AlphaEclipse 3600 Series A Sign Installation Instructions (9711-8001C)

Temperature protection

If the temperature inside of a sign cube exceeds . . .
110°F (43°C) — the cube's fans will start. When the temperature falls below 80°F (27°C), the fans will stop.
170°F (77°C) — power is removed from cube components except the fans. When the temperature falls
below 140°F (60°C), power will be applied again.

Equipment symbols

Preventing electrostatic discharge damage

This equipment contains components that may be damaged by "static electricity", or electrostatic discharge.
To prevent this from happening, be sure to follow the guidelines in Adaptive Tech Memo 00-0005, "Preventing
Electrostatic Discharge (ESD) Damage," available on our Web site at http://www.adaptivedisplays.com.

EMI compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with installation guidelines, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference, in which case the user will be required
to correct the interference at his own expense.