Step 16
Check to ensure the ignitor (14) is located
properly.
- Ignitor probe (14) should be
1/8" under the hood.
- Ignitor probe (14) should be 3/16" away
from flame sensor (15).
- Probe should be bent so that the tip of
the probe sparks only against the hood
of the pilot.
- DO NOT TWIST IGNITOR
WIRE OR IT MAY BREAK
FROM CERAMIC BASE.
DO NOT USE A
BROKEN IGNITOR.
Step 17
Add the valve bracket (27) to the base of the
Pilot Pro Valve (11) using:
- x2 Screws #10-24 x 3/8" (28)
1018039-B
INSTALLATION
1 /
8 "
View from
above
Page 16
15
14
15
14
28
28
3 /
16 "
11
27