September 28, 2004

Electrical installation

Electrical installation should only be attempted by a qualified electrician. Electrical connection must comply
with all applicable national and local codes.

Guidelines for electrical installation

Inspect all internal sign cabling for proper connection and seating.
All power wiring must be from circuit breaker-protected lines.
A two-pole disconnect device must be installed in the building wiring for each branch circuit supplying
the sign.
The sign must be properly grounded according to the applicable codes (for example, NEC Article 250 and
600, and IEEE 1100-1999).
Run separate conduits for signal wires (for example, RS232, RS485) and for power wires. However, fiber
optic wire may be run in the same conduit with power wires.
All electrical connections must be watertight.
Use minimum 80° C copper wire only.
Utiliser uniquement un fil en cuivre pouvant supporter 80° C minimum.
Torque terminals to a minimum of 7 in/lbs and a maximum of 10 in/lbs.
Serrer les bornes à 0,79 N/m minimum, mais pas à plus de 1,13 N/m.

Run power to the sign

1.
Use a 5/32-inch hex tool to loosen the hex screws on each of the sign's wireway doors. Then open each
wireway door:
16
WARNING
Hazardous voltage.
Contact with high voltage
may cause death or serious
injury.
Always disconnect power to
unit prior to servicing.
SM1000A
5/32-inch hex tool
(pn 6811-7076)
AlphaEclipse 3600 Series A Sign Installation Instructions (9711-8001C)
WARNING
Disconnect main
power before
servicing!
E a c h s e c t i o n ' s p o w e r s w i t c h
c o n t r o l s t h a t s e c t i o n o n l y !