind the hose so that it is free of loops and connect it to the handgun and the
machine.
Check that all screw-type connections are pressure-tight. Leaks
from gun, high pressure hose or hose drum must be eliminated
immediately. Leakage leads to increased wear.
Commissioning
Fill the fuel tank with light heating oil prior to
use.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Therm 11602175